Harman Kardon AVR 170 EMC - CB Certificate ▷ View online
Page 21 of 52
Report No.: 209462
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.5 Protective
devices
P
Protective devices used within their ratings
Certified fuse used.
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Certified fuse used.
See appended table,
list of critical components.
See appended table,
list of critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved
TS91 and TS92 approved
component according to
IEC 60730-1.
See appended table, list of
critical components.
component according to
IEC 60730-1.
See appended table, list of
critical components.
P
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
No thermal links
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No soldering.
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuse are approved component
according to IEC 60127.
See appended table, list of
critical components.
according to IEC 60127.
See appended table, list of
critical components.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
The following marking applied;
F901: T6.3A H 250V
F901: T6.3A H 250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
No fuses holder so designed
that fuse-links can be
connected in parallel.
that fuse-links can be
connected in parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC thermistors comply with IEC 60730-1:2007
.
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
Only standard fuse used.
N/A
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058-1 including:
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
Mains switch used
Certified by FIMKO
See appended table, list of
critical components
Certified by FIMKO
See appended table, list of
critical components
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
N/A
Page 22 of 52
Report No.: 209462
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
additional tests to IEC 61058-1
The measured inrush current
through mains switch is
22.2 A.
The measured inrush current
value is less than rated inrush
rating of the mains switch
(rated 100A).
through mains switch is
22.2 A.
The measured inrush current
value is less than rated inrush
rating of the mains switch
(rated 100A).
P
Socket outlet current marking correct
No mains socket outlet.
N/A
14.7
Safety interlocks
No safety interlocks.
N/A
Safety interlocks to 2.8 of IEC 60950-1
N/A
14.8
Voltage setting devices and the like
No voltage setting devices.
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
No motors
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
P
14.9.3
Protection against moving parts
P
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
N/A
14.10 Batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
No batteries.
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within manufacturers
limits
limits
N/A
Page 23 of 52
Report No.: 209462
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
Approved
optocoupler.
Internal/external creepage
and clearance distances are
> 4 mm / >5 mm.
See appended table, list of
critical components.
and clearance distances are
> 4 mm / >5 mm.
See appended table, list of
critical components.
P
a) Comply with 13.6 (jointed insulation) and N.2.1
N/A
b) Comply with IEC 60747-5-5:2007
N/A
Alternative to a) and b) optocoupler comply with 13.8
N/A
a) Comply with 13.6 (jointed insulation) and N.2.1
N/A
14.12
Surge suppression varistors
P
Comply with IEC 61051-2
Comply with IEC 61051-2.
VT91 and VT92
VT91 and VT92
P
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
except for earthed parts of permanently connected
apparatus
No such application
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
A certified varistor used.
P
Page 24 of 52
Report No.: 209462
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
15 Terminals
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard
and mains socket-outlet meet the appropriate
standard
Approved appliance inlet
provided.
provided.
See appended table, list of
critical components
critical components
P
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
the apparatus has mains socket outlets
No mains socket-outlets
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
No mains socket-outlets
N/A
15.1.2
Connectors for antenna, earth, audio, video or
data
data
P
No risk of insertion in mains socket-outlets
Only RCA, Antenna, Optical,
Network, RS232C, mini jacks
and HDMI terminal used.
Banana plug type speaker
terminal also used, but they
are accepted due to below
note.
Network, RS232C, mini jacks
and HDMI terminal used.
Banana plug type speaker
terminal also used, but they
are accepted due to below
note.
Note) Banana type speaker
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
P
No risk of insertion into audio- or video- outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No sockets indicated with
the symbol
the symbol
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
not compatible with household mains socket-outlets
Not adaptors used
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II apparatus.
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord provided
with separate protective earth terminal near mains
input
with separate protective earth terminal near mains
input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
at 25 A ................... :
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
P
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
Appliance inlet applied
N/A