- Page 21 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
15 Terminals 
 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard …………………………………...: 
Approved mains plug and 
socket-outlet provided. 
See appended table, list of 
critical components 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets …………..: 
Prevented by the fuse; 
F902 (T 2.5A L 250V) 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets ………….: 
Prevented by the fuse; 
F902 (T 2.5A L 250V) 
15.1.2 
Connectors for antenna, earth, audio, video or 
data .: 
 
 
No risk of insertion in mains socket-outlets ….: 
Only RCA, Antenna, Optical,  
HDMI, USB, Mini jack  
terminal used. 
Banana play type speaker  
terminal also used, but they 
are accepted due to below  
note. 
 
Note) Banana type speaker  
terminals are blocked in their 
axial holes to prevent use of  
plugs that can make  
permanent contact with a  
mains socket outlet. 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 …......................: 
No sockets indicated with  
the symbol 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-
outlets : 
The equipment under test is  
not an adaptor. 
N/A 
15.2 
Provision for protective earthing 
 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
Class II apparatus. 
N/A 
 
Protective earth conductors correctly coloured …..: 
 
N/A 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
….................................................................: 
 
N/A 
 
Protective earth terminal resistant to corrosion …..: 
 
N/A 
 
Earth resistance test: < 0,1 
Ω at 25 A ……….: 
 
N/A 
 
 
- Page 22 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 
N/A 
15.3.1 
Adequate terminals for connection of permanent 
wiring ……………………………………………...….: 
Apparatus is not for  
permanent connection 
N/A 
15.3.2 
Reliable connection of non-detachable cords …….: 
 P 
 
Not soldered to conductors of a printed circuit 
board : 
Not soldered 
 
Adequate clearances and creepage distances 
between connections should a wire break away …: 
Wires are clamped two times 
to the contact terminal and 
provided with a two-pole  
connector 
 
Wire secured by additional means to the conductor:
Adequately anchored. 
Tested with 5 N. 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar .: 
No screws and nuts clamping 
N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means ….:
No soldered conductors 
N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws ……………………………………: 
Clamped insulators and 
conductors 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment 
………………………………………….: 
Terminals have adequate  
connection capacity. 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16 :
 N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure ……………………………: 
No clamps. 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened ………………………..: 
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided ...……………...................: 
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic ……………………………: 
No contact pressure  
transmitted through insulating 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other …………………...: 
The termination of the 
contacts are in adequate  
proximity to each other. 
 
Terminals located and shielded: test with 8 mm 
strand ………………………………………: 
Clamped contacts within  
connector 
N/A 
 
 
- Page 23 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
15.4 
Devices forming a part of the mains plug  
 N/A 
15.4.1 
No undue strain on mains socket-outlets ……: 
The apparatus in not a  
device forming a part of the  
mains plug. 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs …………………………………….: 
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) ……………………………………….: 
 
N/A 
 
16 
External flexible cords 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ………………………….: 
Sheathed PVC cord  
complying with IEC 60227 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth ………………….: 
Class II apparatus 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment …………………………………: 
The cord is 0,75mm²,  
within the current rating 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength …………………………: 
No interconnecting cables  
comprising hazardous live  
conductors. 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of 
IEC 60227-2): 
Cord complying with 16.1. 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions ……………………….: 
Cords have adequate  
cross-sectional areas to avoid  
temperature rise under normal  
and fault conditions. 
16.5 
Adequate strain relief on external flexible cords …: 
Cord clip wedged in the 
enclosure 
 
Not possible to push cord back into equipment …..: 
Checked by inspection 
 
Strain relief device unlikely to damage flexible cord 
No sharp edges 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor 
Class II apparatus 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use …………………………………: 
No sharp edges 
 
 
- Page 24 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1 ………………………: 
The apparatus is not a  
transportable musical  
instrument and amplifier 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord ……………………...: 
 
N/A 
 
17 
Electrical connections and mechanical fixings 
 
17.1 
Torque test to table 20  
 
 
- screws into metal: 5 times ………………………...: 
see appended table 17.1 
 
- screws into non-metallic material: 10 times ……..: 
No non-metallic material 
N/A 
17.2 
Correct introduction into female threads in non-
metallic material ……………………………………..: 
No female threads in  
non-metallic materials 
N/A 
17.3 
Cover fixing screws: captive ………………………..: 
Captivity not necessary 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter ….:
Tested with screw with  
10 times diameter. 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A ………………………………………………..: 
Loosening is sufficiently 
prevented 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a current 
> 0,2 A ………………………………..: 
No contact pressure transmitted 
through insulating material. 
17.6 
Stranded conductors of flexible supply cords carrying 
a current > 0,2 A with screw terminals not 
consolidated by solder …………………: 
No screw terminals. 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous ……………………………………...: 
No cover fixing devices  
other than screws 
N/A 
17.8 
Fixing devices for detachable legs or stands 
provided ……………………………:  
No detachable provided 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected ……………..: 
Connections complies,  
checked by inspection 
 
Page of 65