Harman Kardon AVR 265 EMC - CB Certificate ▷ View online
Page 21 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
Mains switch and relay
provided. Certified according
to IEC 61058-1.
provided. Certified according
to IEC 61058-1.
See appended table,
list of critical components.
list of critical components.
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
Separately approved switch
and relay.
and relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Separately approved switch
and relay.
and relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved switch
and relay.
and relay.
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
The apparatus is not provided
the socket outlet, but
measured the apparatus inrush
current through,
- Mains relay: Max. 25 A peak
- Mains switch: Max. 1 A peak
the socket outlet, but
measured the apparatus inrush
current through,
- Mains relay: Max. 25 A peak
- Mains switch: Max. 1 A peak
The max. loaded inrush current
value is:
- less than rated inrush current
rating of mains relay (100A),
- less than rated current
rating of mains switch (6A).
value is:
- less than rated inrush current
rating of mains relay (100A),
- less than rated current
rating of mains switch (6A).
P
Socket outlet current marking correct
No mains socket-outlets
N/A
14.7
Safety interlocks
No safety interlocks
N/A
Safety
interlocks
to 2.8 of IEC 60950
N/A
Page 22 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.8
Voltage setting devices and the like
No voltage setting devices
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
Low voltage DC motor for fans
P
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
Only DC supplied.
N/A
14.9.2
Not adversely affected by oil or grease etc.
The motor for fans are not
adversely affected by oil,
grease or other substances.
adversely affected by oil,
grease or other substances.
P
14.9.3
Protection against moving parts
The fans are placed inside the
unit. No access.
unit. No access.
P
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
Not such construction.
N/A
14.10 Batteries
No batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
No optocouplers
N/A
Optocouplers comply with Cl. 8
N/A
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
N/A
14.12
Surge suppression varistors
No surge suppression varistors
N/A
Comply with IEC 61051-2
N/A
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
except for earthed parts of permanently connected
apparatus
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N/A
Page 23 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
15 Terminals
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
Approved cord set and
appliance inlet provided.
See appended table, list of
critical components, and
summary of testing.
appliance inlet provided.
See appended table, list of
critical components, and
summary of testing.
P
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
the apparatus has mains socket outlets
No mains socket outlets
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
No mains socket outlets
N/A
15.1.2
Connectors for antenna, earth, audio, video or data See below.
P
No risk of insertion in mains socket-outlets
Antenna, RCA, Optical, HDMI,
RS-232, Mini jack, USB,
Phones and NETWORK
terminals used.
Banana plug type speaker
terminals also used, but they
are accepted due to below note.
RS-232, Mini jack, USB,
Phones and NETWORK
terminals used.
Banana plug type speaker
terminals also used, but they
are accepted due to below note.
Note:
Banana plug type speaker
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
Banana plug type speaker
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No sockets indicated with
the symbol.
the symbol.
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
not compatible with household mains socket-outlets
Not adaptor used.
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II apparatus.
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
at 25 A ................... :
N/A
Page 24 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
Appliance inlet provided
N/A
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N/A
15.3.2
Reliable connection of non-detachable cords
N/A
Not soldered to conductors of a printed circuit board
N/A
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A
Wire secured by additional means to the
conductor
conductor
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal prior
to soldering or held in place by additional means
to soldering or held in place by additional means
Appliance inlet provided
N/A
Clamping of conductor and insulation if not soldered
or held by screws
or held by screws
N/A
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of
the equipment
sectional area of conductors, for the rated current of
the equipment
Appliance inlet provided
N/A
15.3.6
Terminals to 15.3.3 have sizes required by table 16
Appliance inlet provided
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
Appliance inlet provided
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening when
the clamping is tightened or loosened and stress on
internal wiring is avoided
the clamping is tightened or loosened and stress on
internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N/A
Terminals located and shielded: test with 8 mm
strand
strand
N/A
15.4
Devices forming a part of the mains plug
N/A
15.4.1
No undue strain on mains socket-outlets
The apparatus is not a
device forming a part of the
mains plug.
device forming a part of the
mains plug.
N/A
Click on the first or last page to see other AVR 265 service manuals if exist.