Harman Kardon DPR 1005 (serv.man13) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 9 of 41 -
Order
No.
26088
7.1
Operating conditions:
Sine wave 1000Hz input, set to 1/8 of maximum output power for Front,
Center, Surr. and Surr.Back channels.
Center, Surr. and Surr.Back channels.
U
=
207,0
V, I
=
1,12
A, P
=
136
W,
Pout =
2 x 8,70
W
(F)
1 x 9,19
W
(C)
2 x 8,70
W
(S)
2 x 8,78
W
(S/B)
U
=
253,0
V, I
=
0,96
A, P
=
142
W,
Pout =
2 x 8,70
W
(F)
1 x 9,19
W
(C)
2 x 8,70
W
(S)
2 x 8,78
W
(S/B)
LSL
= 8
Ω x 7 channels ( Front: 2, Center: 1, Surround: 2, Surround Back: 2 )
Loudspeaker system(s)
Right and Left for Front,
One for Center,
Right and Left for Surround Back,
Right and Left for Surround channels.
Marking of loudspeaker terminals
SPEAKERS 8
Ω :
CENTER, FRONT L / R,
SURR. L / R, SBL / MULTI L / R.
U =
253,0
V
4 Ohm
8 Ohm
16 Ohm
6
Ohm
Left Right
Left
Right
Left Right
Left Right
Measured output voltage in Vp
F) 33,4
C) 34,3
S) 33,4
S/B) 33,5
C) 34,3
S) 33,4
S/B) 33,5
F) 33,4
C) -
S) 33,4
S/B) 33,5
C) -
S) 33,4
S/B) 33,5
Measured output power in W
F) 69,6
C) 73,5
S) 69,6
S/B) 70,2
C) 73,5
S) 69,6
S/B) 70,2
F) 69,6
C) -
S) 69,6
S/B) 70,2
C) -
S) 69,6
S/B) 70,2
Measured mains power in W
660
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible
parts
parts
(see table next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table next page)
P
7.1.3
Temperature rise of parts acting as
a support or as a mechanical
barrier
a support or as a mechanical
barrier
(see table next page)
P
7.1.4
Temperature rise of windings
(see table next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table next page)
P
-
IEC 60065, 6th edition : 1998
-
- Page 10 of 41 -
Order
No.
26088
HEATING
∆t = ( R2 - R1) x (234,5 + t1) - (t2 - t1)
R1
R1
P
t1 =
23,0 °C
23,0 °C
t2 =
23,4 °C
23,9 °C
Test voltage
207 V
253 V
Winding
R1/
Ω R2/Ω
∆t measured
∆t allowed *)
Insulation
class
class
T101 winding at 207 V
679
833
58,0
85
Class E
T101 winding at 253 V
679
876
73,8
85
Class E
Other measured parts
∆t measured
at 207V
at 207V
∆t measured
at 253V
at 253V
∆t allowed *)
Linear transformer, T101 core
47,8
56,5
85
Switching transformer, T102 core
25,8
27,8
70
Switching transformer, T102 coil
28,5
30,4
70
Switching transformer, T103 core
27,3
29,2
70
Switching transformer, T103 coil
28,8
31,0
70
Switching transformer, T201 core
26,6
28,1
70
Switching transformer, T201 coil
27,3
28,8
70
Switching transformer, T202 core
28,2
30,4
70
Switching transformer, T202 coil
28,4
30,7
70
Line chock, T203 coil
28,2
30,7
70
Reactor, PT01 coil
17,8
17,2
70
Line filter, LF101 coil
15,1
15,9
70
Line filter, LF102 coil
14,8
15,7
70
PFC, L206 coil
21,5
23,2
70
Diode, BD101 body
25,9
27,3
-
PWB near BD101
24,8
26,5
85
PWB near D215
34,5
39,4
85
HS104 heat-sink
26,7
28,6
-
E. Capacitor, C107 body
22,7
25,0
85°C
PWB near Q105
26,8
30,0
85
PWB near U101
27,3
30,7
85
-
IEC 60065, 6th edition : 1998
-
- Page 11 of 41 -
Order
No.
