- Page 25 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
 
 
Picture tube separately approved to IEC 61965 .: 
No CRT in the equipment. 
N/A 
 
Picture tube separately approved to 18.1 ..…….….: 
 
N/A 
18.1 
Picture tubes >16 cm intrinsically protected ….….: 
 
N/A 
 
Non-intrinsically protected tubes >16 cm used with 
protective screen ..…………………………......: 
 
N/A 
 
Protective film as part of implosion protection: edges 
covered by enclosure ..…………………...…: 
 
N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples : 
 
N/A 
18.2.1 
Samples subject to ageing: 6 samples ……………: 
 
N/A 
18.2.2 
Samples subject to implosion test: 6 samples …: 
 
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 samples ..…………………………………….: 
 
N/A 
18.3 
Non-intrinsically protected tubes tested to 18.3 ..: 
 
N/A 
 
19 
Stability and mechanical hazards 
 
 
Mass of the equipment exceeding 7 kg ..………….: 
Weight: 13.6kg 
 
 
Apparatus intended to be fastened in place – 
suitable instructions …………………………….….: 
No 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal …..:
Tested on a plane inclined at 
an angle of 10° 
19.2 
100 N force applied vertically downwards ..…….: 
100N force have no influence 
on the stability 
19.3 
100 N force, or 13% of weight, applied horizontally to 
point of least stability ….…………………………….: 
< 25 kg, < 1M 
N/A 
19.4 
Edges or corners not hazardous ……………….....: 
There is no hazardous edges  
or corners when the 
apparatus is operating in 
normal position 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension > 450 mm, 
pass the test of 19.5.1 …………………………: 
No glass surface. 
N/A 
19.6 
Wall or ceiling mountings adequate ………….: 
Not intended for wall or ceiling 
mounting 
N/A 
 
 
 
- Page 26 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
20 
Resistance to fire 
 
20.1 
Electrical components and mechanical parts  
 N/A 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width …………: 
 N/A 
 
b) Exemption for small components as defined in 
20.1 ………………………………………………...: 
PCB is of flammability class  
V-0 or better, and exception  
is made for small components. 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4 ……………………………....: 
Electrical components comply 
with flammability requirements in 
clause 14. 
N/A 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire …………………...: 
No wires working at  
voltages > 4kV or leaving 
an internal fire enclosure 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC60707, unless used in a fire 
enclosure ..: 
All PCB is of base material 
with flammability category 
V-0 or batter.  
See appended table, list of 
critical components 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 ………: 
No voltage exceeding 400V 
(peak) a.c. or d.c. 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 20.1.2 
and 20.1.3 (other than fire enclosures) mounted 
nearer to a potential ignition source than the 
distances in Table 21 comply with the relevant 
flammability category in Table 21 ………………….: 
Bobbin of transformers, rated 
94V-0. 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 ……………..: 
No such components 
N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure ………………………………………..…...: 
Normal operating voltage 
< 4KV  
N/A 
 
 
- Page 27 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
20.2 Fire 
enclosure 
 
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 …………………………………..: 
No voltages exceeding  
4kV, no fire enclosure  
requirement 
N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires 
completely filled ……………………………………..: 
No internal fire enclosure. 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure ……………………………….: 
No internal fire enclosure. 
N/A 
 
 
 
- Page 28 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
 
A.5 Marking 
and 
instructions 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply …………………………….....: 
Not intended for outdoor use 
N/A 
A.10.2 Insulation 
requirements 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water ..................................................: 
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days …………:   
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS 
 
 
Complies with IEC 62151 clause 1 …………………..:
No TNV circuits 
N/A 
 
Complies with IEC 62151 clause 2 …………………..:
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
………………...…: 
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard …………………………………: 
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard ………………………………………...…: 
 
N/A 
 
Complies with IEC 62151 clause 6 …………………..:
 
N/A 
 
Complies with IEC 62151 clause 7 ………………...: 
 
N/A 
 
Complies with IEC 62151 annex A, B and C ……….:
 
N/A 
 
Page of 65