EMC - CB Certificate
Brand
Device
Audio
File
avr-270-sm2.pdf
Date

Harman Kardon AVR 270 (serv.man2) EMC - CB Certificate ▷ View online

 
Page 33 of 61 
Report No.: 215444 
 
 
TRF No. IEC60065K 
Operating Condition / Status 
**) Measured at 1/8 of maximum non-clipped output mode with loaded 5 V/2.1 A through USB terminal; 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
Uout (V) rms 
Pout (W) 
19 198  50 
1.70 
215.3 
F) 5.34 V x 2 ch. 
SB) 5.16 V x 2 ch. 
S) 5.29 V x 2 ch. 
C) 5.14 V x 1 ch. 
F) 4.75 W x 2 ch. 
SB) 4.44 W x 2 ch. 
S) 4.66 W x 2 ch. 
C) 4.41 W x 1 ch. 
20 220  50 
1.57 
215.5 
21 240  50 
1.45 
215.8 
22 264  50 
1.31 
216.2 
23 198  60 
1.68 
217.4 
24 220  60 
1.55 
216.8 
25 240  60 
1.43 
216.1 
26 264  60 
1.29 
216.0 
Input measured at TF95 and TF96 transformer outputs of;        *) HIGH mode        **) LOW mode 
(see summary of testing) 
Tested condition: 1 kHz input signal, connected 6 ohm loads for F, SB, S, C channels. 
 
Loudspeaker impedance (Ω)  .................................. :
6 Ohms 
— 
 
Several loudspeaker systems ................................. :
Right and Left for Front, 
Right and Left for Surround Back, 
Right and Left for Surround, 
Only one for Center. 
 
Marking of loudspeaker terminals ........................... :
SPEAKERS (6 Ω ~ 8 Ω) 
 
 
 
 
 
Page 34 of 61 
Report No.: 215444 
 
 
TRF No. IEC60065K 
Temperature Rise dT of Part 
dT (K) 
Limit max 
dT (K) *) 
Test Condition No. 
No. 14 
No. 22 
No. 18 
No. 26 
Transformer, TF91 coil 
30.2 
38.2 
24.1 
39.6 
85   **) 
Transformer, 
TF91 
core 
27.5 35.4 21.3 36.9 95 
Transformer, TF92 coil 
34.5 
44.8 
32.2 
45.7 
85   **) 
Transformer, 
TF92 
core 
29.9 39.5 27.7 40.4 95 
Transformer, TF95 coil 
51.3 
57.6 
49.2 
58.2 
85   **) 
Transformer, 
TF95 
core 
39.4 49.9 36.9 50.7 95 
Transformer, TF96 coil 
57.4 
66.4 
54.9 
65.6 
85   **) 
Transformer, 
TF96 
core 
46.5 59.2 43.5 58.8 95 
Line filter, LF91 coil 
23.0 
27.1 
21.9 
27.9 
60   **) 
Line filter, LF92 coil 
22.4 
26.4 
21.1 
27.2 
60   **) 
Line filter, LF93 coil 
20.1 
26.0 
19.1 
26.8 
60   **) 
PFC inductor, CLZ9Z148Z coil 
34.7 
39.4 
28.2 
41.1 
60   **) 
PFC inductor, CLZ9Z148Z core 
32.0 
39.1 
26.0 
41.0 
70 
Body of DB91 
44.9 
40.2 
44.4 
41.0 
PWB near DB91 
22.4 
25.2 
21.7 
25.9 
95 
Body of Q910 
34.0 
46.1 
31.8 
42.5 
PWB near Q910 
31.8 
42.5 
29.7 
40.1 
95 
Heat-sink of Q910 
30.9 
41.9 
29.1 
39.1 
Body of C930 
29.9 
35.3 
27.2 
34.3 
105 
o
Body of connector, CN90 
20.0 
27.2 
19.0 
27.8 
Body of connector, CN91 
21.3 
25.9 
20.5 
26.6 
Body of connector, SW91 
22.9 
25.1 
22.3 
26.1 
Body of connector, SW92 
23.3 
29.7 
22.3 
30.5 
Heat-sink of D956 
47.7 
61.8 
47.9 
64.1 
PWB near D956 
38.5 
47.7 
37.6 
49.3 
95 
Body of C966 
34.4 
43.6 
32.5 
45.5 
105 
o
Body of Q654 
54.4 
45.9 
54.5 
45.8 
PWB near Q654 
29.2 
27.3 
29.1 
28.3 
95 
Body of C916 
13.6 
18.1 
12.7 
19.1 
85 
o
Main 
heat-sink 
39.2 38.4 39.3 38.2 - 
 
