Harman Kardon DPR 1005 (serv.man13) EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 13 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
8.7 
Basic insulation between parts at 
35 V to 71 V (peak) a.c. or 60 V to 
120 V d.c. and accessible parts  
No parts at 35-71V a.c. or 60-120V d.c. 
 
Reinforced or double insulation 
between circuits operating at 
voltages between 35 V and 71 V 
(peak) a.c. or between 60 V and 
120 V d.c. and hazardous live parts 
at higher voltage  
No parts at 35-71V a.c. or 60-120V d.c. 
 
Separation by Class II isolating 
transformer  
Isolating transformer according to 14.3.2. (Class II) 
 
Separation by Class I transformer  
 
 
Separation by earthed conductive 
part  
 
8.8 
Basic or supplementary insulation 
≥ 0,4 mm (mm)    
Insulation in reactor PT01 (before mains fuse),  
partition walls 
≥ 0,4 mm between W1 and W2 windings, 
meet 10.3. 
 
Reinforced insulation 
≥ 0,4 mm 
(mm)    
Insulation in transformers and reactor, ref. 14.3. 
 
Thin sheet insulation used inside  
the enclosure
 
 
 
Basic or supplementary insulation, 
at least two layers, each meeting 
10.3  
 
 
Basic or supplementary insulation, 
three layers any two of which meet 
10.3  
 
 
Reinforced insulation, two layers 
each of which meet 10.3  
 
 
Reinforced insulation, three layers 
any two which meet 10.3  
T102, T103, T201, T202 Transformers with thin sheet 
insulation, ref. 14.3. 
8.9 
Primary wiring : 
Adequate insulation between 
internal hazardous live conductors 
and accessible parts  
Double insulated 
 
Secondary wiring : 
Adequate insulation between 
internal hazardous live parts and 
conductors connected to accessible 
parts  
Single insulated but safely anchored 
8.10 
Class II apparatus : 
Double insulation between 
conductors connected to the mains 
and accessible parts  
Double insulated, tested according to 8.9. and 10.3. 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 14 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
Class II apparatus : 
Double insulation between 
conductors connected to accessible 
parts and the mains  
 
8.11 
Detaching of wires 
 
 
 
No undue reduction of creepage or 
clearance distances if wires become 
detached  
Primary wires connected with multi-contact-housing. 
 
Vibration test carried out    
Vibration test considered not necessary  
8.12 
Adequate cross-sectional area of 
internal wiring to mains socket-
outlets  
No internal wiring for mains socket outlets, 
but socket outlet fuses provided: F401, T2A/250V. 
8.13 
Adequate fastening of windows, 
lenses, lamp covers etc. (push or 
pull test 20 N for 10 s)  
Adequately fastened. 
8.14 
Adequate fastening of covers (push 
or pull test 50 N, for 10 s)  
Covers adequately fastened with screws. 
 
8.15 
No risk of damage to the insulation 
of internal wiring due to hot parts or 
sharp edges  
Wires safely anchored away from parts with high 
temperature. 
8.16 
Apparatus designed to be supplied 
by special supply apparatus only.  
 
 
ELECTRIC SHOCK HAZARD 
UNDER NORMAL OPERATING 
CONDITIONS  
 
9.1.1 
Touch current expressed as 
voltages U1 and U2 in Annex D  
 
Location Measured 
U1 
V (peak) 
Measured U1
V (DC) 
Measured U2 
V (peak) 
Limits : 
U1 Max 35V (peak)
U1 Max 1.0V (DC) 
U2 Max 0.35V 
(peak) 
Mains pole 1 – Video Out Terminal 
0,66 V (peak) 
0,33 V (peak) 
Pass 
Mains pole 2 – Video Out Terminal 
1,10 V (peak) 
0,31 V (peak) 
Pass 
 
 
 
 
 
 
 
 
 
 
 
Discharge not exceeding 45 
µC  
No part or contact of a terminal with stored voltages 
between 60V - 15kV 
 
Energy of discharge not exceeding 
350 mJ  
No part or contact of a terminal with stored voltages 
exceeding 15kV 
 
Test with test finger according to test 
probe B of IEC 61 032 (20N) 
No access to hazardous live parts 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 15 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
For class II constructions, test with 
test probe 13 of IEC 61 032 (3N) 
No access to hazardous live parts 
 
 
Clearances to circuits exceeding 
1000V a.c. or 1500V d.c.  
No voltages exceeding 1000V AC or 1500V DC. 
9.1.2 
No hazardous live shafts of knobs, 
handlers or levers  
No live shafts, handles or levers 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin  
No access for the test pin. 
 
