Movie / SECTION 6 ADJUSTMENTS
File
hdr-ux3e-hdr-ux5-hdr-ux5e-hdr-ux7-hdr-ux7e-sm3.pdf
Date

Sony HDR-UX3E / HDR-UX5 / HDR-UX5E / HDR-UX7 / HDR-UX7E (serv.man3) Service Manual ▷ View online

6-50
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
Sensor
Purpose
Trouble Symptom
Cause
Repair
Faulty OP
Replace the MD block
Faulty Driver IC
Replace the MD board
Faulty connection of flexible
board
Check flexible board
Faulty OP
Replace the MD block
Faulty sensor, Faulty
connection of flexible board
Temperature sensor
t Replace the MD block
Dew sensor
t Check flexible board
Shock sensor
t Replace the MD board
OP age-based change
Replace the MD block
Faulty operation of
mechanism
Replace the MD block
Faulty DSP IC
Replace the MD board
Faulty RF IC
Replace the MD board
Seek
Purpose
Trouble Symptom
Cause
Repair
Check the seek performance
OP age-based change
Readjust
Faulty mechanism
Replace the MD block
Faulty DSP IC
Replace the MD board
Faulty RF IC
Replace the MD board
Read
Purpose
Trouble Symptom
Cause
Repair
Check the read performance
OP age-based change
Readjust
LPP Error Rate, RF Jitter
Faulty mechanism
Replace the MD block
Faulty DSP IC
Replace the MD board
Faulty RF IC
Replace the MD board
Write
Purpose
Trouble Symptom
Cause
Repair
Check the write performance
OP age-based change
Readjust
Faulty mechanism
Replace the MD block
Faulty DSP IC
Replace the MD board
Faulty RF IC
Replace the MD board
Check operation of OP
 (Focus, Tracking, Sled,
Spindle)
Check the emission of laser
diode
During LPP/ADIP Error Rate,
RF Jitter
The following diagnosis is performed with DVD-R, DVD-RW and DVD+RDL
The diagnosis of DVD+RDL is performed with L0/L1 layer each layer.
Check various sensors
(Dew sensor, Temperature
sensor, Shock sensor)
(Seek between 2 points) 
x
5
x
2 patterns
t Calculation of
      average time
Disc type check
(only DVD-R)
2-6-2.
Diagnosis
6-51
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
Prepare, Sensor
Purpose
Trouble Symptom
Cause
Repair
Initialization of all data at
adjustment area
Faulty Flash IC
Replace the MD board
Check operation of Shock
sensor
Faulty shock sensor
Replace the MD board
Purpose
Trouble Symptom
Cause
Repair
Adjust the Laser power
Faulty connection to power
meter
Check connection to power
meter, Check power supply
Faulty installation of power
sensor jig
Check installation of power
sensor jig
Faulty lighting of LD
Check flexible board, Replace
the MD block
Faulty operation of
mechanism
Replace the MD block
Faulty RF IC
Replace the MD board
Faulty DSP IC
Replace the MD board
Faulty SDRAM IC
Replace the MD board
Faulty Flash IC
Replace the MD board
Laser Power Adjustment
2-6-3.
Power Adjust
6-52
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
Purpose
Trouble Symptom
Cause
Repair
Faulty Flash IC
Replace the MD board
Faulty DSP IC
Replace the MD board
Purpose
Trouble Symptom
Cause
Repair
Adjust the servo with
DVD-RW
The disc is dirty or has
scratches on it
Check disc
Faulty OP
Replace the MD block
Faulty DSP IC
Replace the MD board
Faulty RF IC
Replace the MD board
DVD-RW Self Jitter
Purpose
Trouble Symptom
Cause
Repair
The disc is dirty or has
scratches on it
Check disc
Faulty OP
Replace the MD block
Faulty DSP IC
Replace the MD board
Faulty RF IC
Replace the MD board
DVD-R Self Jitter
Purpose
Trouble Symptom
Cause
Repair
The disc is dirty or has
scratches on it
Check disc
Faulty OP
Replace the MD block
Faulty DSP IC
Replace the MD board
Faulty RF IC
Replace the MD board
DVD+RDL Self Jitter
Purpose
Trouble Symptom
Cause
Repair
Adjust the servo with
DVD+RDL
The disc is dirty or has
scratches on it
Check disc
Faulty OP
Replace the MD block
Faulty DSP IC
Replace the MD board
Faulty RF IC
Replace the MD board
Data Dump
Purpose
Trouble Symptom
Cause
Repair
Faulty DSP IC
Replace the MD board
Faulty RF IC
Replace the MD board
The adjustment value is
dumped
Servo Parameter Initialize
Adjust the recording with
DVD+RDL
Check the self recording with
DVD+RDL
Initialization of servo-related
adjustment data
DVD-RW Reference Disc Adjustment
Adjust the recording with
DVD-RW
Check the self recording with
DVD-RW
Adjust the servo with DVD-R
Adjust the recording with
DVD-R
Check the self recording with
DVD-R
2-6-4.
Servo Adjust
6-53
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
6-3. SERVICE  MODE
3-1.
APPLICATION FOR ADJUSTMENT (SeusEX)
The adjustment software (SeusEX) can change operational coeffi-
cients of signal processing, EVR data, etc. same as the adjustment
remote commander. The SeusEX performs two-way communica-
tion between PC and camcorder using the USB terminal. The two-
way communication result data can be written in the nonvolatile
memory.
1.
Connection
1) Connect the HASP key to the USB terminal of the PC.
2) Connect the PC and camcorder with the USB cable.
3) Start the SeusEX on the PC.
4) Click  [Connect]  on the SeusEX screen. If the connection is
normal, the SeusEX screen will be as shown in Fig. 6-3-1,
indicating the “connected” state.
Note:
The SeusEX will go in “disconnect” state, if the
camcorder is turned off (for instance, by resetting the
set). In such a case, click [Connect]  on the SeusEX
screen to restore the “connected” state.
Fig. 6-3-1
2.
Operation
• Block change
To  change the block, click [Block]  on the SeusEX screen and
enter the block to be changed. The block is displayed in hexa-
decimal notation.
• Page change
To change the page, click [Page] on the SeusEX screen and en-
ter the page to be changed. The page is displayed in hexadeci-
mal notation.
• Address change
To  change the address, click [Address]  on the SeusEX screen
and enter the address to be changed. The address is displayed in
hexadecimal notation.
• Data change
To change the data, click [Set] on the SeusEX screen and enter
the data. The data is displayed in hexadecimal notation.
This operation does not write the data to the nonvolatile memory.
• Data writing
To write the data to the EEPROM, click [Write] on the SeusEX
screen and enter the data value to be written.
To  write the data to the flash memory, change the data value
using the [Set] on the SeusEX screen and then click [Save] to
save the data.
• Data reading
The data displayed on the SeusEX screen are the data values at
the time when the pages and addresses were set, and they are
not updated automatically. To check the data change, click [Read]
on the SeusEX screen and update the displayed data.