Harman Kardon AVR 360 EMC - CB Certificate ▷ View online
- Page 17 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met ……………………………….:
protective screening only if all 7 conditions of
14.3.4.2 are met ……………………………….:
Class II apparatus.
No such transformer used.
No such transformer used.
N/A
14.3.4.3
Separating transformers with at least basic
insulation:
insulation:
Windings of Class II
construction used.
construction used.
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation) ……………...:
between hazardous live parts and accessible parts
(double or reinforced insulation) ……………...:
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm …...:
Main and Sub transf. bobbin
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal ………………:
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal ………………:
Winding of Class II
construction used.
construction used.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity ……..:
adequate current-carrying capacity ……..:
N/A
14.4
High voltage components ……………………..:
No high-voltage components.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved .....................:
(peak) separately approved .....................:
N/A
Component meets category V-1 of IEC 60707:
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission ……………………:
part of the submission ……………………:
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission ………………………:
part of the submission ………………………:
N/A
14.5 Protective
devices
P
Protective devices used within their ratings ………:
Thermal link and fuses
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened ………………………......:
requirement of clause 13 for the voltage across the
device when opened ………………………......:
Certified protective devices
applied. See appended table,
list of critical components.
applied. See appended table,
list of critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved …………:
N/A
b) Thermal cut-outs tested as part of the submission:
N/A
- Page 18 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.5.1.2
a) Thermal links separately approved …………..:
Thermal link in main transf.,
separately approved compo.
See appended table,
list of critical components
separately approved compo.
See appended table,
list of critical components
P
b) Thermal links tested as part of the submission ….:
N/A
14.5.1.3
Thermal devices re-settable by soldering …………:
No thermal device
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
……………………………………………….......:
60127
……………………………………………….......:
Fuses are approved
components according to
IEC 60127.
See appended table, list of
critical components.
components according to
IEC 60127.
See appended table, list of
critical components.
P
14.5.2.2
Correct marking of fuse-links adjacent to
holder ……:
holder ……:
The following marking applied;
Mains fuses;
F901: T6.3A L 250V
F902: T2.5A L 250V
F901: T6.3A L 250V
F902: T2.5A L 250V
Secondary fuse;
F110: T5A L 250V
F111: T5A L 250V
F110: T5A L 250V
F111: T5A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ………….:
No fuse holder so designed
that fuse-links can be
connected in parallel
that fuse-links can be
connected in parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ……..:
replacing fuse-links without the use of a tool ……..:
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
……….:
……….:
No PTC’s thermistors.
N/A
PTC-S devices (15 W) category V-1 or better
………:
………:
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked …………......:
No such components
N/A
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1 ……………...:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1 ……………...:
Mains switch and relay are
certified components
according to IEC 61058-1.
See appended table,
list of critical components.
certified components
according to IEC 61058-1.
See appended table,
list of critical components.
P
- Page 19 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.6.1 b)
Tested in the apparatus …………………….:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1 ………………………….:
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1 ………………………….:
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1 …………………………………:
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1 …………………………………:
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 ……………………………………:
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 ……………………………………:
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation ………………...:
1 subclause 13.1 and has making/breaking action
independent of speed of actuation ………………...:
Separately approved switch
and relay.
and relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use ……………………:
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use ……………………:
Separately approved switch
and relay.
and relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength ………………………………………...….:
strength ………………………………………...….:
Separately approved switch
and relay.
and relay.
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1 …………………….:
additional tests to IEC 60058-1 …………………….:
Measured inrush current
through mains switch is
through mains switch is
< 1 A.
The measured inrush current
is less than rated current of
the mains switch (6A) - O.K..
is less than rated current of
the mains switch (6A) - O.K..
Measured inrush current
through mains relay;
27A + 20 A * = 47 A
*) Added current for socket
outlet (
through mains relay;
27A + 20 A * = 47 A
*) Added current for socket
outlet (
Socket outlet current
marking
: 0.5 A).
The measured inrush current
value is less than rated inrush
current rating of the mains
relay (100A). - O.K.
value is less than rated inrush
current rating of the mains
relay (100A). - O.K.
(The mains socket outlet is
controlled by the mains relay).
controlled by the mains relay).
P
Socket outlet current marking correct …………..:
Socket outlet marking:
SWITCHED (50W, 0.5A MAX)
SWITCHED (50W, 0.5A MAX)
P
14.7
Safety interlocks
N/A
Safety interlocks to 2.8 of IEC 60950 …………......:
No safety interlock
N/A
14.8
Voltage setting devices and the like ……………….:
No voltage setting devices.
N/A
- Page 20 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
Voltage setting device not likely to be changed
accidentally ………………………………………......:
accidentally ………………………………………......:
N/A
14.9 Motors
Low voltage DC fan motors.
P
14.9.1
Endurance test on motors …………………………….:
N/A
Motor start test …………………………………………:
N/A
Dielectric strength test ………………………………:
N/A
14.9.2
Not adversely affected by oil or grease etc. ………..:
The fans are not adversely
affected by oil, grease or other
substances.
affected by oil, grease or other
substances.
P
14.9.3
Protection against moving parts ……...:
The fans are placed inside the
unit. No access.
unit. No access.
P
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B ……………………….:
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B ……………………….:
No such construction.
The fans are low voltage DC
components only.
The fans are low voltage DC
components only.
N/A
14.10 Batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases …………………………………:
flammable gases …………………………………:
No batteries.
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries:
batteries:
N/A
14.10.3
Recharging currents and times within manufacturers
limits …………………………………………………….:
limits …………………………………………………….:
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits ……………………….:
within the manufacturers limits ……………………….:
N/A
14.10.4
Battery mould stress relief ………………………….:
N/A
14.10.5
Battery drop test ………………………………..:
N/A
14.11 Optocouplers
No optocouplers
N/A
Optocouplers comply with Cl. 8 ………………………:
N/A
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation) …………:
alternatively 13.6 (jointed insulation) …………:
N/A
14.12
Surge suppression varistors
No surge suppression varistors
N/A
Comply with IEC 61051-2 ……………………..:
N/A
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus ……………………………………….:
except for earthed parts of permanently connected
apparatus ……………………………………….:
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12 …………..:
thermal stress requirements of 14.12 …………..:
N/A