DOWNLOAD Sony HDR-SR5 / HDR-SR5C / HDR-SR5E / HDR-SR7 / HDR-SR7E / HDR-SR8 / HDR-SR8E (serv.man4) Service Manual ↓ Size: 959.21 KB | Pages: 49 in PDF or view online for FREE

Model
HDR-SR5 HDR-SR5C HDR-SR5E HDR-SR7 HDR-SR7E HDR-SR8 HDR-SR8E (serv.man4)
Pages
49
Size
959.21 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-sr5-hdr-sr5c-hdr-sr5e-hdr-sr7-hdr-sr7e-hdr-sr8.pdf
Date

Sony HDR-SR5 / HDR-SR5C / HDR-SR5E / HDR-SR7 / HDR-SR7E / HDR-SR8 / HDR-SR8E (serv.man4) Service Manual ▷ View online

6-36
HDR-SR5/SR5C/SR5E/SR7/SR7E/SR8/SR8E_ADJ
1-10. ERROR
In the case of an error during the execution of adjustment, the
Automatic Adjustment Program interrupts the processing at that
point, and displays an error message, and then terminates the pro-
gram execution there.
1-10-1. Error Message
When an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
though the remedy was performed, the circuits will be faulty.
1.
Connect Error, Adjust Control Error
Fig. 6-1-25
Symptom
USB communication with the set is abnormal.
Cause
• USB cable is not inserted tightly.
• Power supply is not installed correctly.
• Communication with SeusEX is abnormal.
Remedy
• Disconnect the USB cable once, and then re-
connect it tightly and check that the set is in
“USB Mode”.
• Install the power supply correctly.
• Start the SeusEX and click the [Connect] to
check that the connection state is established.
2.
RESET the CAMERA and Try Again
Fig. 6-1-26
Symptom
The camera is not ready for adjustment.
Cause
Data error exists in the camera.
Remedy
Reset the camera.
3.
Adjustment Time  Out
Fig. 6-1-27
Symptom
Adjustment does not finish within the specified
time.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
4.
Adjustment NG
Fig. 6-1-28
Symptom
The adjusted data does not become the speci-
fied value.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
This part indicates 
the adjustment 
item in which 
an error occurred.
This part indicates 
the adjustment 
item in which 
an error occurred.
6-37
HDR-SR5/SR5C/SR5E/SR7/SR7E/SR8/SR8E_ADJ
LCD System Adjustment screen
Fig. 6-1-31
Audio System Adjustment screen
Fig. 6-1-32
1-10-2. Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment
before the adjustment starts. Accordingly, if the adjustment termi-
nates by an error, the data during the adjustment may be left in the
camera.
Note:
With this data left in the camera, the camera will not oper-
ate normally.
In this case, the [Release Data Setting] button is displayed in “red”
on the screen as shown in Fig. 6-1-29 to Fig. 6-1-32. Click the
[Release Data Setting] button to cancel the data setting. When the
data setting is cancelled, the button color becomes “white”.
Video System Adjustment screen
Fig. 6-1-29
Camera System Adjustment screen
Fig. 6-1-30
6-38
HDR-SR5/SR5C/SR5E/SR7/SR7E/SR8/SR8E_ADJ
6-2. SERVICE  MODE
2-1.
APPLICATION FOR ADJUSTMENT (SeusEX)
The adjustment software (SeusEX) can change operational coeffi-
cients of signal processing, EVR data, etc. same as the adjustment
remote commander. The SeusEX performs two-way communica-
tion between PC and camcorder using the USB terminal. The two-
way communication result data can be written in the nonvolatile
memory.
1.
Connection
1) Connect the HASP key to the USB terminal of the PC.
2) Connect the PC and camcorder with the USB cable.
3) Start the SeusEX on the PC.
4) Click  [Connect]  on the SeusEX screen. If the connection is
normal, the SeusEX screen will be as shown in Fig. 6-2-1,
indicating the “connected” state.
Note:
The SeusEX will go in “disconnect” state, if the
camcorder is turned off (for instance, by resetting the
set). In such a case, click [Connect]  on the SeusEX
screen to restore the “connected” state.
Fig. 6-2-1
2.
Operation
• Block change
To  change the block, click [Block]  on the SeusEX screen and
enter the block to be changed. The block is displayed in hexa-
decimal notation.
• Page change
To change the page, click [Page] on the SeusEX screen and en-
ter the page to be changed. The page is displayed in hexadeci-
mal notation.
• Address change
To  change the address, click [Address]  on the SeusEX screen
and enter the address to be changed. The address is displayed in
hexadecimal notation.
• Data change
To change the data, click [Set] on the SeusEX screen and enter
the data. The data is displayed in hexadecimal notation.
This operation does not write the data to the nonvolatile memory.
• Data writing
To write the data to the EEPROM, click [Write] on the SeusEX
screen and enter the data value to be written.
To  write the data to the flash memory, change the data value
using the [Set] on the SeusEX screen and then click [Save] to
save the data.
• Data reading
The data displayed on the SeusEX screen are the data values at
the time when the pages and addresses were set, and they are
not updated automatically. To check the data change, click [Read]
on the SeusEX screen and update the displayed data.
6-39
HDR-SR5/SR5C/SR5E/SR7/SR7E/SR8/SR8E_ADJ
2.
Switch Check
Click the [Switch Check] button on the SERVICE MODE screen,
and the “SWITCH CHECK” screen will appear.
Using method:
Click the [Start] button, and the switch check will start.
During execution of switch check, the pressed switch is displayed
in orange. Also, once the switch was pressed, its name characters
change to blue in color.
2-2.
SERVICE  MODE
1.
Function of Each Button on Service Mode Screen
Click the [SERVICE MODE] button on the Main Menu screen, and
the “SERVICE MODE” screen in Fig. 6-2-2 will appear.
Fig. 6-2-2
1
[To Menu] button
The Main Menu screen comes back.
2
[Switch Check] button
“SWITCH CHECK” screen appears.
3
[LED Check] button
“LED CHECK” screen appears.
4
[Jack Check] button
“JACK CHECK” screen appears.
5
[Lens Barrier Check] button
“LENS BARRIER CHECK” screen appears.
6
[G Sensor Check] button
“G SENSOR CHECK” screen appears.
7
[Record Data] button
“RECORD DATA” screen appears.
8
[Shift Lens Check] button
“SHIFT LENS CHECK” screen appears.
1
5
2
3
4
6
7
8
Page of 49
Display

Click on the first or last page to see other HDR-SR5 / HDR-SR5C / HDR-SR5E / HDR-SR7 / HDR-SR7E / HDR-SR8 / HDR-SR8E (serv.man4) service manuals if exist.