Harman Kardon AVR 265 EMC - CB Certificate ▷ View online
Page 29 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
20.2
Fire enclosure
No fire enclosure.
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
N/A
20.2.2 Internal
fire
enclosures with openings not exceeding
1 mm in width and with openings for wires
completely filled
completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
Page 30 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
A.5 Marking
and
instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
Not intended for outdoor use
N/A
A.10 Insulation
requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
NETWORKS
Complies with IEC 62151 clause 1
No TNV circuits
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
No electronic flash apparatus.
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
Page 31 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in
Table 3 , unless comply with 6.2.2.1.or 6.2.2.2 of
IEC 60086-4
Table 3 , unless comply with 6.2.2.1.or 6.2.2.2 of
IEC 60086-4
No lithium batteries
N/A
L. 9
Electric shock hazard under normal operating
conditions
conditions
Not flash synchroniser.
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10 Insulation
requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel
ball impact test
ball impact test
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N/A
Page 32 of 45
Report No.: 163977
TRF No. IEC60065J
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by…..:
Less than 0.50W
—
Position of the functional switch (W) ……..:
-
—
Operating conditions
Standby mode; 50Hz
Un (V)
In (A)
Pn (W)
Pout (W)
220 0.004 0.41 —
230 0.004 0.45 —
240 0.005 0.50 —
Standby mode; 60Hz
Un (V)
In (A)
Pn (W)
Pout (W)
220 0.003 0.38 —
230 0.003 0.42 —
240 0.003 0.45 —
Measured at maximum non-clipped output with loaded 5V/0.5A through USB terminals; 50Hz
Un (V)
In (A)
Pn (W)
Pout (W)
264 2.683 605.2
2 x 34.3 W (F)
1 x 37.9 W (C)
2 x 36.3 W (S)
2 x 36.8 W (S/B)
1 x 37.9 W (C)
2 x 36.3 W (S)
2 x 36.8 W (S/B)
Measured at maximum non-clipped output with loaded 5V/0.5A through USB terminals; 60Hz
Un (V)
In (A)
Pn (W)
Pout (W)
264 2.672 602.7
2 x 34.3 W (F)
1 x 37.9 W (C)
2 x 36.3 W (S)
2 x 36.8 W (S/B)
1 x 37.9 W (C)
2 x 36.3 W (S)
2 x 36.8 W (S/B)
Tested condition: 1kHz input signal, connected 8 ohm loads for F, C, S, S/B channels