Harman Kardon AVR 170 EMC - CB Certificate ▷ View online
Page 17 of 52
Report No.: 209462
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Class I protective earthing maintained
Class II equipment.
N/A
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
(see appended table 11.2)
P
12 Mechanical
strength
12.1.1
Bump test where mass >7 kg
Mass : 6.0 kg
N/A
12.1.2
Vibration test
Assessed to be
satisfactory constructed
satisfactory constructed
P
12.1.3
Impact hammer test
No damage in the sense
of this standard
of this standard
P
Steel ball test
No damage in the sense
of this standard
of this standard
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg No portable apparatus
N/A
12.1.5 Thermoplastic
enclosures stress relief test
No risk of shrinkage or
distortion on enclosure.
distortion on enclosure.
P
12.2
Fixing of knobs, push buttons, keys and levers
Normal use will not impair
the protection against
electric shock
the protection against
electric shock
P
12.3
Remote controls with hazardous live parts
No remote control containing
hazardous live parts
hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawers.
N/A
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial sockets
N/A
12.6
Telescoping or rod antennas construction
No telescoping or rod antennas
N/A
12.6.1
Telescoping or rod antennas securement
N/A
Page 18 of 52
Report No.: 209462
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3
See 13.3
P
Creepage distances in accordance with 13.4
See 13.4
P
13.2
Determination of working voltage
Conventional transformer
used. Upper rated supply
voltage (240V) applied in
determining the working
voltage.
used. Upper rated supply
voltage (240V) applied in
determining the working
voltage.
P
13.3
Clearances
2N for internal parts and
30N for enclosure are
considered when determining
clearances.
30N for enclosure are
considered when determining
clearances.
P
13.3.1 General
Considered
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ............ :
with table 8 and, where applicable, table 9 ............ :
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
No hazardous secondary
voltages
voltages
N/A
13.3.4
Measurement of transient voltages
No measurement of
transient voltages
transient voltages
N/A
13.4
Creepage distances
CTI > 100
(see appended table 13)
(see appended table 13)
P
Creepage distances greater than table 11 minimum
values
values
Not applicable
N/A
13.5
Printed boards
Refer to below
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
No such PCB used
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
No type B coated printed
circuit boards
circuit boards
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
No uncemented joints
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
500V test for transformers, magnetic coupler and
similar devices, if insulation is relied upon for safety
similar devices, if insulation is relied upon for safety
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12
not conductively connected to the mains, clearances
and creepage distances as in table 12
No such part used
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
Approved optocoupler.
See clause 8.8
See clause 8.8
P
Page 19 of 52
Report No.: 209462
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14 Components
14.1 Resistors
P
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
Bleeder resistor RX93,
connected between
Line and Neutral, located after
mains fuse, certified
component by VDE.
See appended table, list of
critical components
connected between
Line and Neutral, located after
mains fuse, certified
component by VDE.
See appended table, list of
critical components
P
Resistors
separately approved .............................. :
RX93
See appended table, list of
critical components
See appended table, list of
critical components
P
14.2
Capacitors and RC units
P
Capacitors separately approved :
Yes, see below
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ……:
CY91, CY92, CY93, CY94
and C95, certified
according to IEC 60384-14.
and C95, certified
according to IEC 60384-14.
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ……:
Capacitor CX91 and CX92
certified according to
IEC 60384-14.
certified according to
IEC 60384-14.
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
No such capacitors
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................. :
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................. :
Several E. cap. exceeding
volume 1750mm
volume 1750mm
3
, but metal
cases.
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................ :
Several E. cap. exceeding
volume 1750mm
volume 1750mm
3
, but metal
cases.
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ....................................................................... :
metal ....................................................................... :
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5.
according to 14.3.3, 14.3.4
and 14.3.5.
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
Adequate marking applied.
Manufacturer`s ID and type no.
Manufacturer`s ID and type no.
P
Transformers and inductors separately approved :
No
N/A
Page 20 of 52
Report No.: 209462
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.3.2 General
Isolating transformers
P
Insulation material complies with clause 20.1.4
Considered. The insulation
material of isolating transf.
complies with flammability
category of Table 21.
material of isolating transf.
complies with flammability
category of Table 21.
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table 13)
P
14.3.3.2 Transformers
meet
the constructional requirements (see appended table 14.3.3)
P
14.3.4
Separation between windings
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) ............................. :
between hazardous live parts and accessible parts
(double or reinforced insulation) ............................. :
Double or reinforced insulation
between pr. and sec. windings
according to clause 8.8.
(see appended table 14.3.3)
between pr. and sec. windings
according to clause 8.8.
(see appended table 14.3.3)
P
Coil formers and partition walls > 0,4 mm
> 0.4 mm.
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Transformer are evaluate
with class II construction.
with class II construction.
N/A
14.3.4.3
Separating transformers with at least basic insulation Windings of Class II
construction used.
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts
between hazardous live
windings and accessible
conductive parts
P
Coil formers and partition walls > 0,4 mm
>0.4 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Winding of Class II
construction used.
construction used.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No high-voltage components.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A