Harman Kardon AVR 265 EMC - CB Certificate ▷ View online
Page 10 of 11
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
5.4.1
Norway and Sweden
To the end of 5.4.1 (after the compliance statement) the
following is added:
The screen of the cable distribution system is normally
not earthed at the entrance of the building and there is
normally no equipotential bonding system within the
building. Therefore the protective earthing of the building
installation need to be isolated from the screen of a
cable distribution system.
It is however accepted to provide the insulation external
to the equipment by an adapter or an interconnection
cable with galvanic isolator, which may be provided by
e.g. a retailer.
The user manual shall then have the following or similar
information in Norwegian and Swedish language
respectively, depending on in what country the
equipment is intended to be used in:
“Equipment connected to the protective earthing of the
building installation through the mains connection or
through other equipment with a connection to protective
earthing – and to a cable distribution system using
coaxial cable, may in some circumstances create a fire
hazard. Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)”
NOTE In Norway, due to regulation for installations of
cable distribution systems, and in Sweden, a galvanic
isolator shall provide electrical insulation below 5 MHz.
The insulation shall withstand a dielectric strength of 1,5
kV r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will also be
accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via nettplugg
og/eller via annet jordtilkoplet utstyr – og er tilkoplet et
kabel-TV nett, kan forårsake brannfare. For å unngå
dette skal det ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret og
kabel-TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och samtidigt är
kopplad till kabel-TV nät kan i vissa fall medfőra risk főr
brand.
Főr att undvika detta skall vid anslutning av utrustningen
till kabel-TV nät galvanisk isolator finnas mellan
utrustningen och kabel-TV nätet.”
To the end of 5.4.1 (after the compliance statement) the
following is added:
The screen of the cable distribution system is normally
not earthed at the entrance of the building and there is
normally no equipotential bonding system within the
building. Therefore the protective earthing of the building
installation need to be isolated from the screen of a
cable distribution system.
It is however accepted to provide the insulation external
to the equipment by an adapter or an interconnection
cable with galvanic isolator, which may be provided by
e.g. a retailer.
The user manual shall then have the following or similar
information in Norwegian and Swedish language
respectively, depending on in what country the
equipment is intended to be used in:
“Equipment connected to the protective earthing of the
building installation through the mains connection or
through other equipment with a connection to protective
earthing – and to a cable distribution system using
coaxial cable, may in some circumstances create a fire
hazard. Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)”
NOTE In Norway, due to regulation for installations of
cable distribution systems, and in Sweden, a galvanic
isolator shall provide electrical insulation below 5 MHz.
The insulation shall withstand a dielectric strength of 1,5
kV r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will also be
accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via nettplugg
og/eller via annet jordtilkoplet utstyr – og er tilkoplet et
kabel-TV nett, kan forårsake brannfare. For å unngå
dette skal det ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret og
kabel-TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och samtidigt är
kopplad till kabel-TV nät kan i vissa fall medfőra risk főr
brand.
Főr att undvika detta skall vid anslutning av utrustningen
till kabel-TV nät galvanisk isolator finnas mellan
utrustningen och kabel-TV nätet.”
Class II apparatus
N/A
Page 11 of 11
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
15.1.1 Denmark
The text of the Danish SNC in EN 60065:2002 has
been modified as follows:
been modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase appliances
having a rated current not exceeding 13 A shall be
provided with a plug according to the Heavy Current
Regulations Section 107-2-D1.
having a rated current not exceeding 13 A shall be
provided with a plug according to the Heavy Current
Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used in
locations where protection against indirect contact is
required according to the wiring rules shall be
provided with a plug in accordance with the Heavy
Current Regulations, Section 107-2-D1 standard
sheet DK 2-1a.
with earth contact or which are intended to be used in
locations where protection against indirect contact is
required according to the wiring rules shall be
provided with a plug in accordance with the Heavy
Current Regulations, Section 107-2-D1 standard
sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to CLASS
II apparatus with a rated current of 2,5 A shall be in
accordance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-4a.
II apparatus with a rated current of 2,5 A shall be in
accordance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA
1-3b.
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA
1-3b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a
or DK 1-7a.
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a
or DK 1-7a.
Justification: Heavy Current Regulations, Section
107-2-D1
107-2-D1
No socket-outlet.
N/A
Page 1 of 5
Report No.: 163977
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
ANNEX TO TEST REPORTS
REGULATORY REQUIREMENTS FOR SINGAPORE
Annex Form No. .............................. : SG_RR_A
Annex Form Originator ..................... : TÜV SÜD PSB Pte Ltd
Master Annex Form .......................... : 2008-03
Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
(IECEE), Geneva, Switzerland. All rights reserved.
