Harman Kardon AVR 151 (serv.man5) EMC - CB Certificate ▷ View online
Page 10 of 16
Report No.: 232173
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Z1
(A11:2008)
(A11:2008)
Add the following new clause after Clause 20:
Z1 Resistance to candle flame ignition
A television set shall be so designed that the
likelihood of ignition and the spread of fire caused
by a candle flame is reduced.
NOTE 1 An apparatus with a viewing screen is not
regarded to be a television set if it is declared not to
be so by the manufacturer.
This requirement does not apply to the display
screen of rear projection TV’s.
NOTE 2 This exemption has been allowed because
this technology is falling out of use and it is
expected that within a few years it will no longer
exist. This exemption will not be extended to other
technologies.
NOTE 3 The frame around the screen is not
exempted from the requirements.
Wood and WOOD-BASED MATERIAL with a
thickness of at least 6 mm is considered to fulfil the
V-1 requirement when applying CLC/TS 62441.
Compliance is checked according to CLC/TS
62441.
NOTE 4 The term vertical, as used in the first dash
of clause 5.2 of CLC/TS 62441, does not mean a
perfectly vertical position. It should be interpreted
as any surface that can be touched by the flame of
a candle of 150 mm height and 20mm diameter
while the candle is still touching the supporting
surface. A typical candle used in the home is
assumed to be 20 mm diameter.
NOTE 5 It is expected that CLC/TS 62441 will in
the future be replaced by a standard, at which time
that standard will become applicable, subject to a
vote by National Committees at the time.
Z1 Resistance to candle flame ignition
A television set shall be so designed that the
likelihood of ignition and the spread of fire caused
by a candle flame is reduced.
NOTE 1 An apparatus with a viewing screen is not
regarded to be a television set if it is declared not to
be so by the manufacturer.
This requirement does not apply to the display
screen of rear projection TV’s.
NOTE 2 This exemption has been allowed because
this technology is falling out of use and it is
expected that within a few years it will no longer
exist. This exemption will not be extended to other
technologies.
NOTE 3 The frame around the screen is not
exempted from the requirements.
Wood and WOOD-BASED MATERIAL with a
thickness of at least 6 mm is considered to fulfil the
V-1 requirement when applying CLC/TS 62441.
Compliance is checked according to CLC/TS
62441.
NOTE 4 The term vertical, as used in the first dash
of clause 5.2 of CLC/TS 62441, does not mean a
perfectly vertical position. It should be interpreted
as any surface that can be touched by the flame of
a candle of 150 mm height and 20mm diameter
while the candle is still touching the supporting
surface. A typical candle used in the home is
assumed to be 20 mm diameter.
NOTE 5 It is expected that CLC/TS 62441 will in
the future be replaced by a standard, at which time
that standard will become applicable, subject to a
vote by National Committees at the time.
No television set.
N/A
General 13.3.1
Delete note 4.
14
Delete note 4 and note 5.
15.1.1
Delete notes 1 and 2.
15.2
Delete note 2.
16.1
Delete note 1.
16.2
Delete the note.
20
Delete note 2.
Annex B
Replace note 1 by: In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Annex G
Delete the note.
Annex J.2
Delete the notes of Table J.1.
Annex N
Add after the introduction: For ROUTINE TEST reference is made to
EN 50333. (Replaced by EN 50514)
—
Page 11 of 16
Report No.: 232173
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
General
(A2:2010)
(A2:2010)
In IEC 60065:2001/A2
Delete all the “country” notes according to the following list:
5.3
Delete all the “country” notes according to the following list:
5.3
Note
5.4.1 Note
20
20
Note
For special national conditions, see Annex ZB.
—
Bibliograph
y
y
Additional EN standards.
—
ZA
Normative references to international publications
with their corresponding European publications
with their corresponding European publications
—
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
2.6.1
DK: The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Class II apparatus.
N/A
3.Z1
(A2:2010)
(A2:2010)
Denmark
Add to the end of the subclause
Due to many existing installations where the
socket-outlets can be protected with
fuses with higher rating than the rating of the
socket-outlets the protection for
pluggable equipment type A shall be an integral
part of the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse.
Add to the end of the subclause
Due to many existing installations where the
socket-outlets can be protected with
fuses with higher rating than the rating of the
socket-outlets the protection for
pluggable equipment type A shall be an integral
part of the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse.
No socket-outlets.
N/A
Page 12 of 16
Report No.: 232173
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
5.3
(A2:2010)
(A2:2010)
Finland, Norway and Sweden
To the end of the subclause the following is added:
To the end of the subclause the following is added:
CLASS I
apparatus which is intended for connection
to the building installation wiring
via a plug or an appliance coupler, or both and in
addition is intended for connection
to other apparatus or a network shall, if safety
relies on connection to protective earth
or if surge suppressors are connected between the
network
via a plug or an appliance coupler, or both and in
addition is intended for connection
to other apparatus or a network shall, if safety
relies on connection to protective earth
or if surge suppressors are connected between the
network
TERMINALS
and
ACCESSIBLE
parts, have a marking stating that the
apparatus must be connected to an
earthed
earthed
MAINS
socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
Class II apparatus.
N/A
5.4
(A11:2008)
(A11:2008)
Finland, Norway and Sweden
To the end of 5.4 the following is added:
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an MAINS socket-outlet with
protective earth.
The marking text in the applicable countries shall
be as follows:
In Finland: “Laite on liitettävä
suojamaadoituskoskettimilla varustettuun
pistorasiaan”
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: "Apparaten skall anslutas till jordat
uttag"
To the end of 5.4 the following is added:
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an MAINS socket-outlet with
protective earth.
The marking text in the applicable countries shall
be as follows:
In Finland: “Laite on liitettävä
suojamaadoituskoskettimilla varustettuun
pistorasiaan”
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: "Apparaten skall anslutas till jordat
uttag"
Class II apparatus.
N/A
Page 13 of 16
Report No.: 232173
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
5.4.1
(A11:2008)
(A11:2008)
Norway and Sweden
To the end of 5.4.1 (after the compliance
statement) the following is added:
The screen of the cable distribution system is
normally not earthed at the entrance of the building
and there is normally no equipotential bonding
system within the building. Therefore the protective
earthing of the building installation need to be
isolated from the screen of a cable distribution
system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)”
To the end of 5.4.1 (after the compliance
statement) the following is added:
The screen of the cable distribution system is
normally not earthed at the entrance of the building
and there is normally no equipotential bonding
system within the building. Therefore the protective
earthing of the building installation need to be
isolated from the screen of a cable distribution
system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr – og
er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved tilkopling
av utstyret til kabel-TV nettet installeres en
galvanisk isolator mellom utstyret og kabel-TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och
samtidigt är kopplad till kabel-TV nät kan i vissa fall
medföra risk för brand.
Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator
finnas mellan utrustningen och kabel-TV nätet.”
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr – og
er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved tilkopling
av utstyret til kabel-TV nettet installeres en
galvanisk isolator mellom utstyret og kabel-TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och
samtidigt är kopplad till kabel-TV nät kan i vissa fall
medföra risk för brand.
Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator
finnas mellan utrustningen och kabel-TV nätet.”
No CDS
N/A
Click on the first or last page to see other AVR 151 (serv.man5) service manuals if exist.