Page 13 of 45
 
Report No.: 163977
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts  
Double insulated 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts  
Single insulation, but safely 
anchored. 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts.  
Double insulated according to 
8.9 and 10.3 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts. 
Single insulation, but safely 
anchored. 
N/A 
8.11 
Detaching of wires  
 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
Inlet connected wires  
hooked-in before soldered. 
Other primary wires connected 
with multi-contact housing. 
 Vibration 
test 
carried out  ......................................... :
See 12.12 
N/A 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s)  
Adequately fastened. 
8.14 
Adequate fastening of covers (push/pull test 50 N 
for 10 s)  
Covers adequately fastened  
with screws. 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
Wires safely anchored away 
from parts with high 
temperature 
8.16 
Only special supply equipment can be used  
Not supplied by a special 
supply apparatus. 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
No such winding wire used  
N/A 
8.18 
Endurance test as required by 8.17  
No such insulation winding is  
used. 
N/A 
8.19 
Disconnection from the mains 
See below. 
8.19.1 Disconnect 
device 
 
Appliance coupler is used as 
disconnect devices 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
No all-pole switch or circuit 
breaker. 
N/A 
8.19.2 
Mains switch ON indication  
Indicator lamp or display lit-on. 
8.20 
Switch not fitted in the mains cord  
No switch in the mains cord. 
 
Page 14 of 45
 
Report No.: 163977
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
8.21 
Bridging components comply with clause 14  
C904 capacitor, bridging  
contact gaps of the mains relay 
Certified component. 
See appended table, list of 
critical components. 
8.22 
Non-separable thin sheet material  
 
N/A 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltage exceeding 
1000V ac or 1500V dc. 
N/A 
9.1.1.1 
a) Open circuit voltages  
Mains input voltage >35 Vac, 
see below. 
— 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. :
U2: Max. 0.03Vpeak  
(Tested at 264V)  
 
Only U2 have been recorded 
due to the use of a linear 
transformer in power supply. 
 
c) Discharge not exceeding 45 μC  
No part or contact of a  
terminal with stored voltages 
between 60 V – 15 kV. 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
No part or contact of a terminal 
with stored voltages exceeding 
15 kV. 
N/A 
9.1.1.2 
Test with test finger and test probe  
No access to hazardous 
live parts 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers  
No live shafts knobs, handles 
or levers. 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin  
No access for the test pin. 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
Does not reach hazardous 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
Does not reach hazardous 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No pre-set controls. 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
See below 
N/A 
 
If C is not greater than 0,1 μF no test needed  
< 0.1uF 
 
 
Page 15 of 45
 
Report No.: 163977
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
Test with test finger result 
in no hazard. 
 
b) Test hook of fig. 4 for 10 s (20 N)  
Test with test hook result 
in no hazard. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
Tested with 100N result 
in no damaged 
9.2 
No hazard after removing a cover by hand  
No cover removable by hand 
N/A 
 
10 Insulation 
requirements 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ................................................................. :
Basic and resistance insulation; 
Min. 100MΩ after surge test 
10.2 Humidity 
treatment 
48 h or 120 h  ........................... :
Performed for 120 h at temp. 
40
 o
C and humidity 93% 
10.3 
Insulation resistance and dielectric strength 
between mains terminals  
(see appended table 10.3) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1)  
Class II apparatus 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
(see appended table 10.3) 
 
11 Fault 
conditions 
 
11.1 
No shock hazard under fault condition  
No electric shock hazard under 
fault conditions. 
11.2 
Heating under fault condition  
(see appended table 11.2) 
 
Flames extinguish within 10 seconds  
No flames 
 
No hazard from softening solder  
No softening solder 
 
Soldered terminations not used  as protective 
mechanism  
No protective mechanism. 
11.2.1 
Measurement of temperature rises  
(see appended table 11.2) 
11.2.2 
Temperature rise of accessible parts  
(see appended table 11.2) 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation  
(see appended table 11.2) 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min  
No exceeding the limits of 
Table 3. 
N/A 
 
Page 16 of 45
 
Report No.: 163977
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
a) Temperature rise of printed circuit boards (PCB) to 
20.1.3, exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm² : 
 
N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min  
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
No conductors are 
interrupted/peeled/loosened 
during fault conditions. 
N/A 
 
Class I protective earthing maintained  
Class II apparatus. 
N/A 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
(see appended table 11.2) 
11.2.5 
Temperature rise of windings  
(see appended table 11.2) 
11.2.6 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.5  
(see appended table 11.2) 
 
12 Mechanical 
strength 
 
12.1.1 
Bump test where mass >7 kg  
No damage in the sense of  
this standard. 
12.1.2 
Vibration test  
Assessed to be satisfactory 
constructed. 
12.1.3 
Impact hammer test  
No damage in the sense of  
this standard. 
 
Steel ball test  
No damage in the sense of  
this standard. 
12.1.4 
Drop test for portable apparatus where mass ≤ 7 kg 
No portable apparatus. 
N/A 
12.1.5 Thermoplastic 
enclosures stress relief test  
Tested, 70
 o
C, 7h 
12.2 
Fixing of knobs, push buttons, keys and levers  
Normal use will not impair the 
protection against electric 
shock. 
12.3 
Remote controls with hazardous live parts  
No cable connected remote 
control devices. 
N/A 
12.4 
Drawers (pull test 50 N, 10 s)  
No drawers. 
N/A 
12.5 
Antenna coaxial sockets providing isolation  
No antenna socket which 
insolate hazardous live parts 
from accessible parts 
N/A 
12.6 
Telescoping or rod antennas construction  
No telescoping or rod antenna. 
N/A 
12.6.1 
Telescoping or rod antennas securement  
 