Harman Kardon AVR 151 (serv.man5) EMC - CB Certificate ▷ View online
Page 1 of 6
Report No.: 232173
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
CHINA NATIONAL DIFFERENCES
Test results according to Online CB BULLETIN (Last modification date of 2012-06-06)
Differences according .................... : IEC 60065, 7th edition (2001)+Amendment 1 (2005)
Corresponding National Standard GB 8898-2011
No.
Requirement – Test
Result - Remark
Verdict
1.1.3
Amended the first paragraph:
This standard applies to apparatus intended to be
used basically at altitudes not exceeding 5 000 m,
dry climate at warm temperate zone or tropical
climates.
This standard applies to apparatus intended to be
used basically at altitudes not exceeding 5 000 m,
dry climate at warm temperate zone or tropical
climates.
Noted
The fourth paragraph replaced by following:
For apparatus intended to be used in vehicles,
ships or aircraft, or at altitudes exceeding
5 000m, additional requirements may be necessary.
For apparatus intended to be used in vehicles,
ships or aircraft, or at altitudes exceeding
5 000m, additional requirements may be necessary.
The apparatus intended to be
operated at altitudes up to
2 000m.
operated at altitudes up to
2 000m.
N/A
5
At the end of the first paragraph ,added following:
For apparatus intended to be used at altitude not
exceeding 2000m, a warning label containing the
following or a similar appropriate wording or a
symbol as in annex R(see following) shall fixed to
the equipment at readily visible place.
"Only used at altitude not exceeding 2000m."
For apparatus intended to be used at altitude not
exceeding 2000m, a warning label containing the
following or a similar appropriate wording or a
symbol as in annex R(see following) shall fixed to
the equipment at readily visible place.
"Only used at altitude not exceeding 2000m."
If only symbol used, the explanation of the symbol
shall be contained in the instruction manual.
shall be contained in the instruction manual.
The apparatus intended to
be operated at altitudes up to
2 000m, and a
be operated at altitudes up to
2 000m, and a
ppropriate
wording provided as follows,
See copy of marking plate.
P
Page 2 of 6
Report No.: 232173
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
For apparatus intended to be used in not-tropical
climate regions, a warning label containing the
following or a similar appropriate wording or a
symbol as in annex R shall fixed to the equipment
at readily visible place.
"Only used in not-tropical climate regions."
climate regions, a warning label containing the
following or a similar appropriate wording or a
symbol as in annex R shall fixed to the equipment
at readily visible place.
"Only used in not-tropical climate regions."
If only symbol used, the explanation of the symbol
shall be contained in the instruction manual.
The statements above shall be given in a language
acceptable to the regions where the apparatus is
intended to be used.
shall be contained in the instruction manual.
The statements above shall be given in a language
acceptable to the regions where the apparatus is
intended to be used.
The apparatus intended to
be used in not tropical climate
regions, and a
be used in not tropical climate
regions, and a
ppropriate
wording provided as follows
See copy of marking plate.
P
5.1 e)
After the last paragraph, added:
…….For single rated voltage, “220 V” or three-
phase “380V” shall be marked only. For a rating
range, 220 V or three-phase 380V shall be covered.
For multiple rated voltages, one of them shall be
220 V or three-phase 380V and which default
setting from manufacture shall be 220 V or three-
phase 380V as well.
…….For single rated voltage, “220 V” or three-
phase “380V” shall be marked only. For a rating
range, 220 V or three-phase 380V shall be covered.
For multiple rated voltages, one of them shall be
220 V or three-phase 380V and which default
setting from manufacture shall be 220 V or three-
phase 380V as well.
Covered
P
5.1 f)
After the first sentence, Added:
……for Rated MAINS frequency or frequency range
shall be 50Hz or covered 50Hz.
……for Rated MAINS frequency or frequency range
shall be 50Hz or covered 50Hz.
Rated MAINS frequency of
50Hz covered.
50Hz covered.
P
5.4
Replaced the second sentence of the first
paragraph:
This information shall be given in normative
Chinese.
paragraph:
This information shall be given in normative
Chinese.
Adequate instruction supplied
by Chinese manual with the
apparatus.
by Chinese manual with the
apparatus.
P
5.4.1i)
Added new paragraph i),after the h) paragraph:
i) For apparatus incorporating antenna coaxial
sockets witch is non-separated with CATV network,
a warning wording or a similar shall be given in the
instructions manual:
“The CATV network connecting to this apparatus
shall separate from protective earth, otherwise it
may cause fire or other hazard.”
i) For apparatus incorporating antenna coaxial
sockets witch is non-separated with CATV network,
a warning wording or a similar shall be given in the
instructions manual:
“The CATV network connecting to this apparatus
shall separate from protective earth, otherwise it
may cause fire or other hazard.”
No CDS
N/A
Page 3 of 6
Report No.: 232173
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
7 ,Table3 Note a) of table 3 replaced:
This standard applies to apparatus intended to be
used in tropical climates, permissible temperature
rises are 10 K less than those specified in the table.
For apparatus intended to be used in non-tropical
climates the limits in Table 3 are satisfactory.
used in tropical climates, permissible temperature
rises are 10 K less than those specified in the table.
For apparatus intended to be used in non-tropical
climates the limits in Table 3 are satisfactory.
The apparatus intended to
be used in not tropical climate
regions
be used in not tropical climate
regions
N/A
7.1
Added Note 3:
For apparatus intended to be operated at altitudes
between 2 000m and 5 000m, temperature
measuring conditions and maximum temperature
limits are under consideration.
