Harman Kardon AVR 265 EMC - CB Certificate ▷ View online
Page 2 of 11
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
6.1
6.1
Replace the entire subclause in EN 60065:2002 and EN
60065:2002/A1:2006 by:
Ionizing radiation
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided under
normal operating conditions and under fault
conditions.
60065:2002/A1:2006 by:
Ionizing radiation
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided under
normal operating conditions and under fault
conditions.
Compliance is checked by measurement under the
following conditions:
following conditions:
In addition to the normal operating conditions, all controls
adjustable from the outside BY HAND, by any object such
as a tool or a coin, and those internal adjustments or pre-
sets which are not locked in a reliable manner, are
adjusted so as to give maximum radiation whilst
maintaining an intelligible picture for 1 h, at the end of
which the measurement is made.
adjustable from the outside BY HAND, by any object such
as a tool or a coin, and those internal adjustments or pre-
sets which are not locked in a reliable manner, are
adjusted so as to give maximum radiation whilst
maintaining an intelligible picture for 1 h, at the end of
which the measurement is made.
NOTE 1 Soldered joints and paint lockings are examples
of adequate locking.
of adequate locking.
The dose-rate is determined by means of a radiation
monitor with an effective area of 10 cm², at any point 10
cm from the outer surface of the apparatus.
monitor with an effective area of 10 cm², at any point 10
cm from the outer surface of the apparatus.
Moreover, the measurement shall be made under fault
conditions causing an increase of the high-voltage,
provided an intelligible picture is maintained for 1 h, at the
end of which the measurement is made.
conditions causing an increase of the high-voltage,
provided an intelligible picture is maintained for 1 h, at the
end of which the measurement is made.
The dose-rate shall not exceed 1μSv/h (0,1 mR/h) taking
account of the background level.
account of the background level.
NOTE 2 These values appear in Directive 96/29/Euratom
of 13th May 1996.
of 13th May 1996.
A picture is considered to be intelligible if the following
conditions are met:
conditions are met:
- a scanning amplitude of at least 70 % of the usable
screen width;
- a minimum luminance of 50 cd/m² with locked blank
raster provided by a test generator;
- a horizontal resolution corresponding to at least 1,5
MHz in the centre, with a similar vertical degradation;
- not more than one flashover per 5 min.
screen width;
- a minimum luminance of 50 cd/m² with locked blank
raster provided by a test generator;
- a horizontal resolution corresponding to at least 1,5
MHz in the centre, with a similar vertical degradation;
- not more than one flashover per 5 min.
No ionizing radiation in the
equipment.
equipment.
N/A
Page 3 of 11
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Z1
Add the following new clause after Clause 20:
Z1 Resistance to candle flame ignition
A television set shall be so designed that the likelihood of
ignition and the spread of fire caused by a candle flame is
reduced.
ignition and the spread of fire caused by a candle flame is
reduced.
NOTE 1 An apparatus with a viewing screen is not
regarded to be a television set if it is declared not to be so
by the manufacturer.
regarded to be a television set if it is declared not to be so
by the manufacturer.
This requirement does not apply to the display screen of
rear projection TV’s.
rear projection TV’s.
NOTE 2 This exemption has been allowed because this
technology is falling out of use and it is expected that
within a few years it will no longer exist. This exemption
will not be extended to other technologies.
technology is falling out of use and it is expected that
within a few years it will no longer exist. This exemption
will not be extended to other technologies.
NOTE 3 The frame around the screen is not exempted
from the requirements.
from the requirements.
Wood and WOOD-BASED MATERIAL with a thickness of
at least 6 mm is considered to fulfil the V-1 requirement
when applying CLC/TS 62441.
at least 6 mm is considered to fulfil the V-1 requirement
when applying CLC/TS 62441.
Compliance is checked according to CLC/TS 62441.
NOTE 4 The term vertical, as used in the first dash of
clause 5.2 of CLC/TS 62441, does not mean a perfectly
vertical position. It should be interpreted as any surface
that can be touched by the flame of a candle of 150 mm
height and 20mm diameter while the candle is still
touching the supporting surface. A typical candle used in
the home is assumed to be 20 mm diameter.
clause 5.2 of CLC/TS 62441, does not mean a perfectly
vertical position. It should be interpreted as any surface
that can be touched by the flame of a candle of 150 mm
height and 20mm diameter while the candle is still
touching the supporting surface. A typical candle used in
the home is assumed to be 20 mm diameter.
NOTE 5 It is expected that CLC/TS 62441 will in the
future be replaced by a standard, at which time that
standard will become applicable, subject to a vote by
National Committees at the time.
future be replaced by a standard, at which time that
standard will become applicable, subject to a vote by
National Committees at the time.
Not a TV product
N/A
Page 4 of 11
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex ZA
Replace the entire Annex ZA by the following.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any
amendments) applies.
document. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any
amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
the relevant EN/HD applies.
P
Page 5 of 11
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex ZA
Cont.
P