EMC - CB Certificate
Brand
Device
Audio
File
dpr-1005-sm13.pdf
Date

Harman Kardon DPR 1005 (serv.man13) EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 33 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
ANNEX A, ADDITIONAL 
REQUIREMENTS FOR 
APPARATUS WITH PROTECTION 
AGAINST SPLASHING WATER  
Not intended for outdoor use. 
A.5.1 
j) Marked with IPX4 (IEC 60 529), 
5.4.1 a) does not apply  
 
A.10.2.1 
Enclosure provides protection 
against splashing water  
 
A.10.2.2 
Humidity treatment carried out for 
7 days  
 
 
ANNEX B, APPARATUS TO BE 
CONNECTED TO THE 
TELECOMMUNICATION 
NETWORKS  
Not intended for telecommunication networks 
B.5.4.1 
e) Where the separation of TNV 
circuits from other circuits relies on 
protective earthing the instructions 
make it clear that protective earthing 
is essential  
 
B.8.1 
TNV circuits separated from the  
mains circuit and from hazardous  
live parts by either: 
 
 
 
 
 
a) double or reinforced insulation  
 
 
b) basic insulation with earthed 
protective screening  
 
B.8.2 
TNV circuits separated from circuits 
other than those in B.8.1 and from 
accessible conductive parts by basic 
insulation meeting the requirements 
for clearances and creepage 
distances for the voltages concerned 
 
B.9.1.1 
TNV circuit terminals contacts which 
cannot be touched by probe B.1, 
exempt from the requirements 
inaccessible terminal contacts in 
9.1.1  
 
B.10.1 
Insulation between TNV terminals 
and antenna terminals (including 
interconnection terminals which may 
be connected to equipment with 
antenna terminals) withstands the 
50 discharges of 10.1  
 
B.14.12 
Surge suppressors between TNV 
circuits and other parts of the 
equipment have breakdown voltage 
at least 1,8 times the mains voltage  
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 34 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
LIST OF CRITICAL COMPONENTS 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
T101 Power 
transformer 
 
Bobbin  
Bobbin cap. 
Thermal fuse 
Woojin Elecom. 
 
 
LG Chemical Ltd. 
E I Dupont. 
Anzen Dengu Co. 
TPW-4102 
 
 
GP-2301F(#). 
101F 
K12 
230V, Class E 
 
 
V-0, 150°C 
V-2, 130°C 
1A/250V, 130°C
 
IEC60065 
clause 14.3 
 
UL94 
UL94 
IEC60691 
1.) 
 
 
UL, 
E67171
UL, 
E41938
VDE 
T102 Switching 
transformer 
 
Bobbin Mtl. 
Keosan Telecom. 
 
 
BAKELITE AG. 
KJP-10013T2 
 
 
PF2736 
Class A 
 
 
V-0, 150°C 
IEC60065 
clause 14.3 
 
UL94 
1.) 
 
 
UL, 
E61040
T103 Switching 
transformer 
 
Bobbin 
Keosan Telecom. 
 
 
BAKELITE AG. 
KJP-7013T1 
 
 
PF2736 
Class A 
 
 
V-0, 150°C 
IEC60065 
clause 14.3 
 
UL94 
1.) 
 
 
UL, 
E61040
T201, 
T202 
Switching 
transformer 
 
Bobbin 
Keosan Telecom. 
 
 
BAKELITE AG. 
KJP-10013T3 
 
 
PF2736 
Class A 
 
 
V-0, 150°C 
IEC60065 
clause 14.3 
 
UL94 
1.) 
 
 
UL, 
E61040
T203 
Sensing Chock,  
transformer 
 
Base Material 
Keosan Telecom. 
 
 
BAKELITE AG. 
10013 N/C 
 
 
PF2736 
Class A 
 
 
V-0, 150°C 
IEC60065 
clause 14.3 
 
UL94  
1.) 
 
 
UL, 
E61040
LF101, 
LF102 
Line Filter 
 
Core cover 
Woojin Elecom. 
 
Sam Yang Co., Ltd. 
38PHI 
 
1500GN-30 
Class A 
 
V-0, 140°C 
IEC 60065 
 
UL 94 
1.) 
 
UL, 
E121254
PT01 Reactor 
 
Bobbin 
Bobbin cap. 
Power Technics Co. 
 
Asahi Kasei Chem. 
Asahi Kasei Chem. 
RE-2500 
 
1300S 
1300S 
Class A 
 
V-2, 105°C 
V-2, 105°C 
IEC 60065 
 
UL 94 
UL 94 
1.) 
 
UL, 
E48285
UL, 
E48285
F101 
Mains fuse 
Orisel Co., Ltd. 
Littelfuse. 
Suzhou Littelfuse. 
55T 
215 
215 
T8A H 250V 
IEC 60127
 
VDE 
VDE 
VDE 
F401 Outlet 
fuse 
alt. 
alt. 
alt. 
Orisel Co., Ltd. 
Littelfuse. 
Schurter AG. 
Sun Electronics. 
50T 
218 
SFT 
5T 
T2A L 250V 
IEC 60127
 
