81
Editing
Dubbing only desired scenes – Digital program editing (on a tape)
Step 2: Setting the VCR for operation
When connecting with the A/V connecting cable, your camcorder sends the control
signal by infrared rays to the remote sensor on the VCR.
signal by infrared rays to the remote sensor on the VCR.
The POWER switch should be set to
.
Operate by touching the panel.
(1)
Turn the power of the connected VCR on.
If your VCR has an input selector, set it to the input mode. When you connect
a video camera recorder, set its power switch to VCR/VTR.
If your VCR has an input selector, set it to the input mode. When you connect
a video camera recorder, set its power switch to VCR/VTR.
(2)
Press FN to display PAGE1.
(3)
Press MENU.
(4)
Select VIDEO EDIT in
, then press EXEC.
(5)
Select TAPE, then press EXEC.
(6)
Press EDIT SET.
(7)
Select CONTROL, then press EXEC.
(8)
When connecting with the A/V connecting cable, select IR, then press EXEC.
When connecting with the i.LINK cable, select i.LINK, press EXEC, then go to
“Step 3: Adjusting the synchronization of the VCR” on page 84.
When connecting with the i.LINK cable, select i.LINK, press EXEC, then go to
“Step 3: Adjusting the synchronization of the VCR” on page 84.
(9)
Select IR SETUP, then press EXEC.
(10) Select the IR SETUP code of your VCR, then press EXEC. Check the code in
“About the IR SETUP code” (p. 83).
4
5
7
9
6
V I DEO ED I T
ED I T SET
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
END
RET.
EXEC
I R
V I DEO ED I T
ED I T SET
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
RET.
EXEC
3
V I DEO ED I T
ED I T SET
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
RET.
EXEC
I R
i. L I NK
i. L I NK
END
0:32:30:14
TOTAL
SCENE
SCENE
0:00:00:00
0
0
V I DEO ED I T
MARK
I N
I N
START
ED I T
SET
SET
UNDO
END
OTHERS
DATA CODE
BEEP
COMMANDER
D I SPL AY
V I DEO ED I T
BEEP
COMMANDER
D I SPL AY
V I DEO ED I T
EXIT
RET.
EXEC
RETURN
TAPE
MEMORY
TAPE
MEMORY
END
(continued on the following page)
82
(11) Select PAUSEMODE, then press EXEC.
(12) Select the mode to cancel recording pause on the VCR, then press EXEC.
(12) Select the mode to cancel recording pause on the VCR, then press EXEC.
The correct button depends on your VCR.
Refer to the operating instructions of your VCR.
Refer to the operating instructions of your VCR.
(13) Locate the infrared rays emitter of your camcorder and face it towards the
remote sensor of the VCR about 30 cm (12 in.) apart.
Do not put any obstacles between the both equipment.
Do not put any obstacles between the both equipment.
(14) Insert a recordable tape into the VCR, then set the VCR to recording
pause.
(15) Select IR TEST, then press EXEC.
(16) Select EXECUTE, then press EXEC.
(16) Select EXECUTE, then press EXEC.
If the VCR starts recording, the setting is correct.
The indicator you selected to cancel recording pause on the VCR flashes
on the screen. When finished, the indicator changes to COMPLETE.
The indicator you selected to cancel recording pause on the VCR flashes
on the screen. When finished, the indicator changes to COMPLETE.
Dubbing only desired scenes – Digital program editing (on a tape)
V I DEO ED I T
ED I T SET
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
RET.
EXEC
PAUSE
END
V I DEO ED I T
ED I T SET
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
RET.
EXEC
PAUSE
REC
PB
REC
PB
END
11
12
VCR
Remote sensor
Infrared rays emitter
15
16
V I DEO ED I T
ED I T SET
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
RET.
EXEC
ENGAGE
REC PAUSE
REC PAUSE
RETURN
EXECUTE
EXECUTE
V I DEO ED I T
ED I T SET
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
CONTROL
ADJ TEST
”CUT - I N”
”CUT -OUT”
I R SETUP
PAUSEMODE
I R TEST
RET.
EXEC
COMPLETE
END
END
83
Editing
When the VCR does not operate correctly
•After checking the code in “About the IR SETUP code,” set the IR SETUP or the
•After checking the code in “About the IR SETUP code,” set the IR SETUP or the
PAUSEMODE again.
•Place your camcorder at least 30 cm (12 in.) away from the VCR.
•Refer to the operating instructions of your VCR.
Note
When you connect with the i.LINK cable, you may not be able to operate the dubbing
function correctly, depending on the VCR.
Set CONTROL to IR in the menu settings of your camcorder.
•Refer to the operating instructions of your VCR.
Note
When you connect with the i.LINK cable, you may not be able to operate the dubbing
function correctly, depending on the VCR.
Set CONTROL to IR in the menu settings of your camcorder.
