Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-360.pdf
Date

Harman Kardon AVR 360 EMC - CB Certificate ▷ View online

 
 
- Page 29 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
 
IEC 62151 clause 4.1.1:  
Add after the first paragraph: 
NOTE- In Finland, Norway and Sweden, class I 
equipment  
which is intended for connection to the building  
installation via a non-industrial plug or a non-
industrial  
appliance coupler or both and in addition is intended 
for connection to other equipment or a network shall,
if safety relies on connection to protective earth or if 
surge suppressors are connected between the  
network terminals and ACCESSIBLE parts, have  
a marking stating that the equipment must be  
connected to an earthed mains socket-outlet. 
The marking text in the applicable countries shall 
be as follow: 
 
In Finland;  
”Laite on liitettävä suojamaadoituskoskettimilla 
va rustettuumpistorasiaan” 
 
In Norway; ”Apparatet mǻ tikoples jordet stikkontakt”
 
In Sweden; ”Apparaten skall anslutas till jordat 
uttag” 
Class II apparatus. 
N/A 
 
 
- Page 30 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
 
L. 5 
Marking and instructions 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used ………: 
No electronic flash apparatus 
N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used …………: 
 N/A 
L. 7 
Heating under normal operating conditions 
N/A 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in Table  
3 , unless comply with 6.2.2.1.or 6.2.2.2 of IEC 
60086-4 ………………………....: 
No lithium batteries 
N/A 
L. 9 
Electric shock hazard under normal operating conditions 
N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE ………………………: 
Not flash synchroniser. 
N/A 
L.10 Insulation 
requirements 
N/A 
L. 10.3.2 
High frequency puls ignition ………..: 
 
N/A 
L. 12 
Mechanical strength 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel ball 
impact test ……………………………...: 
 
N/A 
L. 14 
Components 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions ………….: 
 
N/A 
L. 20 
Resistance to fire 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE …..: 
 
N/A 
 
 
 
- Page 31 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
TRF No. IEC60065_I 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by position of 
the functional switch (W)  
Less than 0.92W  
(at 240V)  
— 
Operating conditions 
Standby mode at 50Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
230 0.0051 0.85 
— 
240 0.0056 0.92 
— 
Standby mode at 60Hz;
 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
230 0.0041 0.80 
— 
240 0.0042 0.85 
— 
 
 
 
 
Measured at maximum non-clipped output at 50Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
264 4.96 1084 
F) 
2 x 78.0 
SB)  2 x 79.9 
C) 
1 x 76.2 
S) 
2 x 78.8 
Measured at maximum non-clipped output at 60Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
264 4.86 1071 
F) 
2 x 78.0 
SB)  2 x 79.9 
C) 
1 x 76.2 
S) 
2 x 78.8 
 
 
 
 
Tested condition; 1kHz input signal, connected 8 ohm loads for F, SB, C, S channels 
 
 
- Page 32 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
TRF No. IEC60065_I 
Measured at 1/8 of maximum non-clipped output at 50Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
207 2.15 
#) 2.00 
342.2 
#) 313.7 
 
 
 
F) 
2 x 9.75 
SB)  2 x 9.99 
C) 
1 x 9.53 
S) 
2 x 9.85 
 
 
230 2.20 
#) 2.05 
395.6 
#) 355.2 
240 2.23 
#) 2.07 
406.0 
#) 374.5 
264 2.28 
#) 2.12 
454.3 
#) 419.4 
Measured at 1/8 of maximum non-clipped output at 60Hz: 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
207 2.11 
#) 1.97 
337.7 
#) 312.3 
 
 
 
F) 
2 x 9.75 
SB)  2 x 9.99 
C) 
1 x 9.53 
S) 
2 x 9.85 
 
 
230 2.16 
#) 2.03 
382.5 
#) 353.5 
240 2.18 
#) 2.06 
400.0 
#) 370.1 
264 2.23 
#) 2.11 
447.5 
#) 418.1 
 
 
 
 
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm loads for all channels connected 
condition, and then replaced the input signal to pink noise for normal heating and fault condition tests for fan 
stalled and blocked opening (Other tests in the fault condition tests were performed with 1 kHz sign wave 
input signal for monitoring the signal outputs). 
The values followed #) in table above are measured “A” or “W” values, when replaced the input signal from 
1 kHz sign wave to pink noise. 
 
 
Loudspeaker impedance (Ω)  .........
8 Ohms 
— 
 
Several loudspeaker systems 
Right and Left for Front, 
Right and Left for Surround Back / Zone 2, 
Right and Left for Surround, 
Only one for Center. 
 
Marking of loudspeaker terminals
SPEAKERS (8Ω):  
FRONT RIGHT, FRONT LEFT,  
SBR/ ZONE 2 R, SBL/ZONE 2 L,  
SURR. RIGHT, SURR. LEFT, CENTER. 
 
Page of 65
Display

Click on the first or last page to see other AVR 360 service manuals if exist.