Page 10 of 11
 
Report No.: 163977
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
5.4.1 
Norway and Sweden  
To the end of 5.4.1 (after the compliance statement) the 
following is added:  
The screen of the cable distribution system is normally 
not earthed at the entrance of the building and there is 
normally no equipotential bonding system within the 
building. Therefore the protective earthing of the building 
installation need to be isolated from the screen of a 
cable distribution system.  
It is however accepted to provide the insulation external 
to the equipment by an adapter or an interconnection 
cable with galvanic isolator, which may be provided by 
e.g. a retailer.  
The user manual shall then have the following or similar 
information in Norwegian and Swedish language 
respectively, depending on in what country the 
equipment is intended to be used in:  
“Equipment connected to the protective earthing of the 
building installation through the mains connection or 
through other equipment with a connection to protective 
earthing – and to a cable distribution system using 
coaxial cable, may in some circumstances create a fire 
hazard. Connection to a cable distribution system has 
therefore to be provided through a device providing 
electrical isolation below a certain frequency range 
(galvanic isolator, see EN 60728-11)”  
NOTE In Norway, due to regulation for installations of 
cable distribution systems, and in Sweden, a galvanic 
isolator shall provide electrical insulation below 5 MHz. 
The insulation shall withstand a dielectric strength of 1,5 
kV r.m.s., 50 Hz or 60 Hz, for 1 min.  
Translation to Norwegian (the Swedish text will also be 
accepted in Norway):  
“Utstyr som er koplet til beskyttelsesjord via nettplugg 
og/eller via annet jordtilkoplet utstyr – og er tilkoplet et 
kabel-TV nett, kan forårsake brannfare. For å unngå 
dette skal det ved tilkopling av utstyret til kabel-TV nettet 
installeres en galvanisk isolator mellom utstyret og 
kabel-TV nettet.”  
Translation to Swedish:  
”Utrustning som är kopplad till skyddsjord via jordat 
vägguttag och/eller via annan utrustning och samtidigt är 
kopplad till kabel-TV nät kan i vissa fall medfőra risk főr 
brand.  
Főr att undvika detta skall vid anslutning av utrustningen 
till kabel-TV nät galvanisk isolator finnas mellan 
utrustningen och kabel-TV nätet.” 
Class II apparatus 
N/A 
 
Page 11 of 11
 
Report No.: 163977
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
15.1.1 Denmark 
 
The text of the Danish SNC in EN 60065:2002 has 
been modified as follows:  
To the first paragraph the following is added:  
In Denmark, supply cords of single-phase appliances 
having a rated current not exceeding 13 A shall be 
provided with a plug according to the Heavy Current 
Regulations Section 107-2-D1.  
Appliances of CLASS I provided with socket-outlets 
with earth contact or which are intended to be used in 
locations where protection against indirect contact is 
required according to the wiring rules shall be 
provided with a plug in accordance with the Heavy 
Current Regulations, Section 107-2-D1 standard 
sheet DK 2-1a.  
To the second paragraph the following is added:  
Socket outlets intended for providing power to CLASS 
II apparatus with a rated current of 2,5 A shall be in 
accordance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DKA 1-4a.  
Other current ratings socket outlets shall be in 
compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DKA 1-3a or DKA 
1-3b.  
To the third paragraph the following is added:  
Mains socket-outlets with earthing contact shall be in 
compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a 
or DK 1-7a.  
Justification: Heavy Current Regulations, Section 
107-2-D1 
No socket-outlet.
 
N/A 
 
 
Page 1 of 5
 
Report No.: 163977
 
 
 
 
 
 
 
ATTACHMENT 4 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
ANNEX TO TEST REPORTS 
REGULATORY REQUIREMENTS FOR SINGAPORE 
Annex Form No. .............................. :  SG_RR_A 
Annex Form Originator ..................... :  TÜV SÜD PSB Pte Ltd 
Master Annex Form .......................... :  2008-03 
Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment 
(IECEE), Geneva, Switzerland. All rights reserved. 
 
No Items 
Requirements 
Result - Remark 
Verdict 
The following is the national differences in accordance with safety authority website 
www.spring.gov.sg/safety, ref. Singapore Consumer Protection (Safety Requirements) – Information 
Booklet – Chapter 7. 
7 SAFETY AUTHORITY’S REQUIREMENTS 
The Safety Authority monitors the safety of the controlled goods sold in Singapore by investigating 
all complaints, incidents and accidents reported to the authority. Experiences gained are translated 
into the Safety Authority’s Requirements. These requirements are to be fulfilled in addition to the 
applicable safety standards. 
No Items 
Requirements 
Result - Remark 
Verdict 
Applicable to all products 
Test certificate / 
Test report 
Test certificate / Test report more  
than three (3) years old shall be  
rejected. 
Noted
 
 
Applicable to all electrical products 
2 All 
appliances 
All appliances must be tested to 230 
VAC. 
230 Vac covered.  
3 Voltage 
selector 
(voltage mis-
match test) 
Appliance fitted with voltage 
selector shall be tested as follows: 
Connect appliance to 230 VAC 
mains with voltage selector switch 
to settings not suitable for operation 
at 230 VAC. 
No voltage selector. 
N/A 
4 Tropical 
condition test 
All appliances (with tropical test 
requirements in applicable 
Standards) shall comply with the 
tropical condition test as stated in 
the relevant IEC Standards. 
Comply
 
 
Page 2 of 5
 
Report No.: 163977
 
 
 
 
 
 
 
ATTACHMENT 4 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
5 Class 
appliances 
(3-pin mains 
plug) 
All Class I appliances must be fitted 
with 3-pin mains plugs complied 
with SS 145/SS 472 that are 
registered with the Safety Authority.
Class II apparatus 
N/A 
6 Class 
II 
appliances 
(mains plug) 
a) All Class II appliances must be 
fitted with 2-pin mains plug 
(Appendix T) complied with EN 
50075. 
b) Class II appliances that are fitted 
with 3-pin mains plugs must use 
plugs that are complied with SS 145 
and registered with the Safety 
Authority. 
Comply with SS145 
7 Appliances 
rated 
≥ 3 kW or 
connected to 
fixed wiring 
Electric appliance ≥ 3 kW must be 
connected to fixed wiring. All 
connection to fixed wiring must be 
in accordance with Code of Practice 
CP5. 
 3 kW 
N/A 
8 Detachable 
power cord set 
(consists of 
mains plug, 
mains cord and 
appliance 
connector 
Detachable power cord set must be 
listed in the test report critical 
component list. 
Detachable power cord set. 
 
Approved cord set provided. 
See appended table, list of 
critical components. 
9 Circuit 
diagrams 
Circuit diagrams must be indicated 
with component’s values for 
products tested to IEC 60065 and 
IEC 60950. 
Comply 
10 Circuit 
diagrams 
of electronic 
modules in 
electrical 
appliances 
Circuit diagrams of the electronic 
modules in the electrical appliances 
must be provided. 
No such module in the 
apparatus 
N/A 
11 Controlled 
goods 
likely to be 
treated as toy by 
children 
Controlled goods, having an 
enclosure, which is shaped and 
decorated so that it is likely to be 
treated as a toy by children, shall 
not be accepted for certification and 
registration. 
Apparatus is not likely to be 
treated as a toy by children. 
N/A 