Harman Kardon AVR 360 EMC - CB Certificate ▷ View online
- Page 29 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
IEC 62151 clause 4.1.1:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment
which is intended for connection to the building
installation via a non-industrial plug or a non-
industrial
appliance coupler or both and in addition is intended
for connection to other equipment or a network shall,
if safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts, have
a marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follow:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment
which is intended for connection to the building
installation via a non-industrial plug or a non-
industrial
appliance coupler or both and in addition is intended
for connection to other equipment or a network shall,
if safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts, have
a marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follow:
In Finland;
”Laite on liitettävä suojamaadoituskoskettimilla
va rustettuumpistorasiaan”
”Laite on liitettävä suojamaadoituskoskettimilla
va rustettuumpistorasiaan”
In Norway; ”Apparatet mǻ tikoples jordet stikkontakt”
In Sweden; ”Apparaten skall anslutas till jordat
uttag”
uttag”
Class II apparatus.
N/A
- Page 30 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used ………:
apparatus indicating type or model number of flash
apparatus with which it is to be used ………:
No electronic flash apparatus
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used …………:
model number of battery chargers or Supply
apparatus with which it is to be used …………:
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.6
L11.2.6
Lithium batteries meet permissible temp rise in Table
3 , unless comply with 6.2.2.1.or 6.2.2.2 of IEC
60086-4 ………………………....:
3 , unless comply with 6.2.2.1.or 6.2.2.2 of IEC
60086-4 ………………………....:
No lithium batteries
N/A
L. 9
Electric shock hazard under normal operating conditions
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE ………………………:
HAZARDOUS LIVE ………………………:
Not flash synchroniser.
N/A
L.10 Insulation
requirements
N/A
L. 10.3.2
High frequency puls ignition ………..:
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test ……………………………...:
impact test ……………………………...:
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions ………….:
function under normal conditions ………….:
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE …..:
to be a POTENTIAL IGNITION SOURCE …..:
N/A
- Page 31 of 44 -
Report
No.
129950
TRF No. IEC60065_I
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by position of
the functional switch (W)
the functional switch (W)
Less than 0.92W
(at 240V)
(at 240V)
—
Operating conditions
Standby mode at 50Hz;
Standby mode at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
230 0.0051 0.85
—
240 0.0056 0.92
—
Standby mode at 60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
230 0.0041 0.80
—
240 0.0042 0.85
—
Measured at maximum non-clipped output at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
264 4.96 1084
F)
2 x 78.0
SB) 2 x 79.9
C)
C)
1 x 76.2
S)
2 x 78.8
Measured at maximum non-clipped output at 60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
264 4.86 1071
F)
2 x 78.0
SB) 2 x 79.9
C)
C)
1 x 76.2
S)
2 x 78.8
Tested condition; 1kHz input signal, connected 8 ohm loads for F, SB, C, S channels
- Page 32 of 44 -
Report
No.
129950
TRF No. IEC60065_I
Measured at 1/8 of maximum non-clipped output at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
207 2.15
#) 2.00
342.2
#) 313.7
F)
2 x 9.75
SB) 2 x 9.99
C)
C)
1 x 9.53
S)
2 x 9.85
230 2.20
#) 2.05
395.6
#) 355.2
240 2.23
#) 2.07
406.0
#) 374.5
264 2.28
#) 2.12
454.3
#) 419.4
Measured at 1/8 of maximum non-clipped output at 60Hz:
Un (V)
In (A)
Pn (W)
Pout (W)
207 2.11
#) 1.97
337.7
#) 312.3
F)
2 x 9.75
SB) 2 x 9.99
C)
C)
1 x 9.53
S)
2 x 9.85
230 2.16
#) 2.03
382.5
#) 353.5
240 2.18
#) 2.06
400.0
#) 370.1
264 2.23
#) 2.11
447.5
#) 418.1
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm loads for all channels connected
condition, and then replaced the input signal to pink noise for normal heating and fault condition tests for fan
stalled and blocked opening (Other tests in the fault condition tests were performed with 1 kHz sign wave
input signal for monitoring the signal outputs).
condition, and then replaced the input signal to pink noise for normal heating and fault condition tests for fan
stalled and blocked opening (Other tests in the fault condition tests were performed with 1 kHz sign wave
input signal for monitoring the signal outputs).
The values followed #) in table above are measured “A” or “W” values, when replaced the input signal from
1 kHz sign wave to pink noise.
1 kHz sign wave to pink noise.
Loudspeaker impedance (Ω) .........
8 Ohms
—
Several loudspeaker systems
Right and Left for Front,
Right and Left for Surround Back / Zone 2,
Right and Left for Surround,
Only one for Center.
Right and Left for Surround Back / Zone 2,
Right and Left for Surround,
Only one for Center.
P
Marking of loudspeaker terminals
SPEAKERS (8Ω):
FRONT RIGHT, FRONT LEFT,
SBR/ ZONE 2 R, SBL/ZONE 2 L,
SURR. RIGHT, SURR. LEFT, CENTER.
FRONT RIGHT, FRONT LEFT,
SBR/ ZONE 2 R, SBL/ZONE 2 L,
SURR. RIGHT, SURR. LEFT, CENTER.
P
Click on the first or last page to see other AVR 360 service manuals if exist.