Harman Kardon AVR 170 EMC - CB Certificate ▷ View online
Page 9 of 52
Report No.: 209462
TRF No. IEC60065K
Name and address of factory (ies) .......................... : Factory 1:
Anam Electronics (Dongguan) Co., Ltd.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China.
Factory 2:
DongGuan LiaoBu Anam Electronics.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China.
Factory 2:
DongGuan LiaoBu Anam Electronics.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China.
General product information:
The apparatus under test is A/V Surround Receiver of insulation class II.
The apparatus has amplifier circuits (Front, Surround and Center), Tuner circuit, Several Signal I/O
terminals (Phones, RCA, OPTICAL, USB, RS-232C, NETWORK, mini jacks and HDMI) and
Speaker terminals - (See also photos).
The model, AVR 170/230 is basic model.
The model, AVR 170/230C is identical to tested basic model AVR 170/230 except for model
designation with marking drawing.
The apparatus under test is A/V Surround Receiver of insulation class II.
The apparatus has amplifier circuits (Front, Surround and Center), Tuner circuit, Several Signal I/O
terminals (Phones, RCA, OPTICAL, USB, RS-232C, NETWORK, mini jacks and HDMI) and
Speaker terminals - (See also photos).
The model, AVR 170/230 is basic model.
The model, AVR 170/230C is identical to tested basic model AVR 170/230 except for model
designation with marking drawing.
Page 10 of 52
Report No.: 209462
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
3 General
requirements
Safety class of the apparatus .................................. :
Class II apparatus.
P
4
General test conditions
4.1.4
Ventilation instructions require the use of the test
box
box
Tested in a wooden test box
according to instructions in
manual.
(Tested box condition: 30 cm
for top and other sides.)
according to instructions in
manual.
(Tested box condition: 30 cm
for top and other sides.)
P
5
Marking and instructions
Comprehensible and easily discernible
On front and rear side of
the enclosure
the enclosure
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / petroleum
sprit
sprit
P
5.1
a) Identification, maker ............................................ : Trade mark:
P
b) Model number or type reference ......................... : Model no. : AVR 170/230,
AVR 170/230C
See copy of marking plate.
See copy of marking plate.
P
c) Class II symbol if applicable ................................ : Class II symbol is applied in
according to IEC 60417-5172
P
d) Nature of supply ................................................... : a.c. symbol is applied in
according to IEC 60417-5032
P
e) Rated supply voltage ........................................... : 220-240 V~
P
f) Mains frequency if safety dependant ................... : 50/60 Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ............................................................................ :
apparatus supplied by supply apparatus for general
use ............................................................................ :
The apparatus is connection
to an a. c. mains supply.
to an a. c. mains supply.
N/A
Measured current or power consumption ............... :
N/A
Deviation
%
(max 10%) ........................................... :
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply :
us intended for connection to an a.c. mains supply :
240 W
P
Measured current or power consumption ............... : Max. 261.4 W
(see appended table 7.1)
P
Measured current or power consumption for
Television set ........................................................... :
Television set ........................................................... :
No television set.
N/A
Deviation
%
(max 10%) ........................................... : Exceeding marked value but
within deviation 10 %.
P
5.2
a) Earth terminal
Class II apparatus.
N/A
Page 11 of 52
Report No.: 209462
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
b) Hazardous live terminals
No hazardous live terminals.
The output signal will rise to
21.7 Vp at maximum out
power if the speaker load is
disconnected in the speaker
terminal, No hazard.
The output signal will rise to
21.7 Vp at maximum out
power if the speaker load is
disconnected in the speaker
terminal, No hazard.
P
c) Markings on supply output terminals
No socket outlet for providing
power to other apparatus
power to other apparatus
N/A
5.3
a) Use of triangle with exclamation mark
Correct symbol applied:
- In rear side in connection
with CAUTION of opening
- In circuit diagram.
Further, no incorrect use of
this symbol is found.
- In rear side in connection
with CAUTION of opening
- In circuit diagram.
Further, no incorrect use of
this symbol is found.
P
b) marking on loudspeaker grille, IEC 60417-5036
Not used loudspeaker grille
N/A
5.4
Instructions for use
User information in the
following language: English.
See comments in Summary
of Testing.
following language: English.
See comments in Summary
of Testing.
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
The user manual includes
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
P
b) Hazardous live terminals, instructions for wiring
No hazardous live terminals
N/A
c) Instructions for replacing lithium battery
No battery
N/A
d) Class I earth connection warning
Class II apparatus
N/A
e) Instructions for multimedia system connection
Instructions for multimedia
system connection provided
in user manual.
system connection provided
in user manual.
P
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
No such equipment
N/A
g) Warning: battery exposure to heat
No such equipment
N/A
h) Warning: protective film on CRT face
No CRT
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Appliance coupler is
disconnecting device and
readily operable.
disconnecting device and
readily operable.
P
c) Instructions for permanently connected equipment Not permanent connected
equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
Information provided in user
manual.
manual.
P
Page 12 of 52
Report No.: 209462
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
6 Hazardous
radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1:2007
.................................................................................. :
.................................................................................. :
No laser radiation
N/A
Emission limits under fault conditions ..................... :
N/A
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
No fuse links operate during
normal operating operation.
(see appended table 7.1)
normal operating operation.
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
Bobbins for transformer / Iine
filter (base) are made of
Phenolic except below
components.
See appended table 7.2 for
AC connector (wafer) CN90,
SW91.
filter (base) are made of
Phenolic except below
components.
See appended table 7.2 for
AC connector (wafer) CN90,
SW91.
P
8
Constructional requirements with regard to the protection against electric
shock
shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation “By hand” not
possible.
possible.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials used
N/A
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
No cover removable by hand.
N/A
8.5
Class I equipment
Class II equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Click on the first or last page to see other AVR 170 service manuals if exist.