Sony HDR-SR5 / HDR-SR5C / HDR-SR5E / HDR-SR7 / HDR-SR7E / HDR-SR8 / HDR-SR8E (serv.man4) Service Manual ▷ View online
6-40
HDR-SR5/SR5C/SR5E/SR7/SR7E/SR8/SR8E_ADJ
4.
Jack Check
Click the [Jack Check] button on the SERVICE MODE screen,
and the “JACK CHECK” screen will appear.
and the “JACK CHECK” screen will appear.
Using method:
Click the [Start] button, and the jack check will start.
During execution of jack check, the connected jack is displayed in
orange.
Click the [Start] button, and the jack check will start.
During execution of jack check, the connected jack is displayed in
orange.
Note:
The HDMI OUT jack is displayed in orange when it is con-
nected to a unit that supports HDMI.
nected to a unit that supports HDMI.
3.
LED Check
Click the [LED Check] button on the SERVICE MODE screen,
and the “LED CHECK” screen will appear.
and the “LED CHECK” screen will appear.
Using method:
LED ON or OFF can be controlled with [LED ON] or [LED OFF]
button on the screen.
LED ON or OFF can be controlled with [LED ON] or [LED OFF]
button on the screen.
6-41
HDR-SR5/SR5C/SR5E/SR7/SR7E/SR8/SR8E_ADJ
5.
Lens Barrier Check
Click the [Lens Barrier Check] button on the SERVICE MODE
screen, and the “LENS BARRIER CHECK” screen will appear.
screen, and the “LENS BARRIER CHECK” screen will appear.
Using method:
The lens barrier open or close can be controlled with [OPEN] or
[CLOSE] button on the screen.
The lens barrier open or close can be controlled with [OPEN] or
[CLOSE] button on the screen.
Ver. 1.1 2007.10
6.
G Sensor Check
Click the [G Sensor Check] button on the SERVICE MODE screen,
and the following screen will appear.
and the following screen will appear.
If the [Reset] button is clicked, the Camcorder is reset and it is
restarted, and then the “G SENSOR CHECK” screen will appear.
restarted, and then the “G SENSOR CHECK” screen will appear.
Using method:
Click the [Start] button, and the G sensor check will start.
During execution of G sensor check, the conditon of G sensor is
displayed.
Click the [Start] button, and the G sensor check will start.
During execution of G sensor check, the conditon of G sensor is
displayed.
Click the [Top] button, and the following message will be displayed.
If the [OK] button is clicked, and Camcorder is reset and it is re-
started, and then the SERVICE MODE screen will come back.
started, and then the SERVICE MODE screen will come back.
6-42
HDR-SR5/SR5C/SR5E/SR7/SR7E/SR8/SR8E_ADJ
8.
Shift Lens Check
Use the “Shift Lens Check” when the following self diagnostic
codes are displayed.
• E:62:10 [Shift Lens Initializing Failure]
codes are displayed.
• E:62:10 [Shift Lens Initializing Failure]
• E:62:11 [Shift Lens Overheating (Pitch)]
• E:62:12 [Shift Lens Overheating (Yaw)]
Click the [Shift Lens Check] button on the Service Mode screen,
and the “SHIFT LENS CHECK” screen will appear.
and the “SHIFT LENS CHECK” screen will appear.
[Check 1 using method]
Use this menu when E:62:10 (Shift Lens Initializing Failure) oc-
curred.
Click the [Check 1 Start] button, and the “EEPROM Check” and
“Steady Hall Adjustment” will be executed.
• When “Steady Hall Adjustment” is executed, the shift lens will
Use this menu when E:62:10 (Shift Lens Initializing Failure) oc-
curred.
Click the [Check 1 Start] button, and the “EEPROM Check” and
“Steady Hall Adjustment” will be executed.
• When “Steady Hall Adjustment” is executed, the shift lens will
move in up, down, left, and right directions. If the shift lens
does not move at all and a message “Shift Lens Check 1 Com-
plete” is displayed, or if an error message of Steady Hall Ad-
justment is displayed, replace the lens block.
does not move at all and a message “Shift Lens Check 1 Com-
plete” is displayed, or if an error message of Steady Hall Ad-
justment is displayed, replace the lens block.
