1-6
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-CX500/CX500E/CX500V/CX500VE/CX505VE/
CX520/CX520E/CX520V/CX520VE_L2
1-4-3. E : 62 : 12 [Shift Lens Overheating (Yaw)] Occurred
Connect by the SeusEX and perform the following process.
Order Block Page Address Data
Procedure
1
11
80
7430
01
Write the data. (After it starts, set it before caution is displayed.)
2
11
8E
F656
01
Write the data.
3
11
8E
F657
F0
Write the data.
4
11
8E
F659
01
Write the data. (Note 1)
5
11
8E
F659
00
Write the data.
6
11
8E
F656
00
Write the data.
7
11
8E
F657
10
Write the data.
8
11
8E
F659
01
Write the data. (Note 1)
9
11
8E
F659
00
Write the data.
10
11
80
7430
00
Write the data.
11
Check if the shift lens moves while setting the order 2 to 9. If the shift lens does not move,
replace the lens block (Note 2). When the shift lens moved, proceed to the order 12.
12
While setting the order 2 to 9, measure with an oscilloscope the output voltage of R5524 in the
periphery of IC5501 on the VC-575 board to check the output voltage varies.
13
If the output voltage does not vary, replace the lens block (Note 2). When the output voltage
varied, proceed to the order 14.
14
Turn the power OFF.
While measuring with an oscilloscope the output voltage of R5653 land in the periphery of
15
IC5501 on the VC-575 board, turn the power ON to check that the output voltage immediately
after the power on change as shown in Fig. 2.
If the output voltage change as shown in Fig. 2, replace the lens block (Note 2). If it does not
16
change as shown in Fig. 2, inspect the camera control circuit (IC7501 of VC-575 board)
periphery.
Note 1: Finish this operation within 10 seconds. If it is likely to take more than 10 seconds, set block: 11, page: 8E, address:
F659, data: 00, and then retry.
Note 2: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment
items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
1-4-4. E : 62 : 20 [Abnormality of Thermistor] Occurred
Order
Procedure
1
Turn the power ON.
2
Confirm the connections of flexible flat cables and connectors between the lens block and VC-575 board.
3
In case of no malfunction of connections, replace the lens block with new one. (Note) When the error has occurred in spite of the
lens replacement, replace VC-575 board with new one.
Note: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment
items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
1-7
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-CX500/CX500E/CX500V/CX500VE/CX505VE/
CX520/CX520E/CX520V/CX520VE_L2
1-5. GPS RECEIVING CHECK (CX500V/CX500VE/CX505VE/CX520V/CX520VE)
After a part of set was replaced or after the set was assembled, check the reception of GPS signal.
How to check the GPS function
Bring your camcorder to an open area, and set the GPS switch to ON (
 appears on the LCD 
screen). Your camcorder starts trying to triangulate. When your camcorder triangulates 
successfully, it will record the location information at the time movies and photos were recorded. 
• The indicator changes according to the strength of GPS signal reception.
Triangulating status
GPS indicators
GPS reception status
Function off
No indicator
The GPS switch is set to OFF, or the GPS receiver is not 
functioning normally. 
Difficult
Your camcorder cannot find a GPS signal, therefore, it cannot 
triangulate. Use your camcorder in an open area.
Processing
Your camcorder is confirming the GPS signal, and will be able 
to acquire location information soon. Wait until your camcorder 
completes the triangulation.
Triangulating
Your camcorder is receiving a GPS signal, and can acquire location 
information.
Triangulating
Your camcorder is receiving a strong GPS signal, and can acquire 
location information.
• It may take from several seconds to several minutes to acquire the location information when you use the 
GPS for the first time or use it again after long intervals.
• You may not be able to acquire location information depending on the strength of GPS reception.
• When
 is displayed and it takes a while to triangulate, set the GPS switch to OFF, then set to ON again.
Notes
1-6. PRECAUTION  ON  REPLACING  THE  MM-083 BOARD
Do not factory check MM-083 board in which Map Data is installed (CX500V/CX500VE/CX505VE/CX520V/CX520VE).
The map data is erased when the factory check is done.
Angular Velocity Sensor
When you replace to the reparing board, write down the sensitivity displayed on the angular velocity sensor (SE6601).
Start the Adjust Manual in the Adjust Station and execute the “GYRO sensor sensitivity adj”.
Note:
The sensor sensitivity of SE6601 of MM-083 board is written only repair parts.
SE6601
PPP
YYY
MM-083 BOARD (SIDE B)
PPP:
PITCH sensor sensitivity 
t
 G
1
YYY:
YAW sensor sensitivity 
t
 G
2
1-8
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-CX500/CX500E/CX500V/CX500VE/CX505VE/
CX520/CX520E/CX520V/CX520VE_L2
1. SERVICE NOTE
1-1. 修理時の電源供給について
本機では,安定化電源(8.4Vdc)からバッテリ端子に電源を供給した場合,約10秒後にシャットオフし,動作しなくなります。
これを避けるため,下記の方法を用いてください。
方法:
ACアダプタ(AC-L200C/L200D)を使用する。
1-2. VC-575基板交換時の注意
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を実行させてください。
仕向けデータ設定
補修用基板交換後、電源を入れると内蔵記録メディアエラーが表示される場合がありますが、「D E S T I N A T I O N   D A T A
WRITE」を実行させると消えます。「DESTINATION  DATA  WRITE」実行しても消えない場合は、内蔵記録メディアを
フォーマットしてください。
USBシリアルセーブ
補修用基板と交換する時,交換前の基板よりUSBシリアルNo.を取得してください。
データの取得はAdjust StationからAdjust Manualを起動させて「USB SERIAL SAVE」を実行させてください。
USBシリアルNo.
セットは,1台毎に異なる固有のID(USB Serial No.)を書き込んだ後,出荷されています。
新品の補修用基板には,このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
Adjust StationからAdjust Manualを起動させて「USB serial No. input」を実行させてください。
Ver. 1.1  2009.12
Ver.1.0からの変更部分は
青色で記載されています。
1-9
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-CX500/CX500E/CX500V/CX500VE/CX505VE/
CX520/CX520E/CX520V/CX520VE_L2
症状/状態
標準以外のバッテリを使用している
バッテリが高温になっている
フォーマットしていない“メモリー
ステック デュオ”を入れた
“メモリーステック デュオ”が壊
れている
アクセスエラー
フォーカスが合いにくい
(フォーカスの初期化ができない)
フラッシュメモリが書き換えられている
ズーム動作の異常(ズームレンズの
初期化ができない)
フォーカス,ズーム異常
C
C
C
C
C
E
E
E
ブロック
機能
0
4
0
6
1
3
1
3
3
2
2
0
6
1
6
1
詳細
コード
0
0
0
0
0
1
0
2
6
0
0
0
1
0
1
1
自己診断コード
1-3. 自己診断機能
1-3-1. 自己診断機能について
本機の動作に不具合が生じたとき,自己診断機能が働き,
L C D 画面に,どう処置したらよいか判断できる表示を行い
ます。「自己診断表示」と「サービスモード表示」の2つの表
示があります。自己診断機能については取扱説明書にも掲載
されています。
1-3-2. 自己診断表示
本機の動作に不具合が生じたとき,LCD画面のカウンタ表示
部分がアルファベットと数字の4 桁表示になり,3 . 2 H z で点
滅します。この5 文字の表示によって対応者分類および不具
合の生じたブロックの分類,不具合の詳細コードを示しま
す。
1 1
3 1
C
対応者分類 
「1 -3 -3 .  自己診断コード表」 
を参照 
対応方法の違いにより分類 
例 
 
