IEC 60065, 6th edition : 1998
 - 
- Page 37 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
FAULT CONDITION TESTS  
P
Ambient temperature  
 25,5 °C 
Rated voltage  
230V~ 
Remarks  
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
BD101 
S-c 
253 
AC - (+) 
1 sec. 
F101 
F101 opened immediately. 
No hazard. 
BD101 
S-c 
207 
AC - (+) 
1 sec. 
F101 
F101 opened immediately. 
No hazard. 
C106 
S-c 
253 
1 sec. 
F101 
F101 opened immediately. 
No hazard. 
C106 
S-c 
207 
7 sec. 
F101 
3,60 A 
F101 opened After 7 sec. 
No hazard. 
Q102 
S-c 
253 
S – D 
1 sec. 
F101 
F101 opened immediately. 
Q103, ZD102 damaged. 
No hazard. 
Q102 
S-c 
253 
D - G 
1 sec. 
F101 
F101 opened immediately. 
Q103, ZD101 damaged. 
No hazard. 
U101 
S-c 
253 
Pin 2 - 4 
1 sec 
F101 
F101 opened immediately. 
U101, ZD105 damaged. 
No hazard. 
C108 
S-c 
253 
30 min 
F101 
1,20 A 
Normal operated. 
Input current stabilised at 0,86A. 
R123 opened. 
No hazard. 
BD202 
S-c 
253 
AC – (+) 
20 min 
F101 
0,99 A 
Normal operated. 
T101 primary winding heated up to
136K and thermal fuse opened 
after 15 min. 
Input current stabilised at 0,15 A. 
Dielectric strength test OK. 
No hazard. 
C218 
S-c 
253 
15 min 
F101 
0,98 A 
Normal operated. 
T101 primary winding heated up to
106K and thermal fuse opened 
after 10 min. 
Input current stabilised at 0,15 A. 
Dielectric strength test OK. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 38 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
FAULT CONDITION TESTS (Continued) 
P
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
BD201 
S-c 
253 
AC – (+) 
20 min 
F101 
0,97 A 
Normal operated. 
T101 primary winding heated up to
121K and thermal fuse opened 
after 16 min. 
Input current stabilised at 0,15 A. 
Dielectric strength test OK. 
No hazard. 
C220 
S-c 
253 
20 min 
F101 
0,14 A 
Unit shut down immediately. 
T101 primary winding heated up to
115K and thermal fuse opened 
after 25 min. 
Input current stabilised at 0,14 A. 
Dielectric strength test OK. 
No hazard. 
D206 
S-c 
253 
A - C 
40 min 
F101 
1,60 A 
Unit shut down after 25 min. 
Input current stabilised at 0,15 A. 
D206, T102 damaged and 
C210, C220, C211 vented. 
Dielectric strength test OK. 
No hazard. 
C216 
S-c 
253 
10 min 
F101 
0,14 A 
Unit shut down immediately. 
Input current stabilised at 0,14 A. 
No component damaged. 
No hazard. 
D207 
S-c 
253 
A - C 
10 min 
F101 
1,17 A 
Unit shut down after 4 min. 
Input current stabilised at 0,11 A. 
T102 and D207 damaged. 
Dielectric strength test OK. 
No hazard. 
C210 
S-c 
253 
10 min 
F101 
1,20 A 
Unit shut down after 3 sec. 
Input current stabilised at 0,11 A. 
T102 damaged. 
Dielectric strength test OK. 
No hazard. 
D204 
S-c 
253 
A - C 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
C207 
S-c 
253 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 39 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
FAULT CONDITION TESTS (Continued) 
P
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
D214 
S-c 
253 
A - C 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
C222 
S-c 
253 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
D217 
S-c 
253 
A - C 
10 min 
F101 
2,00 A 
Unit shut down after 2 sec. 
Input current stabilised at 0,10 A. 
D216 damaged. 
No hazard. 
C225 
S-c 
253 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
D217 damaged. 
No hazard. 
D218 
S-c 
253 
AC – (+) 
30 min 
F101 
0,96 A 
Normal operated. 
Input current stabilised at 0,96A. 
No component damaged. 
No hazard. 
C229 
S-c 
253 
1 hr 
F101 
0,97 A 
Normal operated. 
Input current stabilised at 0,97A. 
No component damaged. 
No hazard. 
Q203 
S-c 
253 
E - B 
30 min 
F101 
0,96 A 
Normal operated. 
Input current stabilised at 0,96A. 
No component damaged. 
No hazard. 
Q203 
S-c 
253 
E - C 
10 min 
F101 
1,12 A 
Output signal off after 3 sec. 
Input current stabilised at 0,37A. 
R223 opened. 
No hazard. 
PC102 
S-c 
253 
Pin 3 - 4 
(Pri. side)
 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
PC102 
S-c 
253 
Pin 1 - 2 
(Sec. side)
 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 40 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
FAULT CONDITION TESTS (Continued) 
P
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
PC101 
S-c 
253 
Pin 3 - 4 
(Pri. side)
 
30 min 
F101 
0,96 A 
Normal operated. 
Input current stabilised at 0,96A. 
No component damaged. 
No hazard. 
PC101 
S-c 
253 
Pin 1 - 2 
(Sec. side)
 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
AMP 
module 
installed 
FAN 
Locked 253 
45 
min  F101
 
0,96 A 
Protection circuit in AMP module 
operated after 42 min. 
Input current stabilised at 0,14 A. 
No component damaged. 
No hazard.
 
Front 
speaker 
terminal 
S-c 
253 
R - G 
10 min 
F101
 
0,14 A 
Unit shut down immediately. 
Input current stabilised at 0,14 A. 
No component damaged. 
No hazard.
 
Pmax. 
opening 
- 253 
- 3 
hr 
F101
 
3,86 A 
Components are heated-up to (
∆t);
- T101 coil 
: 80K 
- T101 core 
: 62K 
- T102 coil 
: 44K 
- T102 core 
: 40K 
- T103 coil  
: 71K 
- T201 coil 
: 48K 
- T201 core 
: 46K 
- T202 coil 
: 47K 
- T202 core 
: 45K 
- LF101 coil 
: 30K 
- LF102 coil 
: 31K 
and stabilised.  
Input current stabilised at 3,86 A. 
Dielectric strength test O.K. 
No hazard
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 