- Page 9 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
Constructional requirements with regard to the protection against electric shock 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare …………: 
Considered 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
………….: 
Operation “By hand” not 
possible 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material ………..: 
No hygroscopic materials 
used 
N/A 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand: 
No cover removable by hand 
N/A 
8.5 
Class I equipment …………………...: 
Class II equipment 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts ……………………………: 
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a) ……………..: 
No such resistors 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a) ……………………….......:  
No such capacitors 
N/A 
 
Protective earthing terminal …………...: 
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment …………………...: 
Class II equipment 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts ………..: 
Double/Reinforced insulation 
complies with requirements 
specified in clause 10 and 13. 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3 ……..: 
The apparatus has isolating 
transformers complies with  
clause 14.3 
 
Basic insulation bridged by components complying 
with 14.3.4.3. ………………………...: 
No such components 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) …: 
No such capacitors. 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a) …….: 
No such capacitors. 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b) ………: 
No such capacitors 
N/A 
 
 
- Page 10 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
8.7 
This clause is void ………………………..: 
 
— 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
 
N/A 
 
Reinforced insulation > 0,4 mm (mm) ……: 
Bobbin in main and sub  
transformer. (ref. 14.3) 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22) ………:   
No thin sheet insulation. 
N/A 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 ….....: 
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 ………………......: 
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3 ……...: 
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 ……………………….: 
 N/A 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts .: 
Double insulated 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts:
Single insulation, but safely 
anchored. 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. …………………...: 
Double insulated according to 
8.9. and 10.3 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts: 
Single insulation, but safely 
anchored. 
N/A 
8.11 
Detaching of wires …………………………………..: 
 
 
No undue reduction of creepages or clearance 
distances if wires become detached ……………: 
Primary wires are connected 
with multi-contact-housing 
 
Vibration test carried out …………: 
See 12.12 
N/A 
8.12 
This clause is void ………………..: 
 
— 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s) …………………...: 
Adequately fastened. 
8.14 
Adequate fastening of covers (push/pull test 50 N  
for 10 s) ……………………..: 
Covers adequately 
fastened with screws. 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges …………: 
Wires safely anchored away 
from parts with high 
temperature. 
8.16 
Only special supply equipment can be used : 
Not supplied by a special 
supply apparatus. 
N/A 
 
 
- Page 11 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
8.17 
Insulated winding wire without additional interleaved 
insulation ……………………………………………..: 
No such winding wire. 
N/A 
8.18 
Endurance test as required by 8.17 ……………….: 
 
N/A 
8.19 
Disconnection from the mains 
See below 
N/A 
8.19.1 
Disconnect device ………………………………......: 
Mains plug is used as 
disconnect devices 
 
All-pole switch or circuit breaker with >3mm contact 
separation ……………………: 
No all-pole switch or circuit  
breaker. 
N/A 
8.19.2 Mains 
switch 
ON indication …………………...: 
Indicator lamp or FL display 
lit-on for mains switch ON  
indication, but switch is single 
pole only. 
8.20 
Switch not fitted in the mains cord …………: 
No such application of the 
mains switch 
8.21 
Bridging components comply with clause 14 ….: 
C904capacitor, bridging  
contact gaps of the mains relay.
Certified component. 
See appended table, list of 
critical components. 
8.22 Non-separable 
thin 
sheet material …………...: 
 
N/A 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation ……….: 
No voltage exceeding 
1000V ac or 1500V dc.  
N/A 
9.1.1.1 
a) Open circuit voltages …………………….: 
Mains input voltage 
> 35 Vac, see below. 
 
 
b) Touch current measured from terminal devices 
using the network in annex D ………………………: 
(see appended table 9.1.1.1) 
 
c) Discharge not exceeding 45 μC ……...: 
No part or contact of a 
terminal with stored voltages  
between 60V - 15 kV. 
N/A 
 
d) Energy of discharge not exceeding 350 mJ: 
No part or contact of a terminal 
with stored voltages exceeding 
15kV. 
N/A 
9.1.1.2 
Test with test finger and test probe …...: 
No access to hazardous  
live parts 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers: 
No live shaft, handles or levers 
N/A 
 
 
- Page 12 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin ……: 
No access for the test pin  
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032 …………………: 
Does not reach hazardous live 
parts 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 ……: 
Does not reach hazardous live 
parts 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
……………….: 
No preset controls 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 
2 s …: 
See below 
N/A 
 
If C is not greater than 0,1 μF no test needed ……: 
<
 0,1 μF 
9.1.7 
Resistance to external forces
 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N) …...: 
Test with test finger  
result in no hazard 
 
b) Test hook of fig. 4 for 10 s (20 N) ……: 
Test with test hook results in  
no hazard. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N) : 
Tested with 100N results in  
no damage. 
9.2 
No hazard after removing a cover by hand ……….: 
No cover removable by hand 
N/A 
 
10 Insulation 
requirements 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ……………………………………………..: 
> 100 M
Ω after surge test 
10.2 
Humidity treatment 48 h or 120 h ………………….: 
Performed for 120 h at temp.  
40
°C and humidity 93% 
10.3 
Insulation resistance and dielectric strength between 
mains terminals ……………………………………...: 
(see appended table 10.3) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1) : 
Class II apparatus 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II) ……………..: 
(see appended table 10.3) 
 