DOWNLOAD Harman Kardon AVR 270 (serv.man2) Service Manual ↓ Size: 7.37 MB | Pages: 107 in PDF or view online for FREE

Model
AVR 270 (serv.man2)
Pages
107
Size
7.37 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-270-sm2.pdf
Date

Harman Kardon AVR 270 (serv.man2) EMC - CB Certificate ▷ View online

 
Page 29 of 61 
Report No.: 215444 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
20.2 Fire 
enclosure 
 
 
N/A 
20.2.1 Potential 
ignition 
sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
No voltage > 4 kV (peak) 
N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires 
completely filled  
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 
N/A 
 
Page 30 of 61 
Report No.: 215444 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
 
A.5 Marking 
and 
instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
Not intended for outdoor use 
N/A 
A.10 Insulation 
requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION 
NETWORKS 
 
 
Complies with IEC 62151 clause 1  
No TNV circuits 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard  
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
 
Page 31 of 61 
Report No.: 215444 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
 
L. 5 
Marking and instructions 
 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
No electronic flash apparatus 
N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 
N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
L7.1.5 & 
L11.2.7 
Lithium batteries meet permissible temp rise in 
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC 
60086-4  
No lithium batteries 
N/A 
L. 9 
Electric shock hazard under normal operating 
conditions 
Not flash synchroniser. 
N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 
N/A 
L.10 Insulation 
requirements 
 
N/A 
L. 10.3.2 
High frequency pulse ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel ball 
impact test  
 
N/A 
L. 14 
Components 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 
N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c)  Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 
N/A 
 
Page 32 of 61 
Report No.: 215444 
 
 
TRF No. IEC60065K 
7.1 
TABLE: temperature rise measurements:  
 
Power consumption in the OFF/Stand-by mode of 
the functional switch (W)  ........................................ : 
Less than 0.44 W 
— 
 
Operating Condition / Status 
Standby mode; 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
Uout (V) rms 
Pout (W) 
1 220  50 
0.086 
0.32 
2 240  50 
0.070 
0.35 
3 264  50 
0.076 
0.41 
4 220  60 
0.076 
0.32 
5 240  60 
0.083 
0.37 
6 264  60 
0.091 
0.44 
 
 
 
 
 
 
 
**) Measured at maximum non-clipped output mode with loaded 5 V/2.1 A through USB terminal; 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
Uout (V) rms 
Pout (W) 
7 198  50 
3.97 
524.5 
F) 15.11 V x 2 ch. 
SB) 14.60 V x 2 ch. 
S) 14.96 V x 2 ch. 
C) 14.55 V x 1 ch. 
F) 38.05 W x 2 ch. 
SB) 35.53 W x 2 ch.
S) 37.30 W x 2 ch. 
C) 35.28 W x 1 ch. 
8 264  50 
2.92 
513.8 
9 198  60 
3.83 
524.2 
10 264  60 
2.87 
514.5 
 
 
 
 
 
 
 
*) Measured at 1/8 of maximum non-clipped output mode with loaded 5 V/2.1 A through USB terminal; 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
Uout (V) rms 
Pout (W) 
11 198  50 
2.60 
338.6 
F) 5.34 V x 2 ch. 
SB) 5.16 V x 2 ch. 
S) 5.29 V x 2 ch.  
C) 5.14 V x 1 ch. 
F) 4.75 W x 2 ch. 
SB) 4.44 W x 2 ch. 
S) 4.66 W x 2 ch. 
C) 4.41 W x ch. 
12 220  50 
2.41 
337.9 
13 240  50 
2.20 
337.3 
14 264  50 
1.98 
337.0 
15 198  60 
2.57 
342.1 
16 220  60 
2.38 
341.8 
17 240  60 
2.19 
341.5 
18 264  60 
1.97 
341.2 
Page of 107