26088
HEATING (continued)
P
Other measured parts (continued)
∆t measured
at 207V
at 207V
∆t measured
at 253V
at 253V
∆t allowed *)
HS102 heat-sink
28,7
32,9
-
Top enclosure above Amp. Module
13,1
12,7
40
Top enclosure above SMPS
15,3
17,1
40
Amp. Module body
26,6
25,7
-
Appliance inlet body
13,7
13,2
60
Switch button (standby / on)
1,4
1,5
50
Comments
No other parts were observed to create any hazard due to temperature rise.
P
*) Temperature rise limits for Singapore is 10K less.
P
7.2
Softening temperature of insulating
material supporting parts
conductively connected to the mains
carrying a current > 0,2 A at least
150
material supporting parts
conductively connected to the mains
carrying a current > 0,2 A at least
150
°C
No temperatures measured during heating test and fault
cond. tests requires this test (7.2) to be performed.
cond. tests requires this test (7.2) to be performed.
N
Tested parts
Temperature
under normal
operating con-
ditions (°C)
under normal
operating con-
ditions (°C)
Temperature
under fault
conditions
(°C)
under fault
conditions
(°C)
Softening
Temperature
(°C)
Temperature
(°C)
-
IEC 60065, 6th edition : 1998
-
- Page 12 of 41 -
Order
No.
26088
8 CONSTRUCTIONAL
REQUIREMENTS WITH REGARD
TO THE PROTECTION AGAINST
ELECTRIC SHOCK
TO THE PROTECTION AGAINST
ELECTRIC SHOCK
P
8.1
Conductive parts covered by
lacquer, paper, untreated textile
oxide films and beads etc.
considered to be bare
lacquer, paper, untreated textile
oxide films and beads etc.
considered to be bare
Considered
P
8.2
Shock hazard when changing
voltage setting device, fuse-links or
handling drawers etc.
voltage setting device, fuse-links or
handling drawers etc.
Operation “By hand” not possible
N
8.3
Insulation of hazardous live parts not
provided by hygroscopic material
provided by hygroscopic material
No hygroscopic materials
N
8.4
Risk of electric shock from
accessible parts, including when
covers are removed by hand.
accessible parts, including when
covers are removed by hand.
No cover removable by hand.
N
8.5
Class I equipment
Class II equipment
N
Basic insulation between hazardous
live parts and earthed accessible
parts
live parts and earthed accessible
parts
N
Resistors bridging basic insulation
complying with 14.1 a)
complying with 14.1 a)
N
Capacitors bridging basic insulation
complying with 14.2.1 a)
complying with 14.2.1 a)
N
Basic insulation bridged by
components complying with 14.3.4.3
components complying with 14.3.4.3
N
Protective earth contact
N
8.6
Class II equipment and Class II
constructions within Class I
equipment
constructions within Class I
equipment
P
Reinforced or double insulation
between hazardous live parts and
accessible parts
between hazardous live parts and
accessible parts
Double/Reinforced insulation complies with
requirements specified in clause 10 and 13.
requirements specified in clause 10 and 13.
P
Components bridging reinforced or
double insulation complying with
14.1 a) or 14.3
double insulation complying with
14.1 a) or 14.3
The apparatus have isolating transformer(s).
P
Basic and supplementary insulation
each being bridged by a capacitor
complying with 14.2.1 a)
each being bridged by a capacitor
complying with 14.2.1 a)
N
Reinforced or double insulation
being bridged by 2 capacitors in
series complying with 14.2.1 a)
being bridged by 2 capacitors in
series complying with 14.2.1 a)
N
Reinforced or double insulation
being bridged by a single capacitor
complying with 14.2.1 b)
being bridged by a single capacitor
complying with 14.2.1 b)
Y
1
capacitor, C104, C105, C119, C127 and C128;
inside the enclosure.
P