Harman Kardon AVR 270 (serv.man2) EMC - CB Certificate ▷ View online
Page 9 of 61
Report No.: 215444
TRF No. IEC60065K
Name and address of factory (ies) .......................... : Factory 1:
Anam Electronics (Dongguan) Co., Ltd.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China.
Factory 2:
DongGuan LiaoBu Anam Electronics.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China.
Factory 2:
DongGuan LiaoBu Anam Electronics.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China.
General product information:
The apparatus under test is A/V Surround Receiver of insulation class II.
The apparatus has amplifier circuits (Front, Surround, Surround back and Center), Tuner circuit, Several
Signal I/O terminals (Phones, RCA, OPTICAL, USB, RS-232C, NETWORK, mini jacks and HDMI)
and Speaker terminals - (See also photos).
The model, AVR 270/230 is basic model.
The model, AVR 270/230C is identical to tested basic model AVR 270/230 except for model
designation with marking drawing.
The apparatus under test is A/V Surround Receiver of insulation class II.
The apparatus has amplifier circuits (Front, Surround, Surround back and Center), Tuner circuit, Several
Signal I/O terminals (Phones, RCA, OPTICAL, USB, RS-232C, NETWORK, mini jacks and HDMI)
and Speaker terminals - (See also photos).
The model, AVR 270/230 is basic model.
The model, AVR 270/230C is identical to tested basic model AVR 270/230 except for model
designation with marking drawing.
Page 10 of 61
Report No.: 215444
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
3 General
requirements
Safety class of the apparatus .................................. :
Class II apparatus.
P
4
General test conditions
4.1.4
Ventilation instructions require the use of the test
box
box
Tested in a wooden test box
according to instructions in
manual.
(Tested box condition: 30 cm
for top and other sides.)
according to instructions in
manual.
(Tested box condition: 30 cm
for top and other sides.)
P
5
Marking and instructions
Comprehensible and easily discernible
On front and rear side of
the enclosure
the enclosure
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / petroleum
sprit
sprit
P
5.1
a) Identification, maker ............................................ : Trade mark:
P
b) Model number or type reference.......................... : Model no. : AVR 270/230,
AVR 270/230C
See copy of marking plate.
See copy of marking plate.
P
c) Class II symbol if applicable ................................ : Class II symbol is applied in
according to IEC 60417-5172
P
d) Nature of supply ................................................... : a.c. symbol is applied in
according to IEC 60417-5032
P
e) Rated supply voltage ........................................... : 220-240 V~
P
f) Mains frequency if safety dependant ................... : 50/60 Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ............................................................................ :
apparatus supplied by supply apparatus for general
use ............................................................................ :
The apparatus is connection
to an a. c. mains supply.
to an a. c. mains supply.
N/A
Measured current or power consumption ............... :
N/A
Deviation
%
(max 10%) ........................................... :
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply :
us intended for connection to an a.c. mains supply :
370 W
P
Measured current or power consumption ............... : Max. 341.8 W
(see appended table 7.1)
P
Measured current or power consumption for
Television set ........................................................... :
Television set ........................................................... :
No television set.
N/A
Deviation
%
(max
10%) ........................................... : Not exceed the marked value
P
5.2
a) Earth terminal
Class II apparatus.
N/A
Page 11 of 61
Report No.: 215444
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
b) Hazardous live terminals
No hazardous live terminals.
The output signal will rise to
22.4 Vp at maximum out
power if the speaker load is
disconnected in the speaker
terminal, No hazard.
The output signal will rise to
22.4 Vp at maximum out
power if the speaker load is
disconnected in the speaker
terminal, No hazard.
P
c) Markings on supply output terminals
No socket outlet for providing
power to other apparatus
power to other apparatus
N/A
5.3
a) Use of triangle with exclamation mark
Correct symbol applied:
- In rear side in connection
with CAUTION of opening
- In circuit diagram.
Further, no incorrect use of
this symbol is found.
- In rear side in connection
with CAUTION of opening
- In circuit diagram.
Further, no incorrect use of
this symbol is found.
P
b) marking on loudspeaker grille, IEC 60417-5036
Not used loudspeaker grille
N/A
5.4
Instructions for use
User information in the
following language:
English and Chinese.
See comments in Summary
of Testing.
following language:
English and Chinese.
See comments in Summary
of Testing.
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
The user manual includes
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
P
b) Hazardous live terminals, instructions for wiring
No hazardous live terminals
N/A
c) Instructions for replacing lithium battery
No battery
N/A
d) Class I earth connection warning
Class II apparatus
N/A
e) Instructions for multimedia system connection
Instructions for multimedia
system connection provided
in user manual.
system connection provided
in user manual.
P
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
No such equipment
N/A
g) Warning: battery exposure to heat
No such equipment
N/A
h) Warning: protective film on CRT face
No CRT
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Appliance coupler is
disconnecting device and
readily operable.
disconnecting device and
readily operable.
P
c) Instructions for permanently connected equipment Not permanent connected
equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
Considered.
P
Page 12 of 61
Report No.: 215444
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
6 Hazardous
radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1:2007
.................................................................................. :
.................................................................................. :
No laser radiation
N/A
Emission limits under fault conditions ..................... :
N/A
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
No fuse links operate during
normal operating operation.
(see appended table 7.1)
normal operating operation.
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
1. Appliance inlet certified
according to IEC 60320-1
2. PCB: Epoxy or Phenol
3. Transf. and Line filter
according to IEC 60320-1
2. PCB: Epoxy or Phenol
3. Transf. and Line filter
(LF93)
Bobbins (or Coil base) are
Phenolic except for Line
filters
filters
(LF91,
LF92).
See appended table 7.2 for
AC connectors (CN90, CN91,
SW91, SW92) and Coil base
of Line filters (LF91, LF92).
AC connectors (CN90, CN91,
SW91, SW92) and Coil base
of Line filters (LF91, LF92).