About the IR SETUP code
The IR SETUP code is stored in the memory of your camcorder. Be sure to set the
correct code, depending on your VCR. Default setting is code number 3.
correct code, depending on your VCR. Default setting is code number 3.
Note on the IR SETUP code
Digital program editing is not possible if the VCR does not support IR SETUP codes.
Digital program editing is not possible if the VCR does not support IR SETUP codes.
Dubbing only desired scenes – Digital program editing (on a tape)
Brand
IR SETUP code
Sony
1, 2, 3, 4, 5, 6
Admiral (M. Wards)
89
Aiwa
47, 54, 80
Akai
49, 51
Audio Dynamic
21, 35
Bell&Howell
36
(M. Wards)
Broksonic
21, 70, 82
Canon
77, 78
Citizen
47
Craig
47, 73
Curtis Mathis
8, 77, 80
Daewoo
26, 40, 77
DBX
21, 33, 35
Dimensia
8
Emerson
26, 48, 59, 70, 80, 81, 82
Fisher
36, 37, 44, 45
Funai
80
General Electric
8, 32*, 77, 94*, 101
Goldstar/LG
47
GO VIDEO
71
Hitachi
8, 42, 78
HQ
40
Instant Replay
77, 78
JC Penny
8, 21, 33, 35, 36, 42, 77
JVC
12, 13, 14, 21, 33, 35
Kenwood
21, 33, 35, 47
LXI (Sears)
36, 37, 42, 44, 45, 47, 49, 80
Magnavox
17, 77, 78, 83
Marantz
21, 33, 35
Marta
47
Memorex
37, 77
Minolta
8, 42
* TV/VCR component
Brand
IR SETUP code
Mitsubishi/MGA
22, 23, 24, 28, 29
Multitech
23, 32, 80
NEC
21, 33, 35
Olympic
77, 78
Optimus
22
Orion
60
Panasonic
16, 17, 77, 78
Pentax
8, 42
Philco
26, 70, 77, 78
Philips
47, 77, 78, 83
Pioneer
78
Quasar
6, 16, 17, 77, 78
RCA/PROSCAN
7, 8, 16, 40, 41, 42, 77, 78, 78*,
83, 101
83, 101
Realistic
22, 36, 37, 77, 80, 88
Sansui
21
Singer
73
Samsung
24, 24*, 32, 32*, 41, 94, 94*
Sanyo
26, 36, 37, 47
Scott
22, 23, 24, 28, 32, 37, 40, 41
Sharp
88, 89
Shintom
73
Signature 2000
80, 89
Sylvania
77, 78, 80, 83
Symphonic
80
Tashiro
47
Tatung
21, 33, 35
Teac
21, 33, 35, 80
Technics
77, 78
Toshiba
7, 40, 49
Wards
37, 47, 88, 89, 95
Yamaha
21, 33, 35, 36
Zenith
95
84
Dubbing only desired scenes – Digital program editing (on a tape)
Step 3: Adjusting the synchronization of the VCR
You can adjust the synchronization of your camcorder and the VCR.
Prepare a pen and paper for notes.
Before operation, eject the cassette from your camcorder (if inserted).
Prepare a pen and paper for notes.
Before operation, eject the cassette from your camcorder (if inserted).
The POWER switch should be set to
.
Operate by touching the panel.
(1) Insert a recordable cassette into the VCR, then set the VCR to recording
pause.
When you select i.LINK in CONTROL, recording pause is not necessary.
When you select i.LINK in CONTROL, recording pause is not necessary.
(2) Select ADJ TEST, then press EXEC.
(3) Select EXECUTE, then press EXEC.
(3) Select EXECUTE, then press EXEC.
IN and OUT are recorded on an image for five times each to calculate the
number values for adjusting the synchronization.
The EXECUTING indicator flashes on the screen. When finished, the
indicator changes to COMPLETE.
number values for adjusting the synchronization.
The EXECUTING indicator flashes on the screen. When finished, the
indicator changes to COMPLETE.
(4) Rewind the tape in the VCR, then start slow playback.
Five opening number of each IN, and closing number of each OUT appear.
Take a note of the opening number value of each IN and the closing number
value of each OUT.
Take a note of the opening number value of each IN and the closing number
value of each OUT.
(5) Calculate the average of five opening number values of IN, and the average
of five closing number values of each OUT.
(6) Select ”CUT-IN”, then press EXEC.
(7) Select the average number value of IN, then press EXEC.
(7) Select the average number value of IN, then press EXEC.
The calculated start position for recording is set.
(8) Select ”CUT-OUT”, then press EXEC.
(9) Select the average number value of OUT, then press EXEC.
(9) Select the average number value of OUT, then press EXEC.
The calculated stop position for recording is set.
(10) Press
RET. to execute.
Click on the first or last page to see other DCR-TRV60 / DCR-TRV60E / DCR-TRV70 (serv.man3) service manuals if exist.