DOWNLOAD Sony DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man4) Service Manual ↓ Size: 1.28 MB | Pages: 72 in PDF or view online for FREE

Model
DCR-TRV60 DCR-TRV60E DCR-TRV70 (serv.man4)
Pages
72
Size
1.28 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv60-dcr-trv60e-dcr-trv70-sm4.pdf
Date

Sony DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man4) Service Manual ▷ View online

6-14
DCR-TRV60/TRV60E/TRV70
1-2-3. INITIALIZATION OF 8, C, 18, 1C PAGE DATA
Note:
When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 18, 1C page data, select page: 0, address:
10, and set data: 01, then select 8 or C page. The 18 or 1C page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 18, 1C Page Data
Note1:
If “Initializing the 8, C, 18, 1C Page Data” is performed, all data
of the 8 page, C page, 18 page and 1C page will be initialized. (It
is impossible to initialize a single page.)
Note2:
 If the 8, C, 18, 1C page data has been initialized, following
adjustments need to be performed again.
1) Modification of 8, C, 18, 1C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Serial No. input
5) Servo and RF system adjustments
6) Video system adjustments
Note3:
The power supply voltage must be 6.3 ± 0.1Vdc.
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
18
Adjusting Address
00 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C,
18, 1C Page Data”.
2. Modification of 8, C, 18, 1C Page Data
If the 8, C, 18, 1C page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 18, 1C page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 18, 1C page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 18, 1C Page
data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
6-15
DCR-TRV60/TRV60E/TRV70
3. 8 Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Table. 6-1-6.
Address
Remark
00 to 18
19
1A to 29
2A
2B to 34
34
35 to 3F
40
41 to 79
7A
7B
7C
7D to 81
82
83
84
85 to 86
87
88
89
8A
8B
8C to 91
92
93 to 94
95
96 to AC
AD
AE to B0
B1
B2 to B5
B6
B7
B8
B9
BA
BB
BC to BD
BE
BF
C0 to C3
C4
C5
C6 to C7
C8
C9
CA
CB
CC
CD
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Address
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
CE to D5
D6
D7
D8
D9 to DA
DB
DC
DD
DE
DF
E0
E1 to E2
E3
E4
E5
E6
E7
E8
E9 to EA
EB
EC
ED
EE
EF to FF
6-16
DCR-TRV60/TRV60E/TRV70
4. C Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Table. 6-1-7.
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10
11
12
13
14 to 15
16
17 to 24
25
26
27
28 to 33
34
35
36
37
38
39
3A to 3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
EE
00
00
00
E0
5D
7D
59
59
71
8A
8D
73
35
6A
93
A2
A3
7D
65
40
C0
EE
00
00
00
E0
5D
7D
59
78
60
87
8D
73
35
6A
93
A2
A3
7D
65
40
C0
Switching position adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Fixed data-1
Fixed data-2
VCO adj. (EVF)
Fixed data-2
RGB AMP adj. (EVF)
Fixed data-1
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
VCO adj. (LCD)
V COM adj. (LCD)
RGB AMP adj. (LCD)
Fixed data-2
White balance adj. (LCD)
Contrast adj. (LCD)
Fixed data-2
PSIG black adj. (LCD)
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Address
Remark
Initial value
Initial value
NTSC PAL
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E to 9B
9C
9D to A3
A4
A5 to CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5 to DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Serial No. input
Fixed data-1
Emergency memory address
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
6-17
DCR-TRV60/TRV60E/TRV70
5. 18 Page Table
Note1:
When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Table. 6-1-8.
6. 1C Page Table
Note1:
When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modfied data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Address
Remark
00
01
02 to C4
C5
C6 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-9.
00 to B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9 to FF
00
00
00
00
00
80
00
00
00
00
00
00
00
00
00
00
80
00
00
00
00
00
Fixed data-1
Error rate check
Fixed data-1
Address
Remark
Initial value
Page of 72
Display

Click on the first or last page to see other DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man4) service manuals if exist.