Harman Kardon AVR 265 EMC - CB Certificate ▷ View online
Page 4 of 4
Report No.: 163977
ATTACHMENT 2
Photos
TRF No. IEC60065J
Page 1 of 10
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
ATTACHMENT TO TEST REPORT IEC 60065
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus – Safety requirements
Differences according .................... :
EN 60065:2002 + A1:2006
Attachment Form No. ..................... : EU_GD_IEC60065I
Attachment Form Originator ............. : Intertek Semko AB
Master Attachment Form .................. : 2008-05
Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
Attachment Form Originator ............. : Intertek Semko AB
Master Attachment Form .................. : 2008-05
Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
IEC 60065, GROUP DIFFERENCES (CENELEC common modifications (EN))
Clause
Requirement + Test
Result - Remark
Verdict
Contents
Add the following annexes:
Annex ZA (normative) Other international publications quoted in this standard with
the references of the relevant European publications (See the CB Bulletin)
the references of the relevant European publications (See the CB Bulletin)
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
P
3.1
Add the following indent at the end of the list
-
Exposure to excessive sound pressures from
headphones or earphones
headphones or earphones
NOTE A new method of measurement is described in
EN 50332-1, Sound system equipment: Headphones
and earphones associated
with portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 1: General
method for ”one package equipment”, and in EN 50332-
2, Sound system equipment: Headphones and
earphones associated with
portable audio equipment – Maximum sound pressure
level measurement methodology and limit
considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.
EN 50332-1, Sound system equipment: Headphones
and earphones associated
with portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 1: General
method for ”one package equipment”, and in EN 50332-
2, Sound system equipment: Headphones and
earphones associated with
portable audio equipment – Maximum sound pressure
level measurement methodology and limit
considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.
No portable audio equipment
N/A
4.1.1
Replace the text of the note by:
NOTE For ROUTINE TEST reference is made to
EN 0333
EN 0333
.
Considered.
P
5.1.i)
Add the following note:
NOTE For RATED POWER CONSUMPTION
easurements of TVs reference is made to EN 60107.
easurements of TVs reference is made to EN 60107.
Not a TV product
N/A
Page 2 of 10
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
6.1
Replace the entire subclause by:
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under the
following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE Soldered joints and paint lockings are
examples of adequate locking.
The amount of ionizing radiation is regulated by
European Council Directive 96/29/Euratom of 13
May 1996. This directive requires that at any point
10 cm from the outer surface of the apparatus, the
dose-rate shall not exceed 1µSv/h (0.1 Mr/h) taking
account of the background level.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is maintained
for 1 h, at the end of which the measurement is
made.
A picture is considered to be intelligible if the
following conditions are met:
- a scanning amplitude of at least 70% of the usable
screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least 1.5
MHz in the centre, with a similar vertical
degradation;
- not more than over flashover per 5 min.
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under the
following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE Soldered joints and paint lockings are
examples of adequate locking.
The amount of ionizing radiation is regulated by
European Council Directive 96/29/Euratom of 13
May 1996. This directive requires that at any point
10 cm from the outer surface of the apparatus, the
dose-rate shall not exceed 1µSv/h (0.1 Mr/h) taking
account of the background level.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is maintained
for 1 h, at the end of which the measurement is
made.
A picture is considered to be intelligible if the
following conditions are met:
- a scanning amplitude of at least 70% of the usable
screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least 1.5
MHz in the centre, with a similar vertical
degradation;
- not more than over flashover per 5 min.
No ionizing radiation in the
equipment
equipment
N/A
13.3.1
Delete note 4.
N/A
14
Delete note 4 and note 5.
N/A
15.1.1
Delete notes 1 and 2.
N/A
15.2
Delete note 2.
N/A
16.1
Delete note 1.
N/A
Page 3 of 10
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
16.2
Delete the note.
N/A
20
Delete note 2.
N/A
Annex B
Replace note 1 by:
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
special national conditions apply.
No TNV circuits.
N/A
Annex G
Delete the note.
N/A
Annex J.2 Delete the notes of Table J.1.
N/A
Annex N
Add after the introduction:
For ROUTINE TEST reference is made to EN
50333.
50333.
Considered.
P
Bibliograp
hy
hy
Add the following standards:
EN 60332-1: 2000, Sound system equipment: Headphones and earphones
associated with portable audio equipment –
associated with portable audio equipment –
Maximum sound pressure level measurement methodology and limit considerations
– Part 1: General method for”one package equipment”.
– Part 1: General method for”one package equipment”.
PrEN 50332-2 (uder consideration), Sound system equipment: Headphones and
earphones associated with portable
earphones associated with portable
audio equipment – Maximum sound pressure level measurement methodology and
limit considerations – Part 2:
limit considerations – Part 2:
Guidelines to associate sets with headphones coming from different manufacturers.
Add the following notes for the standards indicated:
IEC 60130
NOTE Parts 9 and 17: 1998 are harmonized as Ens (not
modified).
IEC 60169
NOTE Partly harmonized in the EN 60169/HD 134 series (not
modified).
IEC 60173
NOTE Harmonized as HD 27 S1: 1978 (not modified).
IEC 60335-2-56
NOTE Harmonized as EN 60335-2-56: 1997 (not
modified).
IEC 60335-2-82
NOTE Harmonized as EN 60335-2-82: 2000 (not
modified).
IEC 60695
NOTE Harmonized as EN 60695 series (not modified).
IEC 61040
NOTE Harmonized as EN 61040: 1992 (not modified).
IEC 61558-2-1 NOTE Harmonized as EN 61558-2-1: 1997 (not modified).
IEC 61558-2-4 NOTE Harmonized as EN 61558-2-4: 1997 (not modified).
IEC 61558-2-6 NOTE Harmonized as EN 61558-2-6: 1997 (not modified).