- Page 13 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
11 Fault 
conditions 
 
11.1 
No shock hazard under fault condition ……………: 
No electric shock hazard under 
fault conditions. 
11.2 
Heating under fault condition ………………….: 
(see appended table 11.2) 
 
Flames extinguish within 10 seconds ..................: 
No flames 
 
No hazard from softening solder ……………...: 
No softening of solder 
 
Soldered terminations not used  as protective 
mechanism ………………………………..: 
No soldered terminations 
11.2.1 
Measurement of temperature rises ……..: 
(see appended table 11.2) 
11.2.2 
Temperature rise of accessible parts ……...: 
(see appended table 11.2) 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation ………: 
(see appended table 11.2) 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min ...: 
No exceeding the limits of 
Table 3. 
N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not more 
than 100 K for an area not greater than 2 cm² : 
 
N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min …………….: 
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted …...: 
No conductors are 
interrupted/peeled/loosened 
during fault conditions 
 
Class I protective earthing maintained ………….: 
Class II equipment 
N/A 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier ….: 
(see appended table 11.2) 
11.2.5 
Temperature rise of windings ………………: 
(see appended table 11.2) 
11.2.6 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.5 ………………: 
No excessive temperature  
observed/measured on  
other parts. 
(see appended table 11.2) 
 
 
 
- Page 14 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
12 Mechanical 
strength 
 
12.1.1 
Bump test where mass >7 kg ……………………...: 
No damage in the sense of  
this standard 
12.1.2 
Vibration test …………………………………………: 
Assessed to be satisfactory 
constructed. 
N/A 
12.1.3 
Impact hammer test ………………………………...: 
No damage in the sense of 
this standard 
 
Steel ball test ………………………………………...: 
No damage in the sense of  
this standard 
12.1.4 
Drop test for portable apparatus where mass ≤ 7 kg: 
Not portable apparatus 
N/A 
12.1.5 
Thermoplastic enclosures stress relief test …….: 
Tested, 70ºC, 7h 
12.2 
Fixing of knobs, push buttons, keys and levers ..: 
Normal use will not impair the 
protection against electric 
shock. 
12.3 
Remote controls with hazardous live parts ….: 
No cable connected  
remote control devices. 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) …………………: 
No drawers 
N/A 
12.5 
Antenna coaxial sockets providing isolation …: 
No antenna 
N/A 
12.6 
Telescoping or rod antennas construction …….: 
No telescoping or rod antennas 
N/A 
12.6.1 
Telescoping or rod antennas securement …….....: 
 N/A 
 
13 
Clearances and creepage distances 
 
13.1 
Clearances in accordance with 13.3 ………………: 
See 13.3 
 
Creepage distances in accordance with 13.4 …….: 
See 13.4 
13.2 
Determination of operating voltage …..……: 
Conventional 
linear transf. used. 
Rated supply voltage (240V)  
applied in determining the 
operating voltage. 
13.3 Clearances 
 
2N for internal parts and 30N 
for enclosures are considered 
when determining clearances. 
13.3.1 General 
…………………………: 
Considered 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9 ………..: 
(see appended table 13) 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 ……………...: 
No hazardous secondary 
voltages 
N/A 
 
 
- Page 15 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
13.3.4 
Measurement of transient voltages ………..: 
No measurement of transient 
voltages 
N/A 
13.4 
Creepage distances ……………...: 
CTI > 100 
(see appended table 13) 
 
Creepage distances greater than table 11 minimum 
values …………………...: 
Not applicable 
N/A 
13.5 
Printed boards  
Refer to below 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 ……………………: 
No such PCB used 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only) ………..: 
No type B coated printed  
circuit boards 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with  
13.3 and 13.4 ………….............: 
No uncemented joints 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 ………………: 
 
N/A 
 
Temperature cycle test and dielectric strength test : 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts 
not conductively connected to the mains, clearances 
and creepage distances as in table 12: 
No enclosed, enveloped or 
hermetically sealed parts 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 ………………………: 
No parts filled with insulating  
compound. 
N/A 
 
14 Components 
 
14.1 Resistors 
 
 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts ………………………………: 
No such resistors 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
…………………………………..: 
Not used
 
N/A 
 
Resistors separately approved ……………….: 
 
N/A 
14.2 
Capacitors and RC units  
 
 
Capacitors separately approved ……………...……: 
Yes, see below 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition …: 
No Y capacitors 
N/A 
 
 
- Page 16 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition …: 
Capacitors C904 certified 
according to 
IEC 60384-14, 2
nd
 edition, 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ………………: 
No such capacitors 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC60384-1, 4.38 category B or better ……: 
Several E. cap. Vol. >1750mm
3
,
but metal cases. 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 4.38 
category B or better ………………………: 
Several E. cap. Vol. >1750mm
3
,
but metal cases. 
N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal ………………………………………….: 
 N/A 
14.3 
Inductors and windings  
 P 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 …………….: 
Transformers evaluated  
according to 14.3.3, 14.3.4 
and 14.3.5 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type …………….: 
Adequate marking applied. 
Mfr, ID and type no. 
 
Transformers and inductors separately approved ….:
No 
N/A 
14.3.2 General 
……………………………: 
Isolating transformers 
 
Insulation material complies with clause 20.1.4 …: 
Considered.  The insulation 
material of isolating transf. 
complies with flammability 
category of Table 21. 
14.3.3 
Constructional requirements  
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 ……………………………..: 
(see appended table 13) 
14.3.3.2 Transformers 
meet 
the constructional requirements:
(see appended table 14.3.3) 
14.3.4 
Separation between windings 
 
 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) …………………...: 
Double or reinforced  
insulation between primary 
and secondary windings 
according to clause 8.8. 
(see appended table 14.3.3) 
 
Coil formers and partition walls > 0,4 mm ……...: 
Main and Sub transf. bobbin 
fulfils the requirement of 
reinforced insulation; bobbin 
thickness > 0,4 mm. 