Harman Kardon AVR 151 (serv.man5) EMC - CB Certificate ▷ View online
Page 14 of 16
Report No.: 232173
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
13.3.1
NO: To the second paragraph the following is
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
Noted.
N/A
15.1.1
(A11:2008)
(A11:2008)
Denmark
The text of the Danish SNC in EN 60065:2002 has
been modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with the
Heavy Current Regulations, Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet DKA
1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA
1-3b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a
or DK 1-7a.
Justification: Heavy Current Regulations, Section
107-2-D1
The text of the Danish SNC in EN 60065:2002 has
been modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with the
Heavy Current Regulations, Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet DKA
1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA
1-3b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a
or DK 1-7a.
Justification: Heavy Current Regulations, Section
107-2-D1
No socket-outlets.
Plug with supply cord for DK
not provided.
See summary of testing.
Plug with supply cord for DK
not provided.
See summary of testing.
N/A
15.1.1
IE: Apparatus which is fitted with a flexible cable or
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
Justification: SI 525: 1997
Not provided.
See summary of testing.
See summary of testing.
N/A
Page 15 of 16
Report No.: 232173
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
15.1.1
NO: Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as a applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as a applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
§ 24 Mechanical strength
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall be
tested
Justification: Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall be
tested
Justification: Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
No mains socket-outlets
N/A
15.1.1
UK: Apparatus which is fitted with a flexible cable
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification: SI 1768: 1994
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification: SI 1768: 1994
Considered.
See appended table, list of
critical components.
See appended table, list of
critical components.
P
Page 16 of 16
Report No.: 232173
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
J.2
NO: After Table J.1 the following is added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
Noted.
—
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN)
5.1
IT: Additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
No TV receiver
N/A
IT:User instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: Certification number on the back cover
N/A
6.1
DE: The following requirement applies:
For the operation of any cathode ray tube intended
for the display of visual images operating at an
acceleration voltage exceeding 40 kV, authorization
is required, or application of type approval
(Bauartzulassung) and marking.
Justification: German ministerial decree against
ionizing radiation (Röntgenverordnung), in force
since 2002-07-01, implementing the European
Directive 96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt,
Bundesallee 100, D-38116 Braunschweig, Tel.:
Int+49-531-592-6320, Internet: http://www.ptb.de
For the operation of any cathode ray tube intended
for the display of visual images operating at an
acceleration voltage exceeding 40 kV, authorization
is required, or application of type approval
(Bauartzulassung) and marking.
Justification: German ministerial decree against
ionizing radiation (Röntgenverordnung), in force
since 2002-07-01, implementing the European
Directive 96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt,
Bundesallee 100, D-38116 Braunschweig, Tel.:
Int+49-531-592-6320, Internet: http://www.ptb.de
No CRT Used in the
equipment.
equipment.
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
No such switches
N/A
Page 1 of 5
Report No.: 232173
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
ANNEX TO TEST REPORTS
REGULATORY REQUIREMENTS FOR SINGAPORE
Annex Form No. .............................. : SG_RR_A
Annex Form Originator ..................... : TÜV SÜD PSB Pte Ltd
Master Annex Form .......................... : 2008-03
Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
(IECEE), Geneva, Switzerland. All rights reserved.
No
Items
Requirements
Result - Remark
Verdict
The following is the national differences in accordance with safety authority website
www.spring.gov.sg/safety, ref. Singapore Consumer Protection (Safety Requirements) – Information
Booklet – Chapter 7.
www.spring.gov.sg/safety, ref. Singapore Consumer Protection (Safety Requirements) – Information
Booklet – Chapter 7.
7 SAFETY AUTHORITY’S REQUIREMENTS
The Safety Authority monitors the safety of the controlled goods sold in Singapore by
investigating all complaints, incidents and accidents reported to the authority. Experiences gained
are translated into the Safety Authority’s Requirements. These requirements are to be fulfilled in
addition to the applicable safety standards.
The Safety Authority monitors the safety of the controlled goods sold in Singapore by
investigating all complaints, incidents and accidents reported to the authority. Experiences gained
are translated into the Safety Authority’s Requirements. These requirements are to be fulfilled in
addition to the applicable safety standards.
No
Items
Requirements
Result - Remark
Verdict
Applicable to all products
1 Test
certificate
/ Test report
Test certificate / Test report more
than three (3) years old shall be
rejected.
than three (3) years old shall be
rejected.
Noted
—
2
Controlled
Goods
incorporated
with additional
function
Goods
incorporated
with additional
function
The additional function must be
tested to its applicable safety
standard.
tested to its applicable safety
standard.
N/A
Applicable to all electrical products
3 All
appliances
All appliances must be tested to 230
VAC.
VAC.
Covered.230 Vac.
P
4 Voltage
selector
(voltage mis-
match test)
(voltage mis-
match test)
Appliance fitted with voltage selector
shall be tested as follows:
Connect appliance to 230 VAC mains
with voltage selector switch to
settings not suitable for operation at
230 VAC.
shall be tested as follows:
Connect appliance to 230 VAC mains
with voltage selector switch to
settings not suitable for operation at
230 VAC.
No voltage selector.
N/A
5 Tropical
condition test
All appliances (with tropical test
requirements in applicable
Standards) shall comply with the
tropical condition test as stated in the
relevant IEC Standards.
requirements in applicable
Standards) shall comply with the
tropical condition test as stated in the
relevant IEC Standards.
Comply
P
Click on the first or last page to see other AVR 151 (serv.man5) service manuals if exist.