Harman Kardon AVR 151 (serv.man5) EMC - CB Certificate ▷ View online
Page 2 of 5
Report No.: 232173
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
6 Class
I
appliances
(3-pin mains
plug)
(3-pin mains
plug)
All Class I appliances must be fitted
with 3-pin mains plugs complied with
SS 145/SS 472 that are registered
with the Safety Authority.
with 3-pin mains plugs complied with
SS 145/SS 472 that are registered
with the Safety Authority.
Class II apparatus
N/A
7 Class
II
appliances
(mains plug)
(mains plug)
a) All Class II appliances must be
fitted with 2-pin mains plug (Appendix
T) complied with EN 50075.
b) Class II appliances that are fitted
with 3-pin mains plugs must use
plugs that are complied with SS 145
and registered with the Safety
Authority.
fitted with 2-pin mains plug (Appendix
T) complied with EN 50075.
b) Class II appliances that are fitted
with 3-pin mains plugs must use
plugs that are complied with SS 145
and registered with the Safety
Authority.
See appended table, list of
critical components, and
comments in Summary
of Testing.
critical components, and
comments in Summary
of Testing.
P
8 Appliances
rated ≥ 3 kW or
connected to
fixed wiring
connected to
fixed wiring
Electric appliance ≥ 3 kW must be
connected to fixed wiring. All
connection to fixed wiring must be in
accordance with Code of Practice
CP5.
connected to fixed wiring. All
connection to fixed wiring must be in
accordance with Code of Practice
CP5.
Not exceed 3kW
N/A
9 Detachable
power cord set
(consists of
mains plug,
mains cord and
appliance
connector
(consists of
mains plug,
mains cord and
appliance
connector
Detachable power cord set must be
listed in the test report critical
component list.
listed in the test report critical
component list.
See appended table, list of
critical components, and
comments in Summary
of Testing.
critical components, and
comments in Summary
of Testing.
P
10 Circuit
diagrams
Circuit diagrams must be indicated
with component’s values for
products tested to IEC 60065 and
IEC 60950.
with component’s values for
products tested to IEC 60065 and
IEC 60950.
Comply
P
11 Circuit
diagrams of
electronic
modules in
electrical
appliances
electronic
modules in
electrical
appliances
Circuit diagrams of the electronic
modules in the electrical appliances
must be provided.
modules in the electrical appliances
must be provided.
No such module in the
apparatus
apparatus
N/A
12 Controlled
goods likely to
be treated as
toy by children
be treated as
toy by children
Controlled goods, having an
enclosure, which is shaped and
decorated so that it is likely to be
treated as a toy by children, shall not
be accepted for certification and
registration.
enclosure, which is shaped and
decorated so that it is likely to be
treated as a toy by children, shall not
be accepted for certification and
registration.
Apparatus is not likely to be
treated as a toy by children.
treated as a toy by children.
N/A
Page 3 of 5
Report No.: 232173
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Applicable to electric airport
13 Reboil
Switch
No part of the reboil switch is
allowed to protrude into the water
pot, even if it is located above the
maximum water level mark.
allowed to protrude into the water
pot, even if it is located above the
maximum water level mark.
No Reboil switch
N/A
Applicable to AC adaptor
14 3-pin
AC
adaptor
(Appendix V)
(Appendix V)
Test report showing that the 3-pin
complied with sub-clauses 12.1 &
12.3 of SS 246 must be submitted.
complied with sub-clauses 12.1 &
12.3 of SS 246 must be submitted.
No AC adaptor
N/A
15 2-pin
AC
adaptor
(Appendix V)
(Appendix V)
The 2-pin (Appendix T) shall comply
with EN 50075.
with EN 50075.
N/A
16 Detachable
power supply
cord set not
supplied by
Registered
Supplier
cord set not
supplied by
Registered
Supplier
Registered Supplier who is not
supplying the detachable power
supply cord set together with the AC
Adaptor must provide written
instruction to its customer on the type
of approved detachable power cord
set to use.
supplying the detachable power
supply cord set together with the AC
Adaptor must provide written
instruction to its customer on the type
of approved detachable power cord
set to use.
N/A
Applicable to computer products
17 CD/DVD
ROM
(used in
personal
computer)
personal
computer)
Test certificate showing that CD/DVD
ROM has complied with IEC 825
must be provided.
ROM has complied with IEC 825
must be provided.
No CD and DVD ROM
N/A
18 Modem
Card
(used in
personal
computer)
personal
computer)
Modem card incorporated in the
personal computer must be tested at
set level (sub-clauses 5.1 & 6 of IEC
60950) or at component level.
personal computer must be tested at
set level (sub-clauses 5.1 & 6 of IEC
60950) or at component level.
No modem card
N/A
Applicable to ceiling fan and cycle fan
19
Ceiling fan and
cycle fan
cycle fan
a) These appliances must be tested
to sub-clauses 5.7 and 5.8 of SS 360:
1992.
b) Installation instruction must
mention the 3 expansion bolts for
fastening the main suspension, safety
cord, expansion bolt with hook for
fastening safety cord and mounting
plate. (Appendix Q)
c) Drawing (Appendix P) to show that
the wires within the motor shaft are
not stressed must be provided.
to sub-clauses 5.7 and 5.8 of SS 360:
1992.
b) Installation instruction must
mention the 3 expansion bolts for
fastening the main suspension, safety
cord, expansion bolt with hook for
fastening safety cord and mounting
plate. (Appendix Q)
c) Drawing (Appendix P) to show that
the wires within the motor shaft are
not stressed must be provided.
