Harman Kardon AVR 170 EMC - CB Certificate ▷ View online

 
Page 13 of 52 
Report No.: 209462 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
Class II equipment 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
Double/Reinforced insulation 
complies with requirements 
specified in clause 10 and 13. 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
The apparatus have isolated  
transformer complies with  
clause 14.3. 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
No such components 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
No such capacitors. 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
No such capacitors. 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
CY91, CY92, CY93, CY94 and 
CY95 capacitors, bridging 
reinforced insulation in the 
apparatus. 
8.7 
This clause is void  
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
No such components 
N/A 
 
Reinforced insulation > 0,4 mm (mm)  .................... : 
a. Transformers bobbin. 
ref. 14.3. 
b. Optocoupler inner 
insulation, ref. 14.11 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
Insulation in TF91, TF92 and 
TF93 transformer. 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3  
Thin sheet insulation used in 
TF91, TF92 and TF93 
transformer between, 
- pri. and sec. winding, 
- pri. and iron core (ic). 
- sec. and iron core (ic). 
(see appended table 14.3.3) 
 
Page 14 of 52 
Report No.: 209462 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
Double insulated 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts 
Single insulated but safely  
anchored. 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
Double insulated according to 
8.9 and 10.3 
 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts.
Single insulated but safely  
anchored. 
N/A 
8.11 
Detaching of wires  
 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
Inlet connected wires 
hooked-in before soldered. 
Other primary wires connected 
with multi-contact housing. 
 Vibration 
test 
carried out  ........................................ :  See clause 12.1.2 
N/A 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
Adequately fastened. 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
Covers adequately fastened  
with screws. 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
Wires safely anchored away 
from parts with high 
temperature 
8.16 
Only special supply equipment can be used  
No special supply apparatus. 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
No such winding wire. 
N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
See below 
8.19.1 Disconnect 
device 
 
Appliance coupler is used as 
disconnect devices. 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
All-pole switch used but 
not used as disconnect device 
N/A 
8.19.2 
Mains switch ON indication  
LED for ON indication  
provided. 
8.20 
Switch not fitted in the mains cord  
Cord set not supplied for 
testing. 
See summary of testing. 
N/A 
8.21 
Bridging components comply with clause 14  
 
N/A 
8.22 
Non-separable thin sheet material  
 
N/A 
 
 
Page 15 of 52 
Report No.: 209462 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
P 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltages >1000 V ac or  
>1500 V dc 
N/A 
9.1.1.1 
a) Open circuit voltages  
Mains input voltage 
> 35 Vac, see below. 
 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. : 
U1: Max. 1.40 Vpeak 
U2: Max. 0.32 Vpeak 
(Tested at 264 V) 
 
c) Discharge not exceeding 45 μC  
No part or contact of a  
terminal with stored voltages 
between 60V - 15 kV. 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
No part or contact of a terminal 
with stored voltages exceeding 
15kV. 
N/A 
9.1.1.2 
Test with test finger and test probe  
No access to hazardous 
live parts 
9.1.2 
No hazardous live shafts of knobs, handles or levers  No live shafts of knobs, 
handles or levers. 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No access for the test pin. 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
Does not reach hazardous 
live parts 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
Does not reach hazardous 
live parts 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No pre-set controls 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
0 V after 2 s, 
Bleeder resistor provided. 
See clause 14.1 b), and 
appended table, list of critical 
components. 
 
If C is not greater than 0,1 μF no test needed  
> 0.1  μF 
 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
Test with test finger result 
in no hazard 
 
b) Test hook of fig. 4 for 10 s (20 N)  
Test with test hook results 
in no hazard. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
Test with test tool results 
in no hazard. 
9.2 
No hazard after removing a cover by hand  
No cover removable by hand 
N/A 
 
 
Page 16 of 52 
Report No.: 209462 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
10 Insulation 
requirements 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ................................................................. : 
Basic: >2.6 MΩ, 
Reinforced: >5.2 MΩ after 
surge test 
10.2 Humidity 
treatment 
48 h or 120 h  .......................... : 
Performed for 120 h at temp. 
40
C and humidity 93% 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table 10.3) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
Class II apparatus 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
(see appended table 10.3) 
 
11 Fault 
conditions 
 
11.1 
No shock hazard under fault condition  
No electric shock hazard  
under fault conditions. 
11.2 
Heating under fault condition  
(see appended table 11.2) 
 
Flames extinguish within 10 seconds  
No flames 
 
No hazard from softening solder  
No softening of solder 
 
Soldered terminations not used  as protective 
mechanism  
No soldered terminations 
11.2.1 
Measurement of temperature rises  
(see appended table 11.2) 
11.2.2 
Temperature rise of accessible parts  
(see appended table 11.2) 
11.2.3 
Temperature rise of parts, other than windings and 
printed boards, providing electrical insulation 
(see appended table 11.2) 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
Temperature rises are within 
the limits. 
11.2.5 
Temperature rise of windings  
(see appended table 11.2) 
11.2.6 
Temperature rise of printed boards shall not exceed 
the limits of table 3 by max. 100 K for max. 5 min 
No exceeding the limits of  
Table 3. 
N/A 
 
Printed circuit boards (PCB) classified as V-0 
according to 60695-11-10 or Clause G.1 may 
exceed the limit in table 3 in case a) and b): 
 
N/A 
 
a) Temperature rise of printed circuit boards 
exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm²  ............... :
No area where temperature 
exceeds 100K above limits 
N/A 
 
b) Temperature rise of printed circuit boards 
exceeding the limits of table 3 up to 300 K for an 
area not greater than 2 cm² for a maximum of 5 min 
No area where temperature 
exceeds 300K above limits 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
No conductors are interrupted/ 
peeled/ loosened during fault 
conditions 
N/A 
Page of 85