Harman Kardon AVR 265 EMC - CB Certificate ▷ View online
Page 25 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N/A
16
External flexible cords
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
Approved sheathed PVC cord
provided.
See appended table, list of
critical components.
provided.
See appended table, list of
critical components.
P
Non-detachable cords for Class I have green/yellow
core for protective earth
core for protective earth
Class II apparatus
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
The cords conductors have
adequate cross-sectional area.
adequate cross-sectional area.
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
No interconnecting cables
comprising hazardous live
conductors.
comprising hazardous live
conductors.
N/A
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of
IEC 60227-2)
bending and mechanical stress (3.2 of
IEC 60227-2)
Cord complying with 16.1.
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
Cords have adequate
cross-sectional areas to avoid
temperature rise under normal
and fault conditions.
cross-sectional areas to avoid
temperature rise under normal
and fault conditions.
P
16.5
Adequate strain relief on external flexible cords
Appliance inlet applied
N/A
Not possible to push cord back into equipment
N/A
Strain relief device unlikely to damage flexible
cord
cord
N/A
For mains cords of Class I equipment, hazardous
live conductors become taut before earth conductor
live conductors become taut before earth conductor
Class II apparatus.
N/A
16.6
Apertures for external flexible cord: no risk of damage
to the cord during assembly or movement in use
to the cord during assembly or movement in use
Appliance inlet applied
N/A
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet to
IEC 60320-1
fitted with detachable cord set with appliance inlet to
IEC 60320-1
The apparatus is not a
transportable musical
instrument and amplifier
transportable musical
instrument and amplifier
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N/A
Page 26 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
17
Electrical connections and mechanical fixings
17.1
Torque test to table 20
See below.
P
- screws into metal: 5 times
(see appended table 17.1)
P
- screws into non-metallic material: 10 times
N/A
17.2
Correct introduction into female threads in non-
metallic material
metallic material
No female threads in
non-metallic materials.
non-metallic materials.
N/A
17.3
Cover fixing screws: captive
Captivity not necessary
P
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
Tested with screw with
10 times diameter.
10 times diameter.
P
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
Loosening is sufficiently
prevented.
prevented.
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
No contact pressure transmitted
through insulating material.
through insulating material.
P
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
No screw terminals.
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
No cover fixing devices
other than screws
other than screws
N/A
17.8
Fixing devices for detachable legs or stands
provided
provided
No detachable legs or stands
provided.
provided.
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
Connections comply,
checked by inspection.
checked by inspection.
P
Page 27 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
18
Mechanical strength of picture tubes and protection against the effects of
implosion
implosion
Picture tube separately approved to IEC 61965 .... : No picture tube used.
N/A
Picture tube separately approved to 18.1 .............. :
N/A
18.1
Picture tubes >16 cm intrinsically protected
N/A
Non-intrinsically protected tubes >16 cm used with
protective screen
protective screen
N/A
Protective film as part of implosion protection:
edges covered by enclosure
edges covered by enclosure
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6 samples
N/A
18.2.2
Samples subject to implosion test: 6 samples
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6 samples
ball): 6 samples
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
19
Stability and mechanical hazards
Mass of the equipment exceeding 7 kg ................. :
Weight: 11.0 kg
—
Apparatus intended to be fastened in place –
suitable instructions ................................................ :
suitable instructions ................................................ :
No
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
Tested on a plane inclined at
an angel of 10
an angel of 10
o
.
P
19.2
100 N force applied vertically downwards
100N force have no influence
on the stability.
on the stability.
P
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability
to point of least stability
< 25kg and < 1 M
N/A
19.4
Edges or corners not hazardous
There are no hazardous
edges or corners when the
apparatus is operating in
normal position.
edges or corners when the
apparatus is operating in
normal position.
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
No glass surface.
N/A
19.6
Wall or ceiling mountings adequate
No wall or ceiling mounting.
N/A
Page 28 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
20
Resistance to fire
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1
20.1
PCB is of flammability class
V-0 and exception is
made for small components.
V-0 and exception is
made for small components.
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components comply
with flammability requirements
in clause 14.
with flammability requirements
in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
No wires working at
voltages > 4kV or leaving
an internal fire enclosure.
voltages > 4kV or leaving
an internal fire enclosure.
P
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire enclosure
All PCB are of base material
with flammability category
V-0 or better (UL approved),
See list of critical components.
with flammability category
V-0 or better (UL approved),
See list of critical components.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
No voltage > 400V (peak).
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
N/A
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such components
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
Normal operating voltage
< 4 kV.
< 4 kV.
N/A
Click on the first or last page to see other AVR 265 service manuals if exist.