DOWNLOAD Harman Kardon AVR 270 (serv.man2) Service Manual ↓ Size: 7.37 MB | Pages: 107 in PDF or view online for FREE

Model
AVR 270 (serv.man2)
Pages
107
Size
7.37 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-270-sm2.pdf
Date

Harman Kardon AVR 270 (serv.man2) EMC - CB Certificate ▷ View online

 
Page 21 of 61 
Report No.: 215444 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
Double or reinforced insulation 
between hazardous live 
windings and accessible 
conductive parts 
 
Coil formers and partition walls > 0,4 mm  
>0.4 mm 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
Winding of Class II  
construction used. 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 
N/A 
14.4 
High voltage components  
No high-voltage components. 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 
N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 
N/A 
14.5 Protective 
devices 
 
 
 
Protective devices used within their ratings  
Certified fuse used. 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
Certified fuse used. 
See appended table, 
list of critical components. 
14.5.1.1 
a) Thermal cut-outs separately approved  
TS91 and TS92 approved 
component according to 
IEC 60730-1. 
See appended table, list of 
critical components. 
 
b) Thermal cut-outs tested as part of the submission  
N/A 
14.5.1.2 
a) Thermal links separately approved  
No thermal links 
N/A 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
No soldering. 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
Fuse is approved component 
according to  
IEC 60127. 
See appended table, list of 
critical components. 
 
Page 22 of 61 
Report No.: 215444 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... : 
The following marking applied; 
F901: T6.3A H 250V
 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : 
No fuses holder so designed 
that fuse-links can be  
connected in parallel. 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ......... : 
No replacement of fuse  
possible by hand. 
14.5.3 
PTC thermistors comply with IEC 60730-1:2007 
No PTC’s 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked  
Only standard fuse used. 
N/A 
14.6 Switches 
 
 
14.6.1 a) 
Separate testing to IEC 61058-1 including: 
- 10 000 operations 
- Normal pollution suitability 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
Mains switch used 
Certified by FIMKO 
 
See appended table, list of 
critical components 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 N/A 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 N/A 
 
Switch controlling < 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with  14.6.4 and  
V-0 in annex G, G.1.1  
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use  
 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 
N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1  
No mains socket outlets, but 
peak inrush current measured  
to 41.5A, switch rated 100A. 
 
See appended table, list of  
critical components. 
P 
 
Socket outlet current marking correct  
No mains socket outlet. 
N/A 
 
Page 23 of 61 
Report No.: 215444 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.7 
Safety interlocks  
No safety interlocks. 
N/A 
 
Safety interlocks to 2.8 of IEC 60950-1 
 
N/A 
14.8 
Voltage setting devices and the like  
No voltage setting devices. 
N/A 
 
Voltage setting device not likely to be changed 
accidentally  
 
N/A 
14.9 Motors 
No AC motors,  
Brushless DC fan motor only.  
14.9.1 
Endurance test on motors  
 
N/A 
 
Motor start test  
 
N/A 
 
Dielectric strength test  
Only DC supplied. 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.   
The motor for fans are not 
adversely affected by oil, 
grease or other substances. 
14.9.3 
Protection against moving parts  
The fans are placed inside the 
unit. No access. 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950-1, Annex B  
 
N/A 
14.10 Batteries 
 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases  
No batteries. 
N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries  
 
N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits  
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits  
 
N/A 
14.10.4 
Battery mould stress relief  
 
N/A 
14.10.5 
Battery drop test  
 
N/A 
14.11 Optocouplers 
 
Approved 
optocouplers. 
Internal/external creepage 
and clearance distances are 
>4 mm / >5 mm, or no internal 
creepage/clearance distance, 
however thermal cycling test  
is covered. 
See appended table, list of 
critical components. 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 
 
b) Comply with IEC 60747-5-5:2007 
 
N/A 
 
Page 24 of 61 
Report No.: 215444 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Alternative to a) and b) optocoupler comply with 13.8  
N/A 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 
14.12 
Surge suppression varistors  
 
 
Comply with IEC 61051-2  
Varistor, VT91 and VT92. 
Comply with IEC 61051-2. 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus  
No such application 
N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
A certified varistors used. 
 
15 Terminals 
 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard  
Approved appliance inlet and 
cord set provided. 
 
See appended table,  list of  
critical components 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets  
No mains socket-outlets 
N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets  
No mains socket-outlets 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or  
data  
 
 
No risk of insertion in mains socket-outlets  
Only RCA, Antenna, Optical,  
Network, RS232C, Mini jacks 
and HDMI terminal used. 
Banana plug type speaker 
terminal also used, but they 
are accepted due to below 
note. 
 
Note) Banana type speaker 
terminals are blocked in their 
axial holes to prevent use of 
plugs that can make 
permanent contact with a 
mains socket outlet. 
 
No risk of insertion into audio- or video- outlets 
marked with the symbol of 5.2  
No sockets indicated with  
the symbol 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets 
Not adaptors used 
N/A 
15.2 
Provision for protective earthing 
 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
Class II apparatus. 
N/A 
Page of 107
Display