Sony VPL-VW85 Service Manual ▷ View online
1-27 (E)
VPL-VW85
1-9-4. Data Write Method of LookUpTable/3DGamma/ABGamma/LCK/OGMTable/
CSMatrixTable
1.
Connect the AC plug and set this unit to standby state.
2.
Check the Standby Mode is set to “Standard”. (Refer
to section 1-9-1 “Preparation”.)
to section 1-9-1 “Preparation”.)
3.
When LookUpTable, 3DGamma, ABGamma or LCK
data writing, press the [ON/STANDBY] button to
light the lamp.
data writing, press the [ON/STANDBY] button to
light the lamp.
4.
Double-click QuickAccess.exe to start the application.
Application name:
3DGamma QuickAccess
Execution file name: QuickAccess.exe
Version:
Version:
8.20 or later
5.
Select “VPL-VW85” on the Model pull-down menu.
6.
Select Load on the Load/Save pull-down menu.
7.
Select the data type (LookUpTable/3DGamma/
ABGamma/LCK/OGMTable/CSMatrixTable) on the
3dgm/Lut pulldown menu.
ABGamma/LCK/OGMTable/CSMatrixTable) on the
3dgm/Lut pulldown menu.
8.
Click the [Next] button.
9.
Select the serial port used for connecting PC on the
Serial Port pull-down menu.
Serial Port pull-down menu.
Upper box: Serial port number used for connecting PC
Lower box: 38400
Lower box: 38400
10. Click the [Next] button.
11. Select “ALL” on the Load field.
12. Check the Verify check box.
13. Click the [Browse...] button and select the data file to
11. Select “ALL” on the Load field.
12. Check the Verify check box.
13. Click the [Browse...] button and select the data file to
be written.
14. Click the [Next] button.
The massage “There is a wrong file. To continue push
YES.” appears.
YES.” appears.
15. Click the [YES] button.
The writing is performed.
When completed, the massage “Turn Off and On the
AC, and then Power On to enable the new settings.”
appears.
When completed, the massage “Turn Off and On the
AC, and then Power On to enable the new settings.”
appears.
16. Click the [OK] button.
17. Turn off the power and disconnect and connect the AC
17. Turn off the power and disconnect and connect the AC
plug, to restart this unit.
18. Click the [Complete] button.
1-28 (E)
VPL-VW85
1-9-5. Data Obtain Method of LookUpTable/3DGamma/ABGamma/LCK/
OGMTable/CSMatrixTable from the Board
1.
Connect the AC plug and set this unit to standby state.
2.
When LookUpTable, 3DGamma, ABGamma or LCK
data reading, press the [ON/STANDBY] button to
light the lamp.
data reading, press the [ON/STANDBY] button to
light the lamp.
3.
Double-click QuickAccess.exe to start the application.
Application name:
3DGamma QuickAccess
Execution file name: QuickAccess.exe
Version:
Version:
8.20 or later
4.
Select “VPL-VW85” on the Model pull-down menu.
5.
Select Save on the Load/Save pull-down menu.
6.
Select the data type (LookUpTable/3DGamma/
ABGamma/LCK/OGMTable/CSMatrixTable) on the
3dgm/Lut pulldown menu.
ABGamma/LCK/OGMTable/CSMatrixTable) on the
3dgm/Lut pulldown menu.
7.
Click the [Next] button.
8.
Select the serial port used for connecting PC on the
Serial Port pull-down menu.
Serial Port pull-down menu.
Upper box: Serial port number used for connecting PC
Lower box: 38400
Lower box: 38400
9.
Click the [Next] button.
10. Select “SAVE_ALL” on the Save field.
11. Check the Verify check box.
12. Type an arbitrary file name on the File Name field.
13. Click the [Next] button.
11. Check the Verify check box.
12. Type an arbitrary file name on the File Name field.
13. Click the [Next] button.
The reading is performed.
When completed, the massage “Verify Success!
Reading Model Name, Serial Number, NVM Map
Version and NVM Data Version is successful.”
appears.
When completed, the massage “Verify Success!
Reading Model Name, Serial Number, NVM Map
Version and NVM Data Version is successful.”
appears.
14. Click the [OK] button.
15. Turn off the power of this unit.
16. Click the [Complete] button.
15. Turn off the power of this unit.
16. Click the [Complete] button.
1-29 (E)
VPL-VW85
1-10.