No Items
Requirements
Result - Remark
Verdict
The following is the national differences in accordance with safety authority website
www.spring.gov.sg/safety, ref. Singapore Consumer Protection (Safety Requirements) – Information
Booklet – Chapter 7.
www.spring.gov.sg/safety, ref. Singapore Consumer Protection (Safety Requirements) – Information
Booklet – Chapter 7.
7 SAFETY AUTHORITY’S REQUIREMENTS
The Safety Authority monitors the safety of the controlled goods sold in Singapore by investigating
all complaints, incidents and accidents reported to the authority. Experiences gained are translated
into the Safety Authority’s Requirements. These requirements are to be fulfilled in addition to the
applicable safety standards.
all complaints, incidents and accidents reported to the authority. Experiences gained are translated
into the Safety Authority’s Requirements. These requirements are to be fulfilled in addition to the
applicable safety standards.
No Items
Requirements
Result - Remark
Verdict
Applicable to all products
1
Test certificate /
Test report
Test report
Test certificate / Test report more
than three (3) years old shall be
rejected.
than three (3) years old shall be
rejected.
Noted
—
Applicable to all electrical products
2 All
appliances
All appliances must be tested to 230
VAC.
VAC.
230 Vac covered.
P
3 Voltage
selector
(voltage mis-
match test)
match test)
Appliance fitted with voltage
selector shall be tested as follows:
selector shall be tested as follows:
Connect appliance to 230 VAC
mains with voltage selector switch
to settings not suitable for operation
at 230 VAC.
mains with voltage selector switch
to settings not suitable for operation
at 230 VAC.
No voltage selector.
N/A
4 Tropical
condition test
All appliances (with tropical test
requirements in applicable
Standards) shall comply with the
tropical condition test as stated in
the relevant IEC Standards.
requirements in applicable
Standards) shall comply with the
tropical condition test as stated in
the relevant IEC Standards.
Comply
P
Page 2 of 5
Report No.: 163977
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
5 Class
I
appliances
(3-pin mains
plug)
plug)
All Class I appliances must be fitted
with 3-pin mains plugs complied
with SS 145/SS 472 that are
registered with the Safety Authority.
with 3-pin mains plugs complied
with SS 145/SS 472 that are
registered with the Safety Authority.
Class II apparatus
N/A
6 Class
II
appliances
(mains plug)
a) All Class II appliances must be
fitted with 2-pin mains plug
(Appendix T) complied with EN
50075.
fitted with 2-pin mains plug
(Appendix T) complied with EN
50075.
b) Class II appliances that are fitted
with 3-pin mains plugs must use
plugs that are complied with SS 145
and registered with the Safety
Authority.
with 3-pin mains plugs must use
plugs that are complied with SS 145
and registered with the Safety
Authority.
Comply with SS145
P
7 Appliances
rated
≥ 3 kW or
connected to
fixed wiring
connected to
fixed wiring
Electric appliance ≥ 3 kW must be
connected to fixed wiring. All
connection to fixed wiring must be
in accordance with Code of Practice
CP5.
connected to fixed wiring. All
connection to fixed wiring must be
in accordance with Code of Practice
CP5.
3 kW
N/A
8 Detachable
power cord set
(consists of
mains plug,
mains cord and
appliance
connector
(consists of
mains plug,
mains cord and
appliance
connector
Detachable power cord set must be
listed in the test report critical
component list.
listed in the test report critical
component list.
Detachable power cord set.
Approved cord set provided.
See appended table, list of
critical components.
Approved cord set provided.
See appended table, list of
critical components.
P
9 Circuit
diagrams
Circuit diagrams must be indicated
with component’s values for
products tested to IEC 60065 and
IEC 60950.
with component’s values for
products tested to IEC 60065 and
IEC 60950.
Comply
P
10 Circuit
diagrams
of electronic
modules in
electrical
appliances
modules in
electrical
appliances
Circuit diagrams of the electronic
modules in the electrical appliances
must be provided.
modules in the electrical appliances
must be provided.
No such module in the
apparatus
apparatus
N/A
11 Controlled
goods
likely to be
treated as toy by
children
treated as toy by
children
Controlled goods, having an
enclosure, which is shaped and
decorated so that it is likely to be
treated as a toy by children, shall
not be accepted for certification and
registration.
enclosure, which is shaped and
decorated so that it is likely to be
treated as a toy by children, shall
not be accepted for certification and
registration.
Apparatus is not likely to be
treated as a toy by children.
treated as a toy by children.
N/A