No ceiling fan and cycle fan
N/A
Page 4 of 5
Report No.: 232173
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Applicable to portable/wall socket-outlet and portable cable reel
20 Portable/wall
socket-outlet
and portable
cable reel
and portable
cable reel
a) If residual current device (RCD) is
incorporated, its tripping current must
be less than 30mA and operating
time must be less than 0.1 second
and testing to sub-clauses 9.9.2.1,
9.9.2.2, 9.9.2.3 and 9.16 of SS 97:
Part 1: 2000 are required.
b) The shutters screening the current-
carrying socket contacts shall not be
opened by the insertion of any
corresponding SINGLE pin of the
plug into any current-carrying socket
aperture.
incorporated, its tripping current must
be less than 30mA and operating
time must be less than 0.1 second
and testing to sub-clauses 9.9.2.1,
9.9.2.2, 9.9.2.3 and 9.16 of SS 97:
Part 1: 2000 are required.
b) The shutters screening the current-
carrying socket contacts shall not be
opened by the insertion of any
corresponding SINGLE pin of the
plug into any current-carrying socket
aperture.
No portable/wall socket-
outlet and portable cable
reel.
outlet and portable cable
reel.
N/A
21
Wall switched
socket-outlet
(2 x single
socket-outlet)
socket-outlet
(2 x single
socket-outlet)
Single socket-outlet with 2-gang
faceplate/frame must be fulfilled
with the test requirements as 2-gang
socket-outlet.
faceplate/frame must be fulfilled
with the test requirements as 2-gang
socket-outlet.
N/A
22
Remote
controlled
portable/wall
portable
socket-outlet
controlled
portable/wall
portable
socket-outlet
Remote controlled portable/wall
socket-outlet shall not be
allowed for registration.
socket-outlet shall not be
allowed for registration.
N/A
Applicable to roaster
23
Roaster
A metal ring (Appendix U) must be
provided to prevent the roaster from
falling off in case the glass bowl
shattered.
provided to prevent the roaster from
falling off in case the glass bowl
shattered.
No roaster
N/A
Applicable to Residual Current Circuit Breaker (RCCB)
33 RCCB
Registration of RCCB is limited to 30
mA sensitivity and the operating time
must be less than 0.1 second.
Electronic RCCB will not be accepted
for registration.
mA sensitivity and the operating time
must be less than 0.1 second.
Electronic RCCB will not be accepted
for registration.
No residual current circuit
breaker
breaker
N/A
Applicable to electric instantaneous and storage water heater
34
Instantaneous
electric water
heater and mains
pressure electric
storage water
heater
electric water
heater and mains
pressure electric
storage water
heater
Heating elements used must not
be of the "bare-element" type.
be of the "bare-element" type.
No electric instantaneous
and storage water heater
and storage water heater
N/A
Page 5 of 5
Report No.: 232173
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
35
Water heater
incorporated with
residual current
device(RCD)
incorporated with
residual current
device(RCD)
Testing to sub-clauses 9.9.2.1,
9.9.2.2, 9.9.2.3 and 9.16 of SS 97:
Part 1: 2000 are required.
9.9.2.2, 9.9.2.3 and 9.16 of SS 97:
Part 1: 2000 are required.
N/A
Applicable to multiway adaptor
36 Multiway
adaptor
with 3-pin socket-
outlets or
combination of 3-
pin and 2-pin
socket-outlets
outlets or
combination of 3-
pin and 2-pin
socket-outlets
a) The socket contacts of the
adaptor shall only accept 13A 3-pin
mains plug complying with SS 145
and/or 2.5A 2-pin mains plug
complying with EN 50075.
b) The shutters screening the
current-carrying socket contacts
shall not be opened by the
insertion of any corresponding
SINGLE pin of the plug into any
current-carrying socket aperture.
c) A barrier or other acceptable
means shall be provided on the
engagement surface of the 2.5A 2-
pin socket-outlet of the adaptor to
PREVENT entry of any types of 2-
pin mains plugs except those
complying with EN 50075. (note:
shutters cannot be regarded as
barriers)
d) Adaptor incorporates with switch
would require additional test to
sub-clauses 13.11, 17.1.3 and
18.1.3 of SS 145: Part 2: 1997.
adaptor shall only accept 13A 3-pin
mains plug complying with SS 145
and/or 2.5A 2-pin mains plug
complying with EN 50075.
b) The shutters screening the
current-carrying socket contacts
shall not be opened by the
insertion of any corresponding
SINGLE pin of the plug into any
current-carrying socket aperture.
c) A barrier or other acceptable
means shall be provided on the
engagement surface of the 2.5A 2-
pin socket-outlet of the adaptor to
PREVENT entry of any types of 2-
pin mains plugs except those
complying with EN 50075. (note:
shutters cannot be regarded as
barriers)
d) Adaptor incorporates with switch
would require additional test to
sub-clauses 13.11, 17.1.3 and
18.1.3 of SS 145: Part 2: 1997.
No multiway adaptor
N/A
Applicable to plasma/LCD display monitor
37 Plasma/LCD
display monitor
with TV tuner
with TV tuner
Plasma/LCD display monitor tested
to IEC 60950 would require
additional test to clauses 9 (related
to antenna only), 10.1, 10.2, 10.3
and 12.5 of IEC 60065.
to IEC 60950 would require
additional test to clauses 9 (related
to antenna only), 10.1, 10.2, 10.3
and 12.5 of IEC 60065.
No Plasma/LCD display
monitor
monitor
N/A
Click on the first or last page to see other AVR 151 (serv.man5) service manuals if exist.