DOWNLOAD Harman Kardon AVR 265 Service Manual ↓ Size: 3.34 MB | Pages: 84 in PDF or view online for FREE

Model
AVR 265
Pages
84
Size
3.34 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-265.pdf
Date

Harman Kardon AVR 265 EMC - CB Certificate ▷ View online

 
Page 29 of 45
 
Report No.: 163977
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
20.2 
Fire enclosure  
No fire enclosure. 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
 
N/A 
20.2.2 Internal 
fire 
enclosures with openings not exceeding 
1 mm in width and with openings for wires 
completely filled  
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 
N/A 
 
 
Page 30 of 45
 
Report No.: 163977
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
 
A.5 Marking 
and 
instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
Not intended for outdoor use 
N/A 
A.10 Insulation 
requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION 
NETWORKS 
 
 
Complies with IEC 62151 clause 1  
No TNV circuits 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard  
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
 
L. 5 
Marking and instructions 
 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
No electronic flash apparatus. 
N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 
N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
 
Page 31 of 45
 
Report No.: 163977
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in 
Table  3 , unless comply with 6.2.2.1.or 6.2.2.2 of 
IEC 60086-4  
No lithium batteries 
N/A 
L. 9 
Electric shock hazard under normal operating 
conditions 
Not flash synchroniser. 
N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 
N/A 
L.10 Insulation 
requirements 
 
N/A 
L. 10.3.2 
High frequency puls ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel 
ball impact test  
 
N/A 
L. 14 
Components 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 
N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 
N/A 
 
 
Page 32 of 45
 
Report No.: 163977
 
TRF No. IEC60065J 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by…..: 
Less than 0.50W 
— 
 
Position of the functional switch (W) ……..: 
— 
Operating conditions 
Standby mode; 50Hz 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
220 0.004  0.41  — 
230 0.004  0.45  — 
240 0.005  0.50  — 
Standby mode; 60Hz 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
220 0.003  0.38  — 
230 0.003  0.42  — 
240 0.003  0.45  — 
 
 
 
 
Measured at maximum non-clipped output with loaded 5V/0.5A through USB terminals; 50Hz 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
264 2.683 605.2 
2 x 34.3 W  (F) 
1 x 37.9 W  (C) 
2 x 36.3 W  (S) 
2 x 36.8 W  (S/B) 
Measured at maximum non-clipped output with loaded 5V/0.5A through USB terminals; 60Hz 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
264 2.672 602.7 
2 x 34.3 W  (F) 
1 x 37.9 W  (C) 
2 x 36.3 W  (S) 
2 x 36.8 W  (S/B) 
 
 
 
 
Tested condition: 1kHz input signal, connected 8 ohm loads for F, C, S, S/B channels 
 
Page of 84
Display