Harman Kardon AVR 265 EMC - CB Certificate ▷ View online
Test Report issued under the responsibility of
www.nemko.com
This Test Report , when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory,
or by a laboratory having special agreement with Nemko.
or by a laboratory having special agreement with Nemko.
TEST REPORT
IEC 60065
Audio, video and similar electronic apparatus - Safety requirements
Report Reference No. .................... :
163977
Date of issue ..................................... : 2010-12-22
Total number of pages ...................... :
45 pages and refer to page 7.
CB/CCA Testing Laboratory Name:
Nemko Korea Co., Ltd.
Phone: (+82) 31 322 2333
Address ............................................. :
296, Osan-Ri, Mohyeon-Myeon, Cheoin-Gu,Yongin-Si,
Gyeonggi-Do, KOREA 449-852
Gyeonggi-Do, KOREA 449-852
Applicant’s name ........................... :
Anam Electronics Co., Ltd.
Address ............................................. :
645,Sungkok-Dong, Danwon-Gu, Ansan-City, Gyeonggi-Do, Korea
Test specification:
Standard ........................................... :
IEC 60065:2001 (Seventh Edition) + A1:2005
Test procedure .................................. : CB
Scheme
Non-standard test method…………..:
N/A
Test Report Form No. .................... :
IEC60065J
Test Report Form(s) Originator ...................... :
Intertek Semko AB
Master TRF ..................................................... :
2010-03
Copyright © 2010 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
scheme procedure shall be removed.
scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Page 2 of 45
Report No.: 163977
TRF No. IEC60065J
Test item description .................... :
AV Surround Receiver
Trade Mark ....................................... :
Manufacturer ..................................... :
Harman Consumer Inc.
8500 Balboa Blvd, Northridge, CA 91329, UNITED STATES
8500 Balboa Blvd, Northridge, CA 91329, UNITED STATES
Model/Type reference ....................... : AVR
265/230
Ratings .............................................. :
420W, 220-240V~ 50/60Hz, Class II
Page 4 of 45
Report No.: 163977
TRF No. IEC60065J
Summary of testing:
Instructions
(Clause 5.4)
(Clause 5.4)
Instructions/user manual is only in English.
The information shall be given in a language
acceptable to the country where the apparatus in
intended to be sold.
The information shall be given in a language
acceptable to the country where the apparatus in
intended to be sold.
Plug / External flexible cords
(Clause 15 and 16)
(Clause 15 and 16)
This test report does not cover the mains cord set
except for listed type in list of critical components.
Must be supplied with an approved cord set
suitable for the countries where the requirement
will be sold.
except for listed type in list of critical components.
Must be supplied with an approved cord set
suitable for the countries where the requirement
will be sold.
Tests performed (name of test and test clause):
5 Marking and instructions
7 Heating under normal operating conditions
8 Constructional requirements with regard to the
5 Marking and instructions
7 Heating under normal operating conditions
8 Constructional requirements with regard to the
protection against electric shock
9 Electric shock hazard under normal operating
conditions
10 Insulation requirements
11 Fault conditions
12 Mechanical strength
13 Clearances and creepage distances
15 Terminals
17 Electrical connections and mechanical fixings
19 Stability and mechanical hazards
conditions
10 Insulation requirements
11 Fault conditions
12 Mechanical strength
13 Clearances and creepage distances
15 Terminals
17 Electrical connections and mechanical fixings
19 Stability and mechanical hazards
Testing location:
Refer to page 3
Refer to page 3
Summary of compliance with National Differences:
The sample(s) tested complies with the requirements of IEC 60065:2001 (Seventh Edition) + A1:2005
and EN 60065:2002 + A1:2006 + A11:2008.
European Group Differences and National Differences for A1 and A11 are attached as appendices.
This apparatus is also covered the National Differences for Singapore , Korea and China, but National
Differences for China is not announced yet, and not attached in this test report.
and EN 60065:2002 + A1:2006 + A11:2008.
European Group Differences and National Differences for A1 and A11 are attached as appendices.
This apparatus is also covered the National Differences for Singapore , Korea and China, but National
Differences for China is not announced yet, and not attached in this test report.