VDE 
VDE 
VDE 
VDE 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 35 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
LIST OF CRITICAL COMPONENTS (continued)
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
C101,  
C103 
X - Capacitor 
alt. 
alt. 
alt. 
alt. 
alt. 
alt. 
alt. 
Pilkor Electronics. 
Pilkor Electronics. 
Iskra Kondenzatorji. 
Iskra Kondenzatorji. 
Sun il Electronics. 
Okaya Electric Inc. 
Yuchang Electronics.
Ultra Tech Xiphi. 
PCX2 335M 
PCX2 335 
KNB1530 
KNB1560 
435D 
RE104 
WBU1942 
HQX 
1.0uF 275V 
X2 
IEC60384-14, 
2
nd
 ed. 
VDE 
VDE 
VDE 
VDE 
VDE 
VDE 
VDE 
VDE 
C102 
X - Capacitor 
alt. 
alt. 
alt. 
alt. 
alt. 
alt. 
alt. 
Pilkor Electronics. 
Pilkor Electronics. 
Iskra Kondenzatorji. 
Iskra Kondenzatorji. 
Sun il Electronics. 
Okaya Electric Inc. 
Yuchang Electronics.
Ultra Tech Xiphi. 
PCX2 335M 
PCX2 335 
KNB1530 
KNB1560 
435D 
RE104 
WBU1942 
HQX 
0.47uF 275V 
X2 
IEC60384-14, 
2
nd
 ed. 
VDE 
VDE 
VDE 
VDE 
VDE 
VDE 
VDE 
VDE 
C104, 
C105, 
C119 
Y-capacitor 
alt. 
alt. 
alt. 
alt. 
alt. 
Netron Tech. 
Samwha Cap. 
Du San Industrial. 
Murata Mfg. 
Dae Myung Elect. 
JYH CHUNG 
AD 
SD 
NK 
KX 
DG 
JD 
1000pF 250V 
Y1 
IEC60384-14, 
2
nd
 ed. 
VDE 
VDE 
VDE 
VDE 
VDE 
VDE 
C127, 
C128 
Y-capacitor 
alt. 
alt. 
alt. 
alt. 
alt. 
Netron Tech. 
Samwha Cap. 
Du San Industrial. 
Murata Mfg. 
Dae Myung Elect. 
JYH CHUNG 
AD 
SD 
NK 
KX 
DG 
JD 
470pF 250V 
Y1 
IEC60384-14, 
2
nd
 ed. 
VDE 
VDE 
VDE 
VDE 
VDE 
VDE 
C403 
(SK42 across)
 
X-Capacitor
  
alt. 
alt. 
alt. 
alt. 
alt. 
Netron Tech. 
Samwha Cap. 
Du San Industrial. 
Murata Mfg. 
Dae Myung Elect. 
JYH CHUNG 
AA 
SC 
NU 
KH 
DE 
JY 
4700pF 250V 
X1/Y2 
IEC60384-14, 
2
nd
 ed. 
VDE 
VDE 
VDE 
VDE 
VDE 
VDE 
SW80 
Mains switch 
Alps Electric Co Ltd. 
KV1 
8A/128A 250V 
IEC 61058 
IEC60065 
VDE 
RL101 Mains 
relay Matsushita 
Electric Works. 
ALE15B12 
16A 277V 
IEC 61058
 
VDE 
SK41, 
SK42 
Outlet relay 
Tyco Electronics EC.
SDT-112DMR 
8A/120A 250V 
IEC 61058 
IEC60065 
SEMKO 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 36 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
LIST OF CRITICAL COMPONENTS (continued)
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
NJ42 Mains 
 
socket-outlet 
Dae Ryung 
Electronics Co., Ltd. 
A3-04-D007 
2.5A / 250V 
IEC60884-1
NEMKO 
NJ41 A
ppliance inlet
 Zhangjiagang 
 
Huajie Electronics 
SA-4S 10A/250V~ 
IEC60320 
VDE 
R102 
Discharge 
resistor 
Various 
Various 
1 M
Ω, 1/2 W 
- 1.) 
After the 
mains fuse,
F101
 
VR101 Varistor 
 
 
alt. 
Hiel Corporation. 
 
 
Various 
SVR471D14A 
TNR12G471K 
 
Various 
470Vdc,  
4500Ap(8/20us) 
 
Min. 470Vdc, 
4500Ap(8/20us) 
- 1.) 
 
After the 
mains fuse,
F101
 
PC101, 
PC102 
Optocoupler 
alt. 
alt. 
alt. 
alt. 
alt. 
alt. 
alt. 
alt. 
Vishay Semicond. 
Toshiba Semi. 
Sharp Corp. 
COSMO Elect. 
COSMO Elect. 
Lite-On Electronic. 
Everlight Elect. 
NEC Corp. 
Kodenshi Corp. 
TCET1103 
TLP721 
PC12.. 
KPC817 
KP1010 
LTV-817… 
EL817 
PS-2561-1 
PC-17K1 
- Viso ; >3000V 
- Int. dist.: >4mm 
- Ext. dist.: >6mm  
IEC60950 FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
C121 
Large Volume 
Capacitor 
(>1750 mm³)
 
Seoryong Elect. 
ME 
4.7uF 250V, 
Category B 
IEC 60384-1, 
4.38. 
1.) 
AMP module 
D2AUDIO. 
GR70-7 
70W x 7 Ch. 
(
AMP circuits is 
enclosed fully by 
the metal with V-0 
decoration cover)
 
- 1.) 
 PCB 
base 
material 
Various 
Various 
Min 94V-1 
UL 796 
UL 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
Page of 53