Harman Kardon AVR 265 EMC - CB Certificate ▷ View online
Page 4 of 10
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex ZA
(normativ
e)
e)
Other international publications quoted in this standard with the references of
the relevant European publications
This European Standard incorporates by dated or undated reference, provisions
from other publications. These normative references are cited at the appropriate
places in the text and the publications are listed hereafter. For dated references,
subsequent amendments to or revisions of any of these publications apply to this
European Standard only when incorporated in it by amendment or revision. For
undated references the latest edition of the publication referred to applies (including
amendments).
NOTE When an international standard has been modified by common modification,
indicated by (mod), the relevant EN/HD applies.
the relevant European publications
This European Standard incorporates by dated or undated reference, provisions
from other publications. These normative references are cited at the appropriate
places in the text and the publications are listed hereafter. For dated references,
subsequent amendments to or revisions of any of these publications apply to this
European Standard only when incorporated in it by amendment or revision. For
undated references the latest edition of the publication referred to applies (including
amendments).
NOTE When an international standard has been modified by common modification,
indicated by (mod), the relevant EN/HD applies.
P
Page 5 of 10
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex ZA
Cont.
P
Page 6 of 10
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex ZA
Cont.
P
GROUP DIFFERENCES FOR AMENDMENT 1
COMMON MODIFICATIONS
COMMON MODIFICATIONS
-
5.1 i)
in EN 60065:2002
Replace the note by:
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is
made to EN 62087. Measurements are done in the ON (play) operating mode.
Replace the note by:
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is
made to EN 62087. Measurements are done in the ON (play) operating mode.
N/A
5.4.1
Add the following indent:
za) A warning that excessive sound pressure from earphones and headphones
can cause hearing loss.
za) A warning that excessive sound pressure from earphones and headphones
can cause hearing loss.
N/A
6.1
6.1
6.1
in EN 60065:2002
Replace the subclause by:
Ionizing radiation
Equipment that might produce ionizing radiation is checked by measuring the amount of
radiation.
The amount of radiation is determined by means of a radiation monitor of the ionizing
chamber type with an effective area of 1 000 mm2 or by measuring equipment of other
types giving equivalent results.
Measurements are made with the equipment on test operating at the most
unfavourable supply voltage (see 4.2) and with operator controls and service controls
adjusted so as to give maximum radiation whilst maintaining the equipment operative
for normal use.
Internal preset controls not intended to be adjusted during the lifetime of the equipment
are not considered to be service controls.
At any point 100 mm from the surface of the operator access area, the dose-rate shall
not exceed 1 μSv/h (0,1 mR/h) (see Note). Account shall be taken of the background
level.
NOTE These values appear in Directive 96/29/Euratom.
Replace the subclause by:
Ionizing radiation
Equipment that might produce ionizing radiation is checked by measuring the amount of
radiation.
The amount of radiation is determined by means of a radiation monitor of the ionizing
chamber type with an effective area of 1 000 mm2 or by measuring equipment of other
types giving equivalent results.
Measurements are made with the equipment on test operating at the most
unfavourable supply voltage (see 4.2) and with operator controls and service controls
adjusted so as to give maximum radiation whilst maintaining the equipment operative
for normal use.
Internal preset controls not intended to be adjusted during the lifetime of the equipment
are not considered to be service controls.
At any point 100 mm from the surface of the operator access area, the dose-rate shall
not exceed 1 μSv/h (0,1 mR/h) (see Note). Account shall be taken of the background
level.
NOTE These values appear in Directive 96/29/Euratom.
N/A
Page 7 of 10
Report No.: 163977
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Bibliogra
phy in
EN
60065:20
02
phy in
EN
60065:20
02
Replace the paragraph related to prEN 50332-2 by:
EN 50332-2:2003, Sound system equipment: Headphones and earphones
associated with portable audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part 2: Matching of sets with
headphones if either or both are offered separately EN 60065:2002/A1:2006 - 4 -
EN 50332-2:2003, Sound system equipment: Headphones and earphones
associated with portable audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part 2: Matching of sets with
headphones if either or both are offered separately EN 60065:2002/A1:2006 - 4 -
N/A
Bibliogra
phy in IEC
60065:200
1/A1:2005
phy in IEC
60065:200
1/A1:2005
Add the following notes for the standards indicated:
IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994
(not modified).
IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991
(not modified).
IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994
(not modified).
IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991
(not modified).
N/A
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
2.6.1
DK: The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Class II apparatus
N/A
13.3.1
NO: To the second paragraph the following is
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
Noted
N/A