Memory
Memory structure consists of the following memory
blocks.
1.
blocks.
1.
Set Memory
2.
Status Memory
3.
Video Chroma Memory
4.
W/B Memory
5.
Channel Memory
6.
Installation Memory
7.
Picture Memory
8.
RCP Memory
9.
FAN Memory
10. UF Memory
11. LUT Memory
12. Sub Micro Memory
13. Panel Alignment Memory
14. Gamma Memory
11. LUT Memory
12. Sub Micro Memory
13. Panel Alignment Memory
14. Gamma Memory
External NVM (EEPROM) : 256 kbit
External NVM
Memory : Save the Data from
CPU RAM to NVM
CPU RAM to NVM
Initialize : Reset the Data to default value
Active memory copy : Load the Data from NVM to CPU RAM
External NVM
CPU RAM
No.01
No.02
No.03
No.04
Status
Memory
Memory
No.99
Status Memory
Set Memory
Set Memory
Set Memory
1.
2.
No.01
No.02
No.02
No.03
No.04
No.04
No.99
No.101
Input-A
User
No.120
No.03
No.04
No.04
Component
Preset
No.99
No.03
No.04
No.03
No.04
Status
Memory
Memory
HDMI1
Preset
No.99
No.03
No.04
No.03
No.04
HDMI2
Preset
No.99
Input-A
Preset
When the power is turned on to the projector, all data
inside the internal ROM are written into the NVM (Non-
volatile Memory).
When the power is turned to on to the projector, required
data for the current picture, such as status memory data,
etc., are selected from the respective memory blocks, and
are written into the internal RAM. When adjustment is
carried out, adjustment data are written into the NVM
automatically (items on the user mode) or by the trigger of
memory operation (items on the service mode), then stored
them. Be careful that the factory preset (adjusted) data of
the user adjustable items are all eliminated from the
memory when user performs adjustment of the adjustable
items (W/B and Device Adjust) and the memory operation
to memorize the user adjustment data into the NVM.
inside the internal ROM are written into the NVM (Non-
volatile Memory).
When the power is turned to on to the projector, required
data for the current picture, such as status memory data,
etc., are selected from the respective memory blocks, and
are written into the internal RAM. When adjustment is
carried out, adjustment data are written into the NVM
automatically (items on the user mode) or by the trigger of
memory operation (items on the service mode), then stored
them. Be careful that the factory preset (adjusted) data of
the user adjustable items are all eliminated from the
memory when user performs adjustment of the adjustable
items (W/B and Device Adjust) and the memory operation
to memorize the user adjustment data into the NVM.
* When the power to the projector is turned off without memorizing the
adjustment data, the original factory preset (adjusted) data can be restored
by removing the power cord once and connect it back again.
by removing the power cord once and connect it back again.
1-30 (E)
VPL-VW85
High
Middle
Low1
Low2
Low2
Custom1
Custom2
Custom2
Custom3
Custom4
Custom5
Custom4
Custom5
Iris:Off
W/B
Memory
Memory
High
Middle
Low2
Low1
Custom1
Custom2
Custom2
Custom3
Custom5
Custom4
High
Middle
Low2
Low1
Custom1
Custom2
Custom2
Custom3
Custom5
Custom4
Video
S Video
Input-A
Component
HDMI 1
HDMI 2
HDMI 2
Video
S Video
Input-A
Component
HDMI 1
HDMI 2
HDMI 2
ImageFlip : off/H
ImageFlip : HV/V
W/B
Memory
High
Low 1
Low 2
Custom 1
Custom 2
Custom 3
Custom 4
Custom 5
Installation
Memory
Installation Memory
Channel
Memory
5.
6.
4.
3.
Channel
Memory
Channel Memory
Middle
Iris:On/Manual
Iris:Auto/Auto1/
Auto2
Noinput
NTSC3.58
NTSC4.43
PAL
PALM
PALN
SECAM
BW60
BW50
Video
Chroma
Memory
[Video]
Chroma
Memory
[Video]
PAL60
Noinput
NTSC3.58
NTSC4.43
PAL
PALM
PALN
SECAM
BW60
BW50
Video
Chroma
Memory
[SVideo]
Chroma
Memory
[SVideo]
PAL60
Video Chroma Memory