For apparatus intended to be operated at altitudes
between 2 000m and 5 000m, temperature
measuring conditions and maximum temperature
limits are under consideration.
9.1.1.1
Delete the note 3 and renumber the existing note 4
as 3.
as 3.
N/A
9.1.1.1
After the paragraph of d), added a paragraph:
For apparatus intended to be used in tropical
climates, the limits should be halved than the
values given in a) and b) above.
For apparatus intended to be used in tropical
climates, the limits should be halved than the
values given in a) and b) above.
The apparatus intended to
be used in not tropical climate
regions
be used in not tropical climate
regions
N/A
10
Added a paragraph after the second paragraph :
The Insulation resistance between CATV antenna
coaxial sockets and protective earth of apparatus
shall comply with BASIC INSULATION. If it’s
possible that CLASS II apparatus with CATV
antenna coaxial sockets connect with protective
earth of another CLASS I apparatus by other
terminals, the insulation resistance between them
shall comply with BASIC INSULATION as well.
Added Note:
if antenna cable separated from the protective earth
before connection to the apparatus, there is no
requirements of Insulation resistance between them
but 5.4.1i) requirements shall be meet.
The Insulation resistance between CATV antenna
coaxial sockets and protective earth of apparatus
shall comply with BASIC INSULATION. If it’s
possible that CLASS II apparatus with CATV
antenna coaxial sockets connect with protective
earth of another CLASS I apparatus by other
terminals, the insulation resistance between them
shall comply with BASIC INSULATION as well.
Added Note:
if antenna cable separated from the protective earth
before connection to the apparatus, there is no
requirements of Insulation resistance between them
but 5.4.1i) requirements shall be meet.
No CDS
N/A
10.1
Delete “on CLASS II apparatus” in the first
paragraph.
paragraph.
Considered.
P
Page 4 of 6
Report No.: 232173
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
10.2
Replaced the fifth to seventh paragraphs by the
following:
The humidity treatment is carried out in a chamber
containing air with a relative humidity of 93%±3 %.
For apparatus, temperature of 40℃±2℃ and a
relative humidity of 93%±3% shall be subjected.
Apparatus intended to be used in non-tropical
climates are subjected to a relative humidity of
93%±3%.
The temperature in the chamber, at all places
where samples located, shall be maintained within
2℃of any convenient value between 20℃ and
30℃, as long as no condensation occur.
following:
The humidity treatment is carried out in a chamber
containing air with a relative humidity of 93%±3 %.
For apparatus, temperature of 40℃±2℃ and a
relative humidity of 93%±3% shall be subjected.
Apparatus intended to be used in non-tropical
climates are subjected to a relative humidity of
93%±3%.
The temperature in the chamber, at all places
where samples located, shall be maintained within
2℃of any convenient value between 20℃ and
30℃, as long as no condensation occur.
The apparatus intended to
be used in not tropical climate
regions, however p
be used in not tropical climate
regions, however p
erformed
for 120 h at temp. 40
C and
humidity 93 %.
N/A
Added Note 4: For apparatus intended to be
operated at altitudes between 2 000m and 5 000m,
the requirements for treatment of the insulating
material are under consideration.
operated at altitudes between 2 000m and 5 000m,
the requirements for treatment of the insulating
material are under consideration.
Noted.
11.1
Delete note 2.
Noted
11.1
After the ninth paragraph added a paragraph:
For apparatus intended to be used in tropical
climates, halve the values given above.
For apparatus intended to be used in tropical
climates, halve the values given above.
The apparatus intended to
be used in not tropical climate
regions
be used in not tropical climate
regions
N/A
12.5
Amended the first paragraph :
Antenna coaxial sockets to be mounted on the
apparatus shall subject to mechanical stress
caused in use, and the sockets incorporate with
parts or components which isolated HAZARDOUS
LIVE parts from ACCESSIBLE parts or protective
earth from other terminals.
Antenna coaxial sockets to be mounted on the
apparatus shall subject to mechanical stress
caused in use, and the sockets incorporate with
parts or components which isolated HAZARDOUS
LIVE parts from ACCESSIBLE parts or protective
earth from other terminals.
No such antenna
N/A
13.3.2
After the first paragraph, added a paragraph:
The requirements apply to apparatus intended to be
used at altitude not exceeding 2 000 m . For
apparatus intended to be operated at altitudes
between 2 000m and 5 000m , Minimum
CLEARANCE limits shall multiply with multiplication
factor 1.48 in table A.2 of GB/T 16935.1. For
apparatus intended to be operated at altitude more
than 5 000m , Minimum CLEARANCES limit shall
multiply with relevant multiplication factor in table
A.2 of GB/T 16935.1.
The requirements apply to apparatus intended to be
used at altitude not exceeding 2 000 m . For
apparatus intended to be operated at altitudes
between 2 000m and 5 000m , Minimum
CLEARANCE limits shall multiply with multiplication
factor 1.48 in table A.2 of GB/T 16935.1. For
apparatus intended to be operated at altitude more
than 5 000m , Minimum CLEARANCES limit shall
multiply with relevant multiplication factor in table
A.2 of GB/T 16935.1.
The apparatus intended to
be operated at altitudes up to
2 000m.
be operated at altitudes up to
2 000m.
N/A
Click on the first or last page to see other AVR 151 (serv.man5) service manuals if exist.