9.1.4 
Terminal devices tested with 
1 mm x 20 mm test pin (10 N); test 
probe 16 of IEC 61 032  
Does not reach hazardous live parts 
 
Terminal devices tested with 
1 mm x 100 mm straight wire (1 N); 
test probe D of IEC 61 032  
Does not reach hazardous live parts 
9.1.5 
Pre-set controls tested with 
2.5 mm x 100 mm test pin (10 N); 
test probe C of IEC 61 032  
No preset controls 
9.1.6 
No shock hazard due to stored 
charge on withdrawal of the mains 
plug; voltage (V) after 2 s    
0V after 2 sec. 
Discharge resistor provided, R102, 1M
Ω, 1/2W. 
 
If C is not greater than 0,1 
µF no test 
needed  
 
9.1.7 
Enclosure sufficiently resistant to  
external force 
 
 
 
Test probe 11 of IEC 61 032 for 10 s 
(50 N)  
Test with test finger results in no hazard. 
 
Test hook of fig. 4 for 10 s (20 N)  
Test with test hook results in no hazard. 
 
Conductive enclosures : 
30 mm diameter test tool for 5 s 
(100 or 250 N)    
Test with 100N results in no damage. 
9.2 
No hazard 2s after removing a cover 
by hand  
No cover removable by hand 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 16 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
10 
INSULATION REQUIREMENTS  
 
10.1 
Insulation resistance (M
Ω) at least 
2 M
Ω min. after surge test for basic 
and 4 M
Ω min. for reinforced 
insulation    
> 4 M
Ω 
10.2 
Humidity treatment 48 h or 120 h    
120 h  (40
°C). No impairment 
10.3 
Insulation resistance and dielectric 
strength   
 
Tested insulation 
Insulation  
Test voltage 
Voltage test 
Remarks 
 
Resistance 
based on the 
(r.m.s.value) 
 
 
     (M Ohm) 
Operating 
 
 
 Meas- 
Min. 
Voltage 
 
 
 Ured 
required 
(V) 
(V) 
 
Between the poles 
 
 
For rated mains 
 
 
of the circuit    
:
 
> 2 
 2 
voltages 
≤ 150V
 
 
directly connected 
 
 
r.m.s, 1410V pk 
 
 
to the supply 
 
 
 
 
 
mains 
 
 
For rated mains 
 
 
 
 
 
voltages 
≥ 150V
1500 V 
Pass 
 
 
 
r.m.s, 2120V pk 
 
 
Basic insulation 
:
 
> 100 
 2 
Curve A,
 
 
1500 V 
Pass – (reactor insulation) 
  
 
Fig. 
 
 
Supplementary  
  
 
 
insulation   
 
:
 
 
 2 
Curve A,
 
 
 
  
  
 
Fig. 
 
 
Reinforced  
 
 
 
 
insulation        
:
 
> 4 
 4 
Curve B,
 
 
3000 V 
Pass 
  
 
Fig. 
 
 
 
11 
FAULT CONDITIONS  
 
11.1 
No electric shock hazard under fault 
conditions  
No electric shock hazard under fault conditions 
11.2 
Heating under fault condition 
 
 
 
No hazard from softening solder  
Neither danger of fire to surroundings nor abnormal heat 
developed 
 
No flaming more than 10s  
No flaming 
11.2.1 
Measurement of temperature rises  
See appended table, fault condition tests 
11.2.2 
Temperature rise of accessible parts 
See appended table, fault condition tests 
11.2.3 
Temperature rise of parts, other than 
windings, providing electrical 
insulation  
See appended table, fault condition tests 
 
Temperature rise of printed circuit 
boards (PCB) exceeding the limits of 
Table 2 by max. 100 K for max. 
5 min  
No area where temperature exceeds 100K above limits 
 
Page of 53