 
Page 35 of 61 
Report No.: 215444 
 
 
TRF No. IEC60065K 
Temperature Rise dT of Part  
(continued)
 
dT (K) 
Limit max 
dT (K) *) 
Test Condition No. 
No. 14 
No. 22 
No. 18 
No. 26 
FAN body (installed in main heat-sink) 
14.1 
12.7 
11.9 
13.8 
FAN body (installed in back cover inside) 
13.8 
19.0 
13.5 
20.1 
Appliance 
inlet 
body 
7.4 11.1 7.5 12.2 60 
Main switch body (non-metallic) 
6.3 
10.1 
6.1 
11.2 
50 
Stand-by button (non-metallic) 
1.7 
3.8 
1.1 
4.9 
50 
Front cover (metallic) 
2.6 
5.3 
1.9 
6.4 
40 
Top cover above main transf.(metallic) 
12.2 
13.8 
12.7 
14.8 
40 
Top cover above Heat-sink (metallic) 22.5 23.2 22.4 23.8 40 
Ambient 26.0 
o
C 25.5 
o
C 25.8 
o
C 25.3 
o
C - 
 
 
 
 
 
 
*) Temperature rise limits for tropical climate is 10K less.  
**) Minus (-) 10 K applied for thermo-couple method for windings. 
Tested condition; 
Wall condition: 30 cm top and other sides 
USB port loaded output: 2.6 A loaded through USB port (2.6A is achievable MAX load continuously).  
 
 
 
 
Page 36 of 61 
Report No.: 215444 
 
 
TRF No. IEC60065K 
Temperature Rise dT of Part 
dT (K) 
Limit max 
dT (K) *) 
Test Condition No. 
No. 11 
No. 19 
No. 15 
No. 23 
Transformer, TF91 coil 
31.6 
39.4 
26.6 
40.7 
85   **) 
Transformer, 
TF91 
core 
28.7 36.5 23.9 37.8 95 
Transformer, TF92 coil 
36.0 
45.5 
34.3 
46.3 
85   **) 
Transformer, 
TF92 
core 
31.2 40.1 30.1 40.8 95 
Transformer, TF95 coil 
50.5 
56.5 
50.7 
57.3 
85   **) 
Transformer, 
TF95 
core 
40.1 49.5 39.3 50.3 95 
Transformer, TF96 coil 
55.3 
62.8 
55.7 
63.7 
85   **) 
Transformer, 
TF96 
core 
45.8 56.5 46.0 57.3 95 
Line filter, LF91 coil 
27.1 
31.3 
26.8 
31.8 
60   **) 
Line filter, LF92 coil 
26.9 
30.7 
26.1 
31.2 
60   **) 
Line filter, LF93 coil 
23.9 
29.5 
23.5 
30.2 
60   **) 
PFC inductor, CLZ9Z148Z coil 
44.3 
46.3 
39.3 
47.8 
60   **) 
PFC inductor, CLZ9Z148Z core 
37.1 
44.0 
32.4 
45.5 
70 
Body of DB91 
57.4 
49.2 
56.6 
49.9 
PWB near DB91 
27.2 
28.8 
26.6 
29.6 
95 
Body of Q910 
31.8 
38.8 
31.2 
40.0 
PWB near Q910 
30.6 
37.3 
30.1 
38.8 
95 
Heat-sink of Q910 
29.4 
36.0 
28.9 
37.2 
Body of C930 
31.5 
37.3 
31.2 
36.6 
105 
o
Body of connector, CN90 
22.9 
29.2 
22.4 
29.8 
Body of connector, CN91 
24.8 
28.6 
24.3 
29.4 
Body of connector, SW91 
27.3 
29.3 
27.0 
29.7 
Body of connector, SW92 
25.2 
31.0 
24.7 
31.7 
Heat-sink of D956 
50.6 
64.0 
50.1 
64.8 
PWB near D956 
39.7 
48.7 
39.5 
49.7 
95 
Body of C966 
35.8 
45.1 
36.0 
45.9 
105 
o
Body of Q654 
55.8 
46.5 
55.7 
47.6 
PWB near Q654 
30.7 
28.9 
30.4 
29.4 
95 
Body of C916 
15.2 
19.7 
14.7 
20.1 
85 
o
Main 
heat-sink 
40.4 38.7 40.4 39.9 - 
 
Page of 107