IEC 60065, 6th edition : 1998
 - 
- Page 17 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
a) Temperature rise of printed circuit 
boards (PCB) to 20.1.3, exceeding 
the limits of Table 2 by not more 
than 100 K for an area not greater 
than 2 cm²  
 
 
b) Temperature rise of printed circuit 
boards (PCB) to 20.1.3 up to 300 K 
for an area not greater than 2 cm² 
for a maximum of 5 min  
 
 
Meets all the special conditions if 
conductors on printed circuit boards 
are interrupted  
No conductors are interrupted/peeled/loosened during 
fault conditions 
11.2.4 
Temperature rise of parts acting as 
a support or mechanical barrier  
Temperature rises are within the limits. 
11.2.5 
Temperature rise of windings  
See Fault Condition tests 
11.2.6 
Temperature rise of parts not 
subject to the limits of 11.2.1 to 
11.2.5, table 2 item e).  
No excessive temperature observed/measured on other 
parts. 
 
12 
MECHANICAL STRENGTH  
 
12.1.1 
Bump test (>7kg) 
No damage in the sense of this standard 
12.1.2 
Vibration test (portable, musical 
amplifiers, metal enclosure) 
Assessed to be satisfactory constructed. 
12.1.3 
Impact test (0.5J) 
No damage in the sense of this standard 
12.2 
Fixing of knobs, push buttons, keys 
and levers  
Normal use will not impair the protection against electric 
shock. 
12.3 
Remote controls with hazardous live 
parts  
No remote control containing hazardous live parts 
12.4 
Drawers (pull test 50 N, 10 s)  
No drawers 
12.5 
Antenna coaxial sockets providing 
isolation  
No antenna socket which insolate hazardous live parts 
from accessible parts. 
 
13 
CLEARANCES AND CREEPAGE 
DISTANCES 
 
13.1.1 
Clearances and creepage distances 
in accordance with 13.2 (fig. 9); 
minimum distance    
See 13.2 
 
Reduction applied if the 3 conditions 
are met    
No reduction applied 
 
Reduction applied for Grade 2 
winding wire    
No 
13.1.2 
Use of cemented joints    
No cemented joints 
 
Tests to confirm cemented joints  
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 18 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
13.2 
Class I apparatus 
Class II apparatus 
 
Creepage distances and 
clearances between live parts and 
safety earthed parts (basic 
insulation) 
 
 
Creepage distances and 
clearances between live parts and 
not safety earthed accessible parts 
(reinforced or double insulation) 
 
 
Class II apparatus 
 
 
Creepage distances and 
clearances between live parts and 
not accessible parts (basic 
insulation) 
Measured minimum distances: 
6,4 mm (reactor, PT01 insulation between W1 and W2). 
 
Creepage distances and 
clearances between not accessible 
parts and accessible parts 
(supplementary insulation) 
 
 
Creepage distances and 
clearances between live parts and 
accessible parts (reinforced or 
double insulation)  
Measured minimum distances: 
- 6,0 mm (pr - sec) 
- 6,5 mm (pr - accessible parts) 
 
Creepage distances and 
clearances measured whilst forces 
of 2N and 30N are applied  
No reduction of clearance/creepage distances when 2N 
is applied on internal parts and 30N at the enclosure. 
 
 
Clearances and creepage 
distances of parts of different 
polarity directly connected to the 
mains, as in fig. 9; minimum 
distance    
Measured minimum distances: 3,0 mm 
 
Clearances and creepage 
distances between conductors on 
printed circuit boards, one of which 
may be conductively connected to 
the mains, as in fig. 10 (overheating 
only) 
No overheating of conductors on PWB. 
13.3 
Enclosed, enveloped or hermetically 
sealed parts: clearances and 
creepage distances to Table 4  
No such parts in the apparatus 
13.4 
Parts filled with insulating 
compound, meeting the 
requirements of 8.8  
No components or subassemblies filled with compound. 
13.5 
Type B coated printed circuit boards 
complying with IEC 60 664-3 (basic 
insulation only)  
No type B coated PWB 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 19 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
14 COMPONENTS 
 
 
14.1 Resistors 
 
 
 
a) Resistors between hazardous 
live parts and accessible metal 
parts, or bridging contact gaps on 
mains switch.  
 
 
b) Resistors, other than between 
hazardous live parts and accessible 
parts  
 
14.2 
Capacitors and RC units 
 
 
 
