Report No.: 215444 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
Constructional requirements with regard to the protection against electric 
shock 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
Considered 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
Operation “By hand” not 
possible. 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
No hygroscopic materials used 
N/A 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
No cover removable by hand. 
N/A 
8.5 
Class I equipment  
Class II equipment 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
Class II equipment 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
Double/Reinforced insulation 
complies with requirements 
specified in clause 10 and 13. 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
The apparatus have isolated  
transformer complies with  
clause 14.3. 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
No such components 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
No such capacitors. 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
No such capacitors. 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
CY91, CY92, CY93, CY94, 
CY95 and CY96 capacitors, 
bridging reinforced insulation 
in the apparatus. 
8.7 
This clause is void  
 
 
 
Page 14 of 61 
Report No.: 215444 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
Tubing (thickness 
≥0.4 mm) 
for TS91, TS92 lead wires. 
Complies with clause 10.3. 
 
Reinforced insulation > 0,4 mm (mm)  .................... : 
a. Transformers and PFC 
inductor ref. 14.3. 
b. Optocouplers inner 
insulation, ref. 14.11. 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
Insulation in TF91, TF92, 
TF95 and TF96 transformers. 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3  
3 layers insulation tape used 
in TF91, TF92, TF95, TF96 
transformer between, 
- pri. and sec. winding, 
- pri. and iron core (ic). 
- sec. and iron core (ic). 
(see appended table 14.3.3). 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
Double insulated 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts 
Single insulated but safely  
anchored. 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
Double insulated according to 
8.9 and 10.3 
 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts.
Single insulated but safely  
anchored. 
N/A 
8.11 
Detaching of wires  
 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
Inlet connected wires 
hooked-in before soldered. 
Other primary wires connected 
with multi-contact housing. 
 Vibration 
test 
carried out  ........................................ : 
See clause 12.1.2 
N/A 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
Adequately fastened. 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
Covers adequately fastened  
with screws. 
 
Page 15 of 61 
Report No.: 215444 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
Wires safely anchored away 
from parts with high 
temperature 
8.16 
Only special supply equipment can be used  
No special supply apparatus. 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
No such winding wire. 
N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
See below 
8.19.1 Disconnect 
device 
 
Appliance coupler is used as 
disconnect devices. 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
All pole mains switch provided, 
however not considered as 
disconnecting device. 
N/A 
8.19.2 
Mains switch ON indication  
LED for ON indication  
provided. 
8.20 
Switch not fitted in the mains cord  
No switch in the mains cord. 
8.21 
Bridging components comply with clause 14  
 
N/A 
8.22 
Non-separable thin sheet material  
 
N/A 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
P 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltages >1000 V ac or  
>1500 V dc 
N/A 
9.1.1.1 
a) Open circuit voltages  
Mains input voltage 
> 35 Vac, see below. 
 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. : 
U1: Max. 1.40 Vpeak 
U2: Max. 0.32 Vpeak 
(Tested at 264 V) 
 
c) Discharge not exceeding 45 μC  
No part or contact of a  
terminal with stored voltages 
between 60V - 15 kV. 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
No part or contact of a 
terminal with stored voltages 
exceeding 15kV. 
N/A 
9.1.1.2 
Test with test finger and test probe  
No access to hazardous 
live parts 
9.1.2 
No hazardous live shafts of knobs, handles or levers  No live shafts of knobs, 
handles or levers. 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No access for the test pin. 
 
Page 16 of 61 
Report No.: 215444 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
Does not reach hazardous 
live parts 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
Does not reach hazardous 
live parts 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No pre-set controls 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
0 V after 2 s, 
Bleeder resistor provided. 
See clause 14.1 b), and 
appended table, list of critical 
components. 
 
If C is not greater than 0,1 μF no test needed  
> 0.1  μF 
 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
Test with test finger result 
in no hazard. 
 
b) Test hook of fig. 4 for 10 s (20 N)  
Test with test hook results 
in no hazard. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
Test with test tool results 
in no hazard. 
9.2 
No hazard after removing a cover by hand  
No cover removable by hand 
N/A 
 
10 Insulation 
requirements 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ................................................................. : 
Basic: >2.6 MΩ, 
Reinforced: >5.2 MΩ after 
surge test 
10.2 Humidity 
treatment 
48 h or 120 h  .......................... : 
Performed for 120 h at temp. 
40
C and humidity 93% 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table 10.3) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
Class II apparatus 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
(see appended table 10.3) 
 