31 ・・ ・テープを入れ直す 
 
 
32 ・・ ・電源を入れ直す 
ブロック分類 
詳細コード 
3.2Hz点滅 
C  :お客さま自身で対応 
H  :販売店で対応 
E  :サービスエンジニア 
 
で対応 
LCD画面 
C : 3 1 : 1 1
1-3-3. 自己診断コード表
注意1:Adjust StationからAdjust Manualを起動させて,「 Destination data write 」を参照してください。
対応/方法
インフォリチウムバッテリを使用する。
バッテリを交換するか,バッテリを涼しいところに置く。
“メモリーステック デュオ”をフォーマットする。
新しい“メモリーステック デュオ”に交換する。
電源を外し,再度入れ直してから操作する。
操作スイッチの電源を入れ直す。
復帰しない場合,レンズブロックのフォーカスMRセンサ
(VC-575基板CN1010 e;,eaピン)を点検する。異常なけ
ればフォーカスモータ駆動回路(VC-575基板IC5201)を点
検する。
フラッシュメモリのデータを元の値に戻す。(注意1)
 ズームレバーを操作したときにズーム動作をすれば,レン
ズブロックのズームMRセンサ(VC-575基板CN1010ef,eg
ピン)を点検する。ズーム動作をしなければズームモータ
駆動回路(VC-575基板IC5201)を点検する。
自己診断コードC:32:60とE:61:10の両方を点検する。