DOWNLOAD Sony DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man4) Service Manual ↓ Size: 1.28 MB | Pages: 72 in PDF or view online for FREE

Model
DCR-TRV60 DCR-TRV60E DCR-TRV70 (serv.man4)
Pages
72
Size
1.28 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv60-dcr-trv60e-dcr-trv70-sm4.pdf
Date

Sony DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man4) Service Manual ▷ View online

6-38
DCR-TRV60/TRV60E/TRV70
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
E
EF
00
Set the data.
2
6
23
00
Set the data.
3
6
5B
00
Set the data.
4
6
5C
00
Set the data.
5
6
90
00
Set the data.
6
6
91
00
Set the data.
7
6
92
00
Set the data.
8
6
93
00
Set the data.
9
6
01
00
Set the data, and press PAUSE
button.
10
0
01
00
Set the data.
Fig. 6-1-14.
Inspection frame
22. AF Laser Axis Check (1)
Subject
Dark homogeneous subject
(1m from the front of the lens)
(Note1)
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
Monitor TV (Under scan mode)
Specified Value
Two or more hologram lines are
perfectly within the inspection frame.
(Fig. 6-1-14.)
The hologram lines can be seen at
every outside of the inspection frame.
Note1:
Background paper (J-250-130-A) etc. Perform this adjustment in
the dark place.
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER ................................................................. MEMORY
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
Checking method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
E
EF
82
Set the data.
3
6
23
04
Set the data.
4
6
5B
B4
Set the data.
5
6
5C
B4
Set the data.
6
6
66
00
Set the data.
7
6
67
00
Set the data.
8
6
90
DB
Set the data.
9
6
91
02
Set the data.
10
6
92
C0
Set the data.
11
6
93
46
Set the data.
12
6
01
79
Set the data, and press PAUSE
button.
13
6
01
78
Set the data, and press PAUSE
button.
14
Check that two or more
hologram lines are perfectly
within the inspection frame.
(Fig. 6-1-14.)
15
Check that the hologram lines
can be seen at every outside of
the inspection frame on the
monitor TV screen (the top, the
bottom, the left and the right).
(Fig. 6-1-14.)
6-39
DCR-TRV60/TRV60E/TRV70
23. AF Laser Axis Check (2)
Subject
Dark homogeneous subject
(50cm from the front of the lens)
(Note1)
Measurement Point
Video terminal of AUDIO/VIDEO
jack
Measuring Instrument
Monitor TV (Under scan mode)
Specified Value
Two or more hologram lines are
perfectly within the inspection frame.
(Fig. 6-1-15.)
The hologram lines can be seen at
every outside of the inspection frame.
Note1:
Background paper (J-250-130-A) etc. Perform this adjustment in
the dark place.
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER ................................................................. MEMORY
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
Checking method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
E
EF
82
Set the data.
3
6
23
04
Set the data.
4
6
5B
A6
Set the data.
5
6
5C
A6
Set the data.
6
6
66
07
Set the data.
7
6
67
08
Set the data.
8
6
90
AB
Set the data.
9
6
91
01
Set the data.
10
6
92
F0
Set the data.
11
6
93
57
Set the data.
12
6
01
79
Set the data, and press PAUSE
button.
13
6
01
78
Set the data, and press PAUSE
button.
14
Check that two or more
hologram lines are perfectly
within the inspection frame.
(Fig. 6-1-15.)
15
Check that the hologram lines
can be seen at every outside of
the inspection frame on the
monitor TV screen (the top, the
bottom, the left and the right).
(Fig. 6-1-15.)
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
E
EF
00
Set the data.
2
6
23
00
Set the data.
3
6
5B
00
Set the data.
4
6
5C
00
Set the data.
5
6
66
00
Set the data.
6
6
67
00
Set the data.
7
6
90
00
Set the data.
8
6
91
00
Set the data.
9
6
92
00
Set the data.
10
6
93
00
Set the data.
11
6
01
00
Set the data, and press PAUSE
button.
12
0
01
00
Set the data.
Fig. 6-1-15.
Inspection frame
6-40
DCR-TRV60/TRV60E/TRV70
COVER
COVER
1-4.
COLOR ELECTRONIC VIEWFINDER
SYSTEM ADJUSTMENT
Note1:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note3:
As the PANEL CLOSE switch is attached to the cabinet (R), this
cabinet must be attached when performing adjustments.
