DOWNLOAD Sony DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man4) Service Manual ↓ Size: 1.28 MB | Pages: 72 in PDF or view online for FREE

Model
DCR-TRV60 DCR-TRV60E DCR-TRV70 (serv.man4)
Pages
72
Size
1.28 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv60-dcr-trv60e-dcr-trv70-sm4.pdf
Date

Sony DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man4) Service Manual ▷ View online

6-22
DCR-TRV60/TRV60E/TRV70
6. 1F Page Table
Note1:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Table. 6-1-13.
Address
Remark
00
01 to 35
36
37
38
39 to 3D
3E
3F to 44
45
46
47 to 57
58
59 to 5B
5C
5D to 6F
70
71
72 to 7A
7B
7C to 8D
8E
8F to 93
94
95
96
97
98
99 to AB
AC
AD
AE
AF
B0
B1
B2
B3 to B9
BA
BB
BC to C9
CA
CB
CC
CD
CE to E4
E5
E6 to  F2
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
F3
F4 to FC
FD
FE to FF
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
6-23
DCR-TRV60/TRV60E/TRV70
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for “54MHz/
67.5MHz Origin Oscillation Adjustment”), check that the specified
values of “VIDEO SYSTEM ADJUSTMENTS” are satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
[Data Setting during Camera System Adjustments]
When performing the adjustments from “8. Flange Back
Adjustment” to “23. AF Laser Axis Check (2)”. Some data settings
are necessary. (Refer to “6. Flange Back Adjustment (Using
Minipattern Box)”.)
1. 54MHz/67.5MHz Origin Oscillation Adjustment
(CD-433 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin <zc.> of IC2101 on VC-314 board
(R2132)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified Value
f=13500000 ± 68Hz
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
10
Change the data and set the
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Set the data.
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
13 to 18, 92
Specified Value 1
D6 to DA
Specified Value 2
26 to 2A
Specified Value 3
D3 to DD
Specified Value 4
23 to 2D
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
POWER ......................................................................... CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
6D
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note3)
4
6
01
00
Set the data, and press PAUSE
button.
Note3:
The adjustment data will be automatically input to page: F, address:
13 to 18, 92.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
6
01
03
Set the data, and press PAUSE
button.
4
1
Check that the IRIS display data
(Note1) satisfies the specified value 1.
5
6
01
01
Set the data, and press PAUSE
button.
6
1
Check that the IRIS display data
(Note1) satisfies the specified value.2.
7
6
01
6B
Set the data, and press PAUSE
button.
8
6
01
69
Set the data, and press PAUSE
button.
9
1
Check that the ND display data
(Note1) satisfies the specified value 3.
10
6
01
6B
Set the data, and press PAUSE
button.
11
1
Check that the ND display data
(Note1) satisfies the specified value 4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
03
00
Set the data.
3
0
01
00
Set the data.
COVER
COVER
Fig. 6-1-9.
IC2101
R2132 
VC-314 board
6-24
DCR-TRV60/TRV60E/TRV70
3. MR Adjustment
The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
58, 5A to 65
Specified Value1
40 to C0
Specified Value2
03 to 70
Specified Value3
90 to FD
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
Perform this adjustment before “Flange Back Adjustment”.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
BD
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note5)
4
F
5A
Check that the data satisfies the
specified value 1.
5
F
5B
Check that the data satisfies the
specified value 1.
6
F
5C
Check that the data satisfies the
specified value 1.
7
F
5D
Check that the data satisfies the
specified value 1.
8
F
5E
Check that the data satisfies the
specified value 2.
9
F
5F
Check that the data satisfies the
specified value 3.
10
F
60
Check that the data satisfies the
specified value 2.
11
F
61
Check that the data satisfies the
specified value 3.
12
F
62
Check that the data satisfies the
specified value 2.
13
F
63
Check that the data satisfies the
specified value 3.
14
F
64
Check that the data satisfies the
specified value 2.
15
F
65
Check that the data satisfies the
specified value 3.
Note5:
The adjustment data will be automatically input to page: F, address:
58, 5A to 65.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again
6-25
DCR-TRV60/TRV60E/TRV70
4. CCD Output 2ch Matching Adjustment (1)
Correct the dispersion of the black level between the left-right
channels of the CCD imager.
Subject
Arbitrary
Adjustment Page
F
Adjustment Address
24 to 27
Note1:
This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
F3
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
24 to 27.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
Perform “CCD Output 2ch
Matching Adjustment (2)”.
5. CCD Output 2ch Matching Adjustment (2)
Correct the dispersion between the left-right channels of the CCD
imager.
Subject
Clear chart (All white) (Note1)
Adjustment Page
F
Adjustment Address
29 to 2D
Note1:
Shoot the clear chart with the zoom TELE end.
Note2:
This adjustment should be carried out upon completion of the
following adjustments.
CCD Output 2ch Matching adjustment (1)
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
2C
01
Set the data.
3
6
40
01
Set the data.
4
6
01
F5
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“00” in about 50 seconds after
pressing PAUSE button.
Note5:
The adjustment data will be automatically input to page: F, address:
29 to 2D
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
2C
00
Set the data.
3
6
40
00
Set the data.
4
0
01
00
Set the data.
Page of 72
Display

Click on the first or last page to see other DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man4) service manuals if exist.