Page 1 of 6 
Report No.: 232173 
 
ATTACHMENT 6 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
  
TRF No. IEC60065K 
 
CHINA NATIONAL DIFFERENCES 
Test results according to Online CB BULLETIN (Last modification date of 2012-06-06) 
Differences according .................... :  IEC 60065, 7th edition (2001)+Amendment 1 (2005) 
Corresponding National Standard  GB 8898-2011 
No. 
Requirement – Test 
Result - Remark 
Verdict 
1.1.3 
Amended the first paragraph: 
This standard applies to apparatus intended to be 
used basically at altitudes not exceeding 5 000 m, 
dry climate at warm temperate zone or tropical 
climates. 
Noted 
 
 
The fourth paragraph replaced by following: 
For apparatus intended to be used in vehicles, 
ships or aircraft, or at altitudes exceeding  
5 000m, additional requirements may be necessary.
The apparatus intended to be 
operated at altitudes up to  
2 000m.
 
N/A 
At the end of the first paragraph ,added following: 
For apparatus intended to be used at altitude not 
exceeding 2000m, a warning label containing the 
following or a similar appropriate wording or a 
symbol as in annex R(see following) shall fixed to 
the equipment at readily visible place. 
"Only used at altitude not exceeding 2000m."  
 
If only symbol used, the explanation of the symbol 
shall be contained in the instruction manual. 
  
The apparatus intended to  
be operated at altitudes up to  
2 000m, and a
ppropriate  
wording provided as follows, 
 
See copy of marking plate. 
 
Page 2 of 6 
Report No.: 232173 
 
ATTACHMENT 6 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
  
TRF No. IEC60065K 
 
 
For apparatus intended to be used in not-tropical 
climate regions, a warning label containing the 
following or a similar appropriate wording or a 
symbol as in annex R shall fixed to the equipment 
at readily visible place. 
"Only used in not-tropical climate regions." 
 
If only symbol used, the explanation of the symbol 
shall be contained in the instruction manual. 
 
The statements above shall be given in a language 
acceptable to the regions where the apparatus is 
intended to be used. 
The apparatus intended to  
be used in not tropical climate 
regions, and a
ppropriate  
wording provided as follows 
 
See copy of marking plate. 
5.1 e) 
After the last paragraph, added: 
…….For single rated voltage, “220 V” or three-
phase “380V” shall be marked only. For a rating 
range, 220 V or three-phase 380V shall be covered. 
For multiple rated voltages, one of them shall be 
220 V or three-phase 380V and which default 
setting from manufacture shall be 220 V or three-
phase 380V as well. 
Covered 
5.1 f) 
After the first sentence, Added: 
……for Rated MAINS frequency or frequency range 
shall be 50Hz or covered 50Hz. 
Rated MAINS frequency of 
50Hz covered. 
5.4 
Replaced the second sentence of the first 
paragraph: 
This information shall be given in normative 
Chinese. 
Adequate instruction supplied 
by Chinese manual with the 
apparatus.
 
5.4.1i) 
Added new paragraph i),after the h) paragraph: 
i) For apparatus incorporating antenna coaxial 
sockets witch is non-separated with CATV network, 
a warning wording or a similar shall be given in the 
instructions manual:  
“The CATV network connecting to this apparatus 
shall separate from protective earth, otherwise it 
may cause fire or other hazard.” 
No CDS 
N/A 
Page 3 of 6 
Report No.: 232173 
 
ATTACHMENT 6 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
  
TRF No. IEC60065K 
 
7 ,Table3  Note a) of table 3 replaced: 
This standard applies to apparatus intended to be 
used in tropical climates, permissible temperature 
rises are 10 K less than those specified in the table. 
For apparatus intended to be used in non-tropical 
climates the limits in Table 3 are satisfactory. 
The apparatus intended to  
be used in not tropical climate 
regions
 
N/A 
7.1 
Added Note 3:  
For apparatus intended to be operated at altitudes 
between 2 000m and 5 000m, temperature 
measuring conditions and maximum temperature 
limits are under consideration. 
 
 
9.1.1.1 
Delete the note 3 and renumber the existing note 4 
as 3. 
 N/A 
9.1.1.1 
After the paragraph of d), added a paragraph: 
For apparatus intended to be used in tropical 
climates, the limits should be halved than the 
values given in a) and b) above. 
The apparatus intended to  
be used in not tropical climate 
regions
 
N/A 
10 
Added a paragraph after the second paragraph : 
The Insulation resistance between CATV antenna 
coaxial sockets and protective earth of apparatus 
shall comply with BASIC INSULATION. If it’s 
possible that CLASS II apparatus with CATV 
antenna coaxial sockets connect with protective 
earth of another CLASS I apparatus by other 
terminals, the insulation resistance between them 
shall comply with BASIC INSULATION as well. 
Added Note: 
if antenna cable separated from the protective earth 
before connection to the apparatus, there is no 
requirements of Insulation resistance between them 
but 5.4.1i) requirements shall be meet. 
No CDS 
N/A 
10.1 
Delete “on CLASS II apparatus” in the first 
paragraph. 
Considered. 
Page 4 of 6 
Report No.: 232173 
 
ATTACHMENT 6 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
  
TRF No. IEC60065K 
 
10.2 
Replaced the fifth to seventh paragraphs by the 
following: 
The humidity treatment is carried out in a chamber 
containing air with a relative humidity of 93%±3 %. 
For apparatus, temperature of 40℃±2℃ and a 
relative humidity of 93%±3% shall be subjected. 
Apparatus intended to be used in non-tropical 
climates are subjected to a relative humidity of 
93%±3%.  
The temperature in the chamber, at all places 
where samples located, shall be maintained within 
2℃of any convenient value between 20℃ and 
30℃, as long as no condensation occur. 
The apparatus intended to  
be used in not tropical climate 
regions, however p
erformed 
for 120 h at temp. 40 
C and 
humidity 93 %. 
N/A 
 
Added Note 4: For apparatus intended to be 
operated at altitudes between 2 000m and 5 000m, 
the requirements for treatment of the insulating 
material are under consideration. 
Noted. 
 
11.1 
Delete note 2. 
Noted 
 
11.1 
After the ninth paragraph added a paragraph: 
For apparatus intended to be used in tropical 
climates, halve the values given above. 
The apparatus intended to  
be used in not tropical climate 
regions
 
N/A 
12.5 
Amended the first paragraph : 
Antenna coaxial sockets to be mounted on the 
apparatus shall subject to mechanical stress 
caused in use, and the sockets incorporate with 
parts or components which isolated HAZARDOUS 
LIVE parts from ACCESSIBLE parts or protective 
earth from other terminals.  
No such antenna 
N/A 
13.3.2 
After the first paragraph, added a paragraph: 
The requirements apply to apparatus intended to be 
used at altitude not exceeding 2 000 m . For 
apparatus intended to be operated at altitudes 
between 2 000m and 5 000m , Minimum 
CLEARANCE limits shall multiply with multiplication 
factor 1.48 in table A.2 of GB/T 16935.1. For 
apparatus intended to be operated at altitude more 
than 5 000m , Minimum CLEARANCES limit shall 
multiply with relevant multiplication factor in table 
A.2 of GB/T 16935.1.     
The apparatus intended to  
be operated at altitudes up to  
2 000m.
 
N/A 
Page of 106