Harman Kardon AVR 360 EMC - CB Certificate ▷ View online
- Page 13 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
11 Fault
conditions
11.1
No shock hazard under fault condition ……………:
No electric shock hazard under
fault conditions.
fault conditions.
P
11.2
Heating under fault condition ………………….:
(see appended table 11.2)
P
Flames extinguish within 10 seconds ..................:
No flames
P
No hazard from softening solder ……………...:
No softening of solder
P
Soldered terminations not used as protective
mechanism ………………………………..:
mechanism ………………………………..:
No soldered terminations
P
11.2.1
Measurement of temperature rises ……..:
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts ……...:
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation ………:
providing electrical insulation ………:
(see appended table 11.2)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min ...:
exceeding the limits of table 3 by max. 100 K for
max. 5 min ...:
No exceeding the limits of
Table 3.
Table 3.
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm² :
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm² :
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min …………….:
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min …………….:
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted …...:
printed circuit boards are interrupted …...:
No conductors are
interrupted/peeled/loosened
during fault conditions
interrupted/peeled/loosened
during fault conditions
P
Class I protective earthing maintained ………….:
Class II equipment
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier ….:
mechanical barrier ….:
(see appended table 11.2)
P
11.2.5
Temperature rise of windings ………………:
(see appended table 11.2)
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5 ………………:
11.2.1 to 11.2.5 ………………:
No excessive temperature
observed/measured on
other parts.
(see appended table 11.2)
observed/measured on
other parts.
(see appended table 11.2)
P
- Page 14 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
12 Mechanical
strength
12.1.1
Bump test where mass >7 kg ……………………...:
No damage in the sense of
this standard
this standard
P
12.1.2
Vibration test …………………………………………:
Assessed to be satisfactory
constructed.
constructed.
N/A
12.1.3
Impact hammer test ………………………………...:
No damage in the sense of
this standard
this standard
P
Steel ball test ………………………………………...:
No damage in the sense of
this standard
this standard
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg:
Not portable apparatus
N/A
12.1.5
Thermoplastic enclosures stress relief test …….:
Tested, 70ºC, 7h
P
12.2
Fixing of knobs, push buttons, keys and levers ..:
Normal use will not impair the
protection against electric
shock.
protection against electric
shock.
P
12.3
Remote controls with hazardous live parts ….:
No cable connected
remote control devices.
remote control devices.
N/A
12.4
Drawers (pull test 50 N, 10 s) …………………:
No drawers
N/A
12.5
Antenna coaxial sockets providing isolation …:
No antenna
N/A
12.6
Telescoping or rod antennas construction …….:
No telescoping or rod antennas
N/A
12.6.1
Telescoping or rod antennas securement …….....:
N/A
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3 ………………:
See 13.3
P
Creepage distances in accordance with 13.4 …….:
See 13.4
P
13.2
Determination of operating voltage …..……:
Conventional
linear transf. used.
Rated supply voltage (240V)
applied in determining the
operating voltage.
applied in determining the
operating voltage.
P
13.3 Clearances
2N for internal parts and 30N
for enclosures are considered
when determining clearances.
for enclosures are considered
when determining clearances.
P
13.3.1 General
…………………………:
Considered
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ………..:
with table 8 and, where applicable, table 9 ………..:
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10 ……………...:
comply with table 10 ……………...:
No hazardous secondary
voltages
voltages
N/A
- Page 15 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
13.3.4
Measurement of transient voltages ………..:
No measurement of transient
voltages
voltages
N/A
13.4
Creepage distances ……………...:
CTI > 100
(see appended table 13)
(see appended table 13)
P
Creepage distances greater than table 11 minimum
values …………………...:
values …………………...:
Not applicable
N/A
13.5
Printed boards
Refer to below
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10 ……………………:
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10 ……………………:
No such PCB used
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only) ………..:
IEC 60664-3 (basic insulation only) ………..:
No type B coated printed
circuit boards
circuit boards
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4 ………….............:
clearances and creepage distances comply with
13.3 and 13.4 ………….............:
No uncemented joints
N/A
Conductive parts along reliably cemented joints
comply with 8.8 ………………:
comply with 8.8 ………………:
N/A
Temperature cycle test and dielectric strength test :
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12:
not conductively connected to the mains, clearances
and creepage distances as in table 12:
No enclosed, enveloped or
hermetically sealed parts
hermetically sealed parts
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8 ………………………:
requirements of 8.8 ………………………:
No parts filled with insulating
compound.
compound.
N/A
14 Components
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts ………………………………:
accessible metal parts ………………………………:
No such resistors
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
…………………………………..:
parts and accessible parts
…………………………………..:
Not used
N/A
Resistors separately approved ……………….:
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved ……………...……:
Yes, see below
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition …:
No Y capacitors
N/A
- Page 16 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition …:
Capacitors C904 certified
according to
IEC 60384-14, 2
according to
IEC 60384-14, 2
nd
edition,
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ………………:
connected to the mains: tests for X2 ………………:
No such capacitors
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ……:
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ……:
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ………………………:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ………………………:
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ………………………………………….:
metal ………………………………………….:
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4 …………….:
(as relevant) and clause 20.1.4 …………….:
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5
according to 14.3.3, 14.3.4
and 14.3.5
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type …………….:
manufacturer's name and type …………….:
Adequate marking applied.
Mfr, ID and type no.
Mfr, ID and type no.
P
Transformers and inductors separately approved ….:
No
N/A
14.3.2 General
……………………………:
Isolating transformers
P
Insulation material complies with clause 20.1.4 …:
Considered. The insulation
material of isolating transf.
complies with flammability
category of Table 21.
material of isolating transf.
complies with flammability
category of Table 21.
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13 ……………………………..:
clause 13 ……………………………..:
(see appended table 13)
P
14.3.3.2 Transformers
meet
the constructional requirements:
(see appended table 14.3.3)
P
14.3.4
Separation between windings
P
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
Double or reinforced
insulation between primary
and secondary windings
according to clause 8.8.
(see appended table 14.3.3)
insulation between primary
and secondary windings
according to clause 8.8.
(see appended table 14.3.3)
P
Coil formers and partition walls > 0,4 mm ……...:
Main and Sub transf. bobbin
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
P