Capacitors separately approved  
Yes 
14.2.1 
Y capacitors tested to IEC 384-14, 
2nd edition    
C104, C105, C119, C127, C128 are Y capacitors, 
Certified according to IEC 384-14, 2nd edition. 
14.2.2 
X capacitors tested to IEC 384-14, 
2nd edition    
C101, C102, C103, C403 are X capacitors, 
Certified according to IEC 384-14, 2nd edition. 
Part No 
Manufacturer 
Value 
Type 
Marking 
Approved by 
C101, C103 
Pilkor Electronics 
1,0 uF 275V 
PCX2 335M 
1uM, X2 
VDE 
C102 
Pilkor Electronics 
0,47 uF 275V
PCX2 335M 
470nM, X2 
VDE 
C104, C105, C119 
Netron Tech. 
1000pF 250V
AD 
102M, X1/Y1 
VDE 
C127, C128 
Netron Tech. 
470pF 250V 
AD 
471M, X1/Y1 
VDE 
C403 
Netron Tech. 
4700pF 250V
AA 
472M, X1/Y2 
VDE 
 
 
 
 
 
 
 
 
 
 
 
 
14.2.3 
Capacitors operating at mains 
frequency but not connected to the 
mains: tests for X2    
No such capacitor 
14.2.5 
Capacitors with volume exceeding 
1750 mm³, where short-circuit 
current exceeds 0,2 A: compliance 
with IEC 60 384-1, 4.38 category B 
or better   
Cap, volume exceeding 1750 mm
³;
 
a) X-cap.: C101, C102, C103 
b) Several E. cap. 
c) Polyester film cap.: C121,  
 
Accepted due to below, 
a) Certified according to IEC384-14, 2nd ed. 
b) Metal cases. 
c) Complies with IEC60384-1, 4.38, to category B. 
 
Capacitors with volume exceeding 
1750 mm³, mounted closer to a 
potential ignition source than 
Table 5 permits: compliance with 
IEC 60 384-1, 4.38 category B or 
better    
Cap, volume exceeding 1750 mm
³;
 
a) X-cap.: C101, C102, C103 
b) Several E. cap. 
c) Polyester film cap.: C121,  
 
Accepted due to below, 
a) Certified according to IEC384-14, 2nd ed. 
b) Metal cases. 
c) Complies with IEC60384-1, 4.38, to category B. 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 20 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
Shielded by a barrier to FV 0 or 
metal    
No barrier required. See above. 
14.3 
Inductors and windings 
 
 
14.3.1 
Transformers and inductors marked 
with manufacturer's name and type   
Adequate marking applied 
14.3.2 Transformer 
category 
Isolating transformer 
14.3.3-5 Transformer 
construction 
See below. 
14.3.3.2 
Transformers meet the 
constructional requirements : 
See below. 
Transformer/motor Insulation 
Insulation Test 
Flashover Creepage 
distances 
Part No/markings 
Between 
Resistance 
Voltage 
Breakdown 
and clearances 
 
 
  M Ohm 
KV(60)s 
voltage kV 
Measured 
Required  
T101
 / TPW-4102 
Pr- sec 
> 100 
3KV (rms) 
7,9 mm 
 6 mm  
 
Pr- ic 
> 100 
3KV (rms) 
 
6,5 mm 
 6 mm  
 
 
 
 
 
 
 
T102 
 / KJP-10013T2 **) 
Pr- sec 
> 100 
3KV (rms) 
6,0 mm 
 6 mm  
 
 
 
 
 
 
 
T103
  / KJP-7013T1 **) 
Pr - sec 
> 100 
3KV (rms) 
6,0 mm 
 6 mm 
 
 
 
 
 
 
 
T201, T202 
/ KJP-10013T3 *) 
Pr - sec 
> 100 
3KV (rms) 
6,0 mm 
 6 mm 
 
 
 
 
 
 
 
PT01
 / RE-2500 ***) 
Pr- pr 
> 100 
1.5KV (rms) 
- 6,4 
mm 
 6 mm  
 
Pr- ic 
> 100 
3KV (rms) 
 
6,5 mm 
 6 mm  
 
 
 
 
 
 
 
*) Barrier tape provided:    Bottom side - 6,0 mm  /  Top side - 3,0 mm.  
**) Top side 
: Min. 3,0 mm spacing or min. 3,0 mm barrier tape provided. 
Bottom side  : Min. 6,0 mm spacing or 6,0 mm barrier tape provided. 
***) Reactor, before mains fuse. 
 
Components / construction  
(Transformer: T101)
 
Windings on single bobbin. The center flange provided 
between primary and secondary winding.  
Bobbin thickness:> 0,4mm  
 
Components / construction  
(Transformer: T102, T103, T201, T202)
 
Concentric windings on one bobbin. At least 3 layers of 
insulation between primary and secondary winding. 
Thickness of each layer: 0.025 mm. Voltage test : 3kV.
 
Components / construction  
(Reactor: PT01)
 
Windings on single bobbin. The center flange provided 
between primary W1 and primary W2 windings.  
Bobbin thickness:> 0,4mm  
Page of 53
Display