If you perform the adjustments with cabinet (R) removed, set the
following data.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
Note4:
NTSC model: DCR-TRV60/TRV70
PAL model: DCR-TRV60E
Switch setting:
LCD panel ........................................................................... Closed
[Measuring points]
The measuring points for manual adjustments are CL3201 (VG (Pin
4
 of CN3201)) and CL3202 (HDO (Pin 2 of IC3202)) of DI-088
board.
1. VCO Adjustment (DI-088 board)
Set the VCO free-run frequency. If deviated, the EVF screen will be
blurred.
Note:
Do either of the automatic adjustment or the manual adjustment.
1-1. Manual Adjustment
Mode
Camera
Subject
Arbitrary
Measurement Point
CL3202 (HDO (Pin 2 of IC3202))
Measuring Instrument
Frequency counter
Adjustment Page
C
Adjustment Address
36, 37
Specified Value
f = 15734 ± 30Hz (NTSC)
f = 15625 ± 30Hz (PAL)
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
36
Change the data and set the VCO
frequency (f) to the specified value.
3
C
36
Press PAUSE button.
4
C
36
Read the data, and this data is
named D
36
.
5
Convert D
36
 to decimal notation,
and obtain D
36
’. (Note2)
6
Calculate D
37
’ using following
equations (Decimal calculation)
[NTSC model]
When D
36
’   231
D
37
’=D
36
’ + 24
When D
36
’ > 231
D
37
’ = 255
[PAL model]
When D
36
’   24
D
37
’=D
36
’ – 24
When D
36
’ < 24
D
37
’ = 0
7
Convert D
37
’ to a hexadecimal
number, and obtain D
37
. (Note2)
8
C
37
D
37
Set the data, and press PAUSE
button.
9
0
01
00
Set the data.
Note2:
Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
Fig 6-1-16.
Caution:
High
voltage
DI-088 board
CL3202
(HDO)
CL3201
(VG)
CN3201
1
16
6-41
DCR-TRV60/TRV60E/TRV70
1-2. Automatic Adjustment
Mode
Camera
Subject
Arbitrary
Measurement Point
Check on EVF screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
36, 37
Specified Value
The EVF screen should be stable.
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
20
Set the data, and press PAUSE
button.
3
3
22
0F
Set the data, and press PAUSE
button.
4
C
5A
73
Set the data, and press PAUSE
button.
5
C
36
Set the following data, and press
PAUSE button.
59 (NTSC), 78 (PAL)
6
C
36
Read the data, and this data is
named PRESET DATA.
7
C
36
Add 30 (Hexadecimal) to the
data and press PAUSE button.
8
C
36
Check the EVF screen.
When the screen is stable,
proceed to step 12.
When the screen is unstable,
proceed to step 9.
9
Using Table 6-1-14 or Table 6-1-
16, read the new PRESET DATA
corresponding to the PRESET
DATA.
10
C
36
Set the new PRESET DATA and
press PAUSE button.
11
Return to step 6.
12
C
36
Set the PRESET DATA and
press PAUSE button.
13
C
36
Subtract 30 (Hexadecimal) from
the data and press PAUSE button.
14
C
36
Check the EVF screen.
When the screen is stable,
proceed to step 18.
When the screen is unstable,
proceed to step 15.
15
Using Table 6-1-15 or Table 6-1-
17, read the new PRESET DATA
corresponding to the PRESET
DATA.
16
C
36
Set the new PRESET DATA and
press PAUSE button.
17
Return to step 6.
18
C
36
Set the PRESET DATA and
press PAUSE button.
19
C
36
Read the data, and this data is
named D
36
.
Order Page Address Data
Procedure
20
Convert D
36
 to decimal notation,
and obtain D
36
’. (Note2)
21
Calculate D
37
’ using following
equations (Decimal calculation)
[NTSC model]
When D
36
’   231
D
37
’ =D
36
’ + 24
When D
36
’ >231
D
37
’ =255
[PAL model]
When D
36
’  24
D
37
’ = D
36
’ – 24
When D
36
’ < 24
D
37
’ = 0
22
Convert D
37
’ to a hexadecimal
number, and obtain D
37.
 (Note2)
23
C
37
D
37
Set the data, and press PAUSE
button.
24
C
5A
F3
Set the data, and press PAUSE
button.
25
3
0C
00
Set the data, and press PAUSE
button.
26
3
22
00
Set the data.
27
0
01
00
Set the data.
Note2:
Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
PRESET DATA
59
41
29
New PRESET DATA
41
29
11
PRESET DATA
59
71
89
A1
New PRESET DATA
71
89
A1
B9
Table 6-1-14.
PRESET DATA
78
60
48
New PRESET DATA
60
48
30
Table 6-1-15.
Table 6-1-16.
PRESET DATA
78
90
A8
C0
D8
Table 6-1-17.
New PRESET DATA
90
A8
C0
D8
F0
PRESET DATA for NTSC model
PRESET DATA for PAL model
Page of 72
Display