DOWNLOAD Sony DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man4) Service Manual ↓ Size: 1.28 MB | Pages: 72 in PDF or view online for FREE

Model
DCR-TRV60 DCR-TRV60E DCR-TRV70 (serv.man4)
Pages
72
Size
1.28 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv60-dcr-trv60e-dcr-trv70-sm4.pdf
Date

Sony DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man4) Service Manual ▷ View online

6-26
DCR-TRV60/TRV60E/TRV70
6. Flange Back Adjustment
(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
the minipattern box (Note1)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
48 to 58
Specified Value
Data of page: F, address: 57 is “00” to
“09”.
Note1:
Dark Siemens star chart.
Note2:
This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”, “MR Adjustment”
“CCD Output 2ch Matching Adjustment”
Note3:
Make the lens horizontal and perform this adjustment.
Note4:
The data of page: 0, address: 10 must be “00”.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
COLOR SLOW SHUTTER (Function setting) ............... OFF
Preparations:
1)
The minipattern box is installed as shown in the following
figure.
Note: The attachment lenses are not used.
2)
Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3cm.
3)
Make the height of the minipattern box and the camcorder equal.
4)
Check that the output voltage of the regulated power supply is
the specified voltage.
5)
Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the
minipattern box.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button. (Note3)
3
6
01
27
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note6)
5
F
57
Check the data is “00” to “09”.
Note6:
The adjustment data will be automatically input to page: F, address:
48 to 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
01
25
Set the data, and press PAUSE
button.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
5
Perform “Data Setting during
the Following Camera System
Adjustments”.
6
Perform “Flange Back Check”.
[Data Setting during the Following Camera System Adjustments]
Before performing the adjustments from “8. Flange Back Check”
to “23. AF Laser Axis Check (2)”. Perform the following data setting.
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 0, address: 10, and set data: 01.
3)
Select page: E, address: 92, set data: 11 and press the PAUSE
button.
4)
Select page: 0, address: 10, and set data: 01.
[Release of the Data Setting]
After completing the camera system adjustments, release the data
setting.
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 0, address: 10, and set data: 01.
3)
Select page: E, address: 92, set data: 13 and press the PAUSE
button.
4)
Select page: 0, address: 10, and set data: 01.
5)
Select page: 0, address: 01, and set data: 00.
Fig. 6-1-10.
Minipattern box
Below 3 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01Vdc
Output current : more than 3.5A
6-27
DCR-TRV60/TRV60E/TRV70
7. Flange Back Adjustment (Using Flange Back
Adjustment Chart and Subject More Than 500m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
7-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass) (Luminance: 350 ± 50 lux)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
48 to 58
Specified Value
Data of page: F, address: 57 is “00” to
“09”.
Note1:
This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”, “MR Adjustment”
“CCD Output 2ch Matching Adjustment”
Note2:
Make the lens horizontal and perform this adjustment.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
COLOR SLOW SHUTTER (Function setting) ............... OFF
Preparations:
1)
Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button. (Note2)
3
6
01
15
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note5)
5
F
57
Check the data is “00” to “09”.
Note5:
The adjustment data will be automatically input to page: F, address:
48 to 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
01
25
Set the data, and press PAUSE
button.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
5
Perform “Flange Back
Adjustment (2)”
7-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
48 to 58
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
COLOR SLOW SHUTTER (Function setting) ............... OFF
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button. (Note2)
3
Place a ND filter on the lens so
that the optimum image is obtain.
4
6
01
29
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
48 to 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
01
25
Set the data, and press PAUSE
button.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
5
Perform “Data Setting during
the Following Camera System
Adjustments”. (Note5)
6
Perform “Flange Back Check”
Note5:
Refer to “6. Flange Back Adjustment (Using Minipattern Box)”.
6-28
DCR-TRV60/TRV60E/TRV70
8. Flange Back Check
Subject
Siemens star
(2.0m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE
end.
Note1:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT ............................................................................. OFF
Note2:
When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page 1 of the adjustment remote
commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
1)
Select page: 6, address: 40, and set data: 01.
2)
Select page: 6, address: 41, and set data: 01.
3)
Place the Siemens star 2.0m from the front of the lens.
4)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
5)
Shoot the Siemens star with the zoom TELE end.
6)
Turn on the auto focus.
7)
Check that the lens is focused (Note2).
8)
Select page: 6, address: 21, and set data: 10.
9)
Shoot the Siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1)
Select page: 6, address: 21, and set data: 00.
2)
Select page: 6, address: 40, and set data: 00.
3)
Select page: 6, address: 41, and set data: 00.
4)
Select page: 0, address: 03, and set data: 00.
9. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart (Approx. 1m from the
front of the lens) Note1
Adjustment Page
F
Adjustment Address
19
Note1:
Shoot the clear chart with the zoom WIDE end. And adjust the
direction of the camera so that the chart is located in the center of
the screen.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
This adjustment should be carried out upon completion of “Flange
Back Adjustment”.
Note4:
NTSC model: DCR-TRV60/TRV70
PAL model: DCR-TRV60E
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
ZOOM .................................................................... WIDE end
4)
DIGITAL ZOOM (Menu setting) .................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
2C
01
Set the data.
3
6
40
01
Set the data.
4
6
96
Set the following data.
24 (NTSC), 27 (PAL)
5
6
97
00
Set the data.
6
6
01
6F
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note5)
Note5:
 The adjustment data will be automatically input to page: F, address:
19.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
2C
00
Set the data.
2
6
40
00
Set the data.
3
6
96
00
Set the data.
4
6
97
00
Set the data.
5
6
01
00
Set the data, and press PAUSE
button.
6
0
01
00
Set the data.
6-29
DCR-TRV60/TRV60E/TRV70
10. Picture Frame Setting
(Color Reproduction Adjustment Frame)
When performing “Color Reproduction Adjustment” and “LV
Standard Data Input”, set the picture frame to “Color reproduction
adjustment frame”.
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.5m from the front of the lens)
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
Oscilloscope,
TV monitor (Under scan mode)
Specified Value
A=B, C=D, E=F
Note1:
The following adjustments should be carried out upon completion
of “Flange Back Adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (Menu setting) .................................... OFF
5)
STEADY SHOT (Menu setting) ...................................... OFF
Setting method:
1)
Adjust the zoom and the camera direction, and set to the
specified position.
2)
Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color reproduction adjustment frame”.
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-11.
2. Vertical period
Fig. 6-1-12.
Check on the monitor TV (Underscanned mode)
Fig. 6-1-13.
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
Page of 72
Display

Click on the first or last page to see other DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man4) service manuals if exist.