DOWNLOAD Sony HDR-UX3E / HDR-UX5 / HDR-UX5E / HDR-UX7 / HDR-UX7E (serv.man3) Service Manual ↓ Size: 1.42 MB | Pages: 67 in PDF or view online for FREE

Model
HDR-UX3E HDR-UX5 HDR-UX5E HDR-UX7 HDR-UX7E (serv.man3)
Pages
67
Size
1.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-ux3e-hdr-ux5-hdr-ux5e-hdr-ux7-hdr-ux7e-sm3.pdf
Date

Sony HDR-UX3E / HDR-UX5 / HDR-UX5E / HDR-UX7 / HDR-UX7E (serv.man3) Service Manual ▷ View online

6-26
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
9.
CAMERA Adjustment 5
Note:
Before performing the defect adjustment, make sure that
the lens temperature of the camcorder exceeds 39 ºC.
[Preparation (Temperature Check)]
1) Click the [Preparation] button of the CAMERA Adjustment 5
to display the Preparation screen.
2) Click the [Temperature Check] button of the Preparation screen,
the following screen will appear.
[Checking method]
Click the [Start]  button of the Temperature Check, and the
camcorder will go in the Temperature Check mode and the tem-
perature check result will be displayed on the LCD screen. Per-
form the aging if the check result is NG (below 39 ºC). To exit the
Temperature Check mode, click the [Stop] button.
[Aging method]
Set the camcorder to the Movie mode, and place the LCD screen
in the “reverse-closed” state. (In this state, the temperature rises
more quickly than that in other states.)
Set the camcorder to the Temperature Check mode, and wait until
the LCD screen display changes from NG (grid pattern) to OK
(color bars).
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. HS White Defect Adj.
3. White Defect Adj.
4. White Defect Adj. (FD white point)
5. White Defect Check
6. Black Defect Adj.
7. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 5.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) If “1. Data Setting during Camera Adj.” completed success-
fully, and the items from “2. HS White Defect Adj.” to “5.
White Defect Check” will be executed.
4) If “5. White Defect Check” completed successfully, the fol-
lowing message is displayed. Set the subject in accordance
with the message.
5) Click the [OK] button, and the “6. Black Defect Adj.” will be
executed.
6) Upon completion of “6. Black Defect Adj.”, “7. Release of
Data Setting during Camera Adj.” is executed.
7) Upon successful completion of all items of the CAMERA Ad-
justment 5, the following message is displayed. Click the [OK]
button.
6-27
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
10. CAMERA Adjustment 6
Note:
“CAMERA Adjustment 6” is available only once after the
power is turned on. If the adjustment is retried, turn off the
power and turn on again.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Strobe Light Level Adj.
3. Strobe White Balance Adj.
4. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 6.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
(For the Flash adjustment box, refer to “4. Preparing the Flash
Adjustment Box” (see page 6-7).)
4) Press the [OK]  button, and the items “2. Strobe Light Level
Adj.” and “3. Strobe White Balance Adj.” will be executed.
5) Upon completion of “3. Strobe White Balance Adj.”, “4. Re-
lease of Data Setting during Camera Adj.” is executed
6) Upon successful completion of all items of the CAMERA Ad-
justment 6, the following message is displayed. Click the [OK]
button.
11. CAMERA Adjustment 7
(HDR-UX3E/UX5/UX5E only)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Steady Shot Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 7.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed.
With the camcoder in stationary state, click the [OK] button.
4) If the [OK] button is clicked, “2. Steady Shot Check” is ex-
ecuted.
Upon successful completion of the “2. Steady Shot Check”,
the following message is displayed. Check that the steadyshot
function operates normally in accordance with the message.
5) If the [OK] button is clicked, “3. Release of Data Setting dur-
ing Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 7, the following message is displayed. Click the
[OK] button.
6-28
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
1
2
3
4
1
2
3
4
SE7202
SE7201
CM-077 BOARD (SIDE A)
PP
YY
YAW sensor
 sensitivity  
t
 S
7201
PITCH sensor sensitivity  
t
 S
7202
12. CAMERA Adjustment 8  (HDR-UX7/UX7E only)
Perform this adjustment only when replacing the GYRO sensor or
lens block. When the microprocessor, circuit etc. is damaged, don’t
perform this adjustment but check the operations only.
12-1. Preparation when the GYRO sensor or the CM-
077 board is replaced
Note down the sensitivity displayed on the GYRO sensor of the re-
pair parts. At this time, note down also to which board it was attached
to.
Be sure to check because if attached incorrectly, the screen will vi-
brate up and down or left and right during the steady shot operations.
Precautions on the Parts Replacement
The PITCH sensor and the YAW sensor are different parts.
Precautions on GYRO Sensor
The sensor incorporates a precision oscillator. Handle it with care as
if it dropped, the balance of oscillator will be disrupted and opera-
tions will not be performed properly.
Adjustment Block
11
Adjustment Page
80
Adjustment Address
7F12, 7F13
Note:
The sensor sensitivity of SE7201 and SE7202 of the CM-
077 board is written only repair parts.
Preparation:
1) Read the PITCH sensor (CM-077 board SE7202) sensitivity
written on repair parts, and named this as S
7202
.
2) Read the YAW sensor (CM-077 board SE7201) sensitivity writ-
ten on repair parts, and named this as S
7201
.
Fig. 6-1-19
Ver. 1.5  2008.03
How to read the sensitivity data of GYRO sensor
With the pins 1 and 2 of GYRO sensor placed in the lower posi-
tion, read the data value.
Fig. 6-1-20
6 0
Hand Writing
1
2
4
3
For the sensor sensitivity value 60
Description example :
6-29
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
12-2. Preparation when the lens is replaced
Note down the PITCH/YAW data on the replacement lens for repair.
Adjustment Block
11
Adjustment Page
80
Adjustment Address
7F12, 7F13
Note:
The PITCH/YAW data of lens is written only repair parts.
Preparation:
1) Read the PITCH data written on repair parts, and named this
as L
1
.
2) Read the YAW data written on repair parts, and named this as
L
2
.
Fig. 6-1-21
12-3. GYRO Sensor Sensitivity Adjustment
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 8, and the fol-
lowing screen will appear.
2) Input the sensitivity of respective sensors (S
7201
, S
7202
) read at
“Preparation” into the screen.
If only either sensor was replaced, give a check to the checkbox
for the sensor not replaced at the lower left of the screen.
3) Input the PITCH/YAW data of lens (L
1
, L
2
) read at “Prepara-
tion” into the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
4) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
5) Upon successful completion of the data writing, the following
screen will appear. Check that the steady shot function oper-
ates normally.
YAW data    
t
 L
2
PITCH/YAW Data
PITCH data 
t
 L
1
X.XX / X.XX
Page of 67
Display

Click on the first or last page to see other HDR-UX3E / HDR-UX5 / HDR-UX5E / HDR-UX7 / HDR-UX7E (serv.man3) service manuals if exist.