• Check the peripheral circuits (particularly EEPROM (IC1804))
of the IC1803 on the VC-504 board, when the following mes-
sage is displayed.
sage is displayed.
[Check 2 using method]
Use this menu when E:62:11 (Shift Lens Overheating (Pitch)) oc-
curred.
Click the [Check 2 Start] button, and the shift lens will move in up
and down directions. If the shift lens does not move, replace the
lens block.
Use this menu when E:62:11 (Shift Lens Overheating (Pitch)) oc-
curred.
Click the [Check 2 Start] button, and the shift lens will move in up
and down directions. If the shift lens does not move, replace the
lens block.
[Check 3 using method]
Use this menu when E:62:12 (Shift Lens Overheating (Yaw)) oc-
curred.
Click the [Check 3 Start] button, and the shift lens will move in left
and right directions. If the shift lens does not move, replace the
lens block.
Use this menu when E:62:12 (Shift Lens Overheating (Yaw)) oc-
curred.
Click the [Check 3 Start] button, and the shift lens will move in left
and right directions. If the shift lens does not move, replace the
lens block.
7.
Record Data
Click the [Record Data] button on the SERVICE MODE screen,
and the “RECORD DATA” screen will appear.
and the “RECORD DATA” screen will appear.
The record data such as use record and self-diagnostic record are
displayed.
displayed.
Initializing method (Self-Diagnosis Data Only):
Click the [Clear Self-Diagnosis Data Only] button on the screen, and
the Self-Diagnosis Data will be initialized.
Click the [Clear Self-Diagnosis Data Only] button on the screen, and
the Self-Diagnosis Data will be initialized.
Note:
If a flash error (self-diagnosis code E:91:**) occurred, all
record data must be initialized to reset the error. The error
cannot be reset by initializing the self-diagnosis data only.
record data must be initialized to reset the error. The error
cannot be reset by initializing the self-diagnosis data only.
Initializing method (All Record-Data):
Click the [Clear All Recorded-Data] button on the screen, and the
All Recorded-Data will be initialized.
Click the [Clear All Recorded-Data] button on the screen, and the
All Recorded-Data will be initialized.
Note:
Performing the initialization causes all the user settings in-
cluding time setting to be initialized, too.
cluding time setting to be initialized, too.
Ver. 1.1 2007.10
6-43
HDR-SR5/SR5C/SR5E/SR7/SR7E/SR8/SR8E_ADJ
2-3.
DATA BACKUP
With the “DATA BACKUP”, the adjustment data in the camcorder
can be backed up in the PC as a file.
The adjustment data that can be backed up are as follows.
can be backed up in the PC as a file.
The adjustment data that can be backed up are as follows.
System Control Section:
1) Video System Adjustments
2) LCD/EVF System Adjustments
3) Audio System Adjustments
1) Video System Adjustments
2) LCD/EVF System Adjustments
3) Audio System Adjustments
Camera Control Section:
1) Camera System Adjustments
1) Camera System Adjustments
1.
Function of Each Button on Data Backup Screen
Click the [DATA BACKUP] button on the Main Menu screen, and
the “DATA BACKUP” screen in Fig. 6-2-3 will appear.
the “DATA BACKUP” screen in Fig. 6-2-3 will appear.
Fig. 6-2-3
1
[To Menu] button
The Main Menu screen comes back.
The Main Menu screen comes back.
2
[Data Read and Save] button
Read the adjustment data from the camcorder and save them
in PC as a file.
Read the adjustment data from the camcorder and save them
in PC as a file.
3
[Data Load and Write] button
Load the adjustment data from the file saved in PC and write
them to the camcorder.
Load the adjustment data from the file saved in PC and write
them to the camcorder.
1
2
3
2
3
Click on the first or last page to see other HDR-SR5 / HDR-SR5C / HDR-SR5E / HDR-SR7 / HDR-SR7E / HDR-SR8 / HDR-SR8E (serv.man4) service manuals if exist.