Harman Kardon AVR 170 EMC - CB Certificate ▷ View online
Test Report issued under the responsibility of
www.nemko.com
This Test Report , when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory,
or by a laboratory having special agreement with Nemko.
or by a laboratory having special agreement with Nemko.
TEST REPORT
IEC 60065
Audio, video and similar electronic apparatus - Safety requirements
Report Number. .............................. : 209462
Date of issue ................................... : 2012-06-12
Total number of pages ................... : 52 pages and refer to page 4
Applicant’s name ............................ : Anam Electronics Co., Ltd.
Address ........................................... : 645,Sungkok-Dong, Danwon-Gu, Ansan-City,
Gyeonggi-Do, Korea
Test specification:
Standard .......................................... : IEC 60065:2001 (Seventh Edition) + am1:2005 + am2:2010
Test procedure ............................... : CB Scheme
Non-standard test method ............. : N/A
Test Report Form No. ..................... : IEC60065K
Test Report Form(s) Originator .................. : Intertek Semko AB
Master TRF .................................................... : Dated 2010-10
Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Page 2 of 52
Report No.: 209462
TRF No. IEC60065K
Test item description .................... : A/V Surround Receiver
Trade Mark ...................................... :
Manufacturer .................................. : Harman International Industries, Incorporated.
8500 Balboa Blvd, Northridge, CA 91329, UNITED STATES
Model/Type reference .................... : AVR 170/230, AVR 170/230C
Ratings ............................................ : 240 W, 220-240 V~, 50/60 Hz, Class II
Page 4 of 52
Report No.: 209462
TRF No. IEC60065K
List of Attachments (including a total number of pages in each attachment):
Attachment 1: Schematic Diagram / PCB layout (2 pages)
Attachment 2: Photos (3 pages)
Attachment 3: European group differences (15 pages)
Attachment 4: National deviations for Singapore (5 pages)
Attachment 1: Schematic Diagram / PCB layout (2 pages)
Attachment 2: Photos (3 pages)
Attachment 3: European group differences (15 pages)
Attachment 4: National deviations for Singapore (5 pages)
Summary of testing:
Instructions
(Clause 5.4)
(Clause 5.4)
Instructions / users manual is only in English.
The information shall be given in a language
acceptable to the country where the apparatus in
intended to be sold.
The information shall be given in a language
acceptable to the country where the apparatus in
intended to be sold.
Input / Temperature rise measurements
(Clause 7.1)
(Clause 7.1)
The apparatus has two modes in supplying voltage
from TF93 transformer for amplifier circuit. The one
is “HIGH mode” of 45 V, and the other is “LOW mode”
of 25 V, which is controlled by the IC1604 thermal
sensor IC on MAIN heat-sink. The apparatus is
always be started from “HIGH mode” first, and then
changed to “LOW mode” electrically by operation of
the IC1604 thermal sensor IC when the temperature
of the MAIN heat-sink is exceeding 70°C. Therefore,
the measured data in heating test at “HIGH mode” is
monitored highest values of temperature rise without
thermal stabilization before changing “LOW mode”.
The IC1604 thermal sensor IC is UL approved comp.
according to UL60730-1A.
from TF93 transformer for amplifier circuit. The one
is “HIGH mode” of 45 V, and the other is “LOW mode”
of 25 V, which is controlled by the IC1604 thermal
sensor IC on MAIN heat-sink. The apparatus is
always be started from “HIGH mode” first, and then
changed to “LOW mode” electrically by operation of
the IC1604 thermal sensor IC when the temperature
of the MAIN heat-sink is exceeding 70°C. Therefore,
the measured data in heating test at “HIGH mode” is
monitored highest values of temperature rise without
thermal stabilization before changing “LOW mode”.
The IC1604 thermal sensor IC is UL approved comp.
according to UL60730-1A.
Plug / External flexible cords
(Clause 15 and 16)
(Clause 15 and 16)
This test report does not cover the mains cord set.
Must be supplied with an approved cord set
suitable for the countries where the requirement
will be sold.
Must be supplied with an approved cord set
suitable for the countries where the requirement
will be sold.
Tests performed (name of test and test clause):
5 Marking and instructions
7 Heating under normal operating conditions
8 Constructional requirements with regard to the
5 Marking and instructions
7 Heating under normal operating conditions
8 Constructional requirements with regard to the
protection against electric shock
9 Electric shock hazard under normal operating
conditions
10 Insulation requirements
11 Fault conditions
12 Mechanical strength
13 Clearances and creepage distances
14 Components
17 Electrical connections and mechanical fixings
19. Stability and mechanical hazards
conditions
10 Insulation requirements
11 Fault conditions
12 Mechanical strength
13 Clearances and creepage distances
14 Components
17 Electrical connections and mechanical fixings
19. Stability and mechanical hazards
Testing location:
Refer to page 3.
Refer to page 3.
Click on the first or last page to see other AVR 170 service manuals if exist.