DOWNLOAD Sony HDR-UX3E / HDR-UX5 / HDR-UX5E / HDR-UX7 / HDR-UX7E (serv.man3) Service Manual ↓ Size: 1.42 MB | Pages: 67 in PDF or view online for FREE

Model
HDR-UX3E HDR-UX5 HDR-UX5E HDR-UX7 HDR-UX7E (serv.man3)
Pages
67
Size
1.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-ux3e-hdr-ux5-hdr-ux5e-hdr-ux7-hdr-ux7e-sm3.pdf
Date

Sony HDR-UX3E / HDR-UX5 / HDR-UX5E / HDR-UX7 / HDR-UX7E (serv.man3) Service Manual ▷ View online

6-54
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
2.
Switch Check
Click the [Switch Check] button on the SERVICE MODE screen,
and the “SWITCH CHECK” screen will appear.
Using method:
Click the [Start] button, and the switch check will start.
During execution of switch check, the pressed switch is displayed
in orange. Also, once the switch was pressed, its name characters
change to blue in color.
3-2.
SERVICE  MODE
1.
Function of Each Button on Service Mode Screen
Click the [SERVICE MODE] button on the Main Menu screen, and
the “SERVICE MODE” screen in Fig. 6-3-2 will appear.
Fig. 6-3-2
1
[To Menu] button
The Main Menu screen comes back.
2
[Switch Check] button
“SWITCH CHECK” screen appears.
3
[LED Check] button
“LED CHECK” screen appears.
4
[Jack Check] button
“JACK CHECK” screen appears.
5
[Lens Barrier Check] button
“LENS BARRIER CHECK” screen appears.
6
[Record Data] button
“RECORD DATA” screen appears.
7
[Shift Lens Check] button
“SHIFT LENS CHECK” screen appears.
1
5
2
3
4
6
7
Ver. 1.5  2008.03
6-55
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
4.
Jack Check
Click the [Jack Check] button on the SERVICE MODE screen,
and the “JACK CHECK” screen will appear.
Using method:
Click the [Start] button, and the jack check will start.
During execution of jack check, the connected jack is displayed in
orange.
Note:
The HDMI OUT jack is displayed in orange when it is con-
nected to a unit that supports HDMI.
3.
LED Check
Click the [LED Check] button on the SERVICE MODE screen,
and the “LED CHECK” screen will appear.
Using method:
LED ON or OFF can be controlled with [LED ON] or [LED OFF]
button on the screen.
6-56
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
6.
Record Data
Click the [Record Data] button on the SERVICE MODE screen,
and the “RECORD DATA” screen will appear.
The record data such as use record and self-diagnostic record are
displayed.
Initializing method (Self-Diagnosis Data Only):
Click the [Clear Self-Diagnosis Data Only] button on the screen, and
the Self-Diagnosis Data will be initialized.
Note:
If a flash error (self-diagnosis code E:91:**) occurred, all
recorded data must be initialized to reset the error. The er-
ror cannot be reset by initializing the self-diagnosis data
only.
Initializing method (All Record-Data):
Click the [Clear All Recorded-Data] button on the screen, and the
All Recorded-Data will be initialized.
Note:
Performing the initialization causes all the user settings
including time setting to be initialized, too.
5.
Lens Barrier Check
Click the [Lens Barrier Check]  button on the SERVICE MODE
screen, and the “LENS BARRIER CHECK” screen will appear.
Using method:
The lens barrier open or close can be controlled with [OPEN] or
[CLOSE] button on the screen.
Ver. 1.5  2008.03
6-57
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
Ver. 1.5  2008.03
[Check 2 using method]
Use this menu when E:62:11 (Shift Lens Overheating (Pitch)) oc-
curred.
Click the [Check 2 Start] button, and the shift lens will move in up
and down directions. If the shift lens does not move, replace the
lens block.
[Check 3 using method]
Use this menu when E:62:12 (Shift Lens Overheating (Yaw)) oc-
curred.
Click the [Check 3 Start] button, and the shift lens will move in left
and right directions. If the shift lens does not move, replace the
lens block.
7.
Shift Lens Check
Use the “Shift Lens Check” when the following self diagnostic
codes are displayed.
• E:62:10 [Shift Lens Initializing Failure]
• E:62:11 [Shift Lens Overheating (Pitch)]
• E:62:12 [Shift Lens Overheating (Yaw)]
Click the [Shift Lens Check] button on the Service Mode screen,
and the “SHIFT LENS CHECK” screen will appear.
[Check 1 using method]
Use this menu when E:62:10 (Shift Lens Initializing Failure) oc-
curred.
Click the [Check 1 Start] button, and the “EEPROM Check” and
“Steady Hall Adjustment” will be executed.
• When “Steady Hall Adjustment” is executed, the shift lens will
move in up, down, left, and right directions. If the shift lens
does not move at all and a message “Shift Lens Check 1 Com-
plete” is displayed, or if an error message of Steady Hall Ad-
justment is displayed, replace the lens block.
• Check the peripheral circuits (particularly EEPROM (IC1804))
of the IC1803 on the VC-487 board, when the following mes-
sage is displayed.
Page of 67
Display

Click on the first or last page to see other HDR-UX3E / HDR-UX5 / HDR-UX5E / HDR-UX7 / HDR-UX7E (serv.man3) service manuals if exist.