DOWNLOAD Sony DCR-TRV340 Service Manual ↓ Size: 11.4 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV340
Pages
127
Size
11.4 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / BRAZIL
File
dcr-trv340.pdf
Date

Sony DCR-TRV340 Service Manual ▷ View online

5-14
DCR-TRV340
4. 8 Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
1C Page Data”.)
Table. 5-1-8.
5. 1C Page Table
Note1:
When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
1C Page Data”.)
Table. 5-1-9.
00 to 18
19
20 to 34
35
36 to 49
4A
4B to 79
7A
7B
7C
7D
7E
7F
80
81
82
83
84 to 89
8A
8B
8C
8D
8E
8F
90
91
92
93
94 to A3
08
00
46
01
02
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Serial No. input
Fixed data-1
Address
Remark
Initial value
00 to 49
4A
4B to FF
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
5-15
DCR-TRV340
1-2-5.
INITIALIZATION OF E, F, 1F PAGE DATA
Note:
When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the E, F, 1F Page Data
Note1: If “Initializing the E, F, 1F Page Data” is performed, all
data of the E page, F page and 1F page will be initialized.
(It is impossible to initialize a single page.)
Note2:
If the E, F, 1F page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F, 1F page data
2) 27MHz origin osc. Adj.
3) Camera system adjustments
Note3:
The power supply voltage must be 6.1 ± 0.1Vdc.
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
1F
Adjusting Address
00 to D9
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
2D
Set the data, and press PAUSE
button.
4
6
03
01
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
2
00
29
Set the data
7
2
01
29
Set the data, and press the PAUSE
button.
8
Perform “Modification of E, F, 1F
Page Data”.
2. Modification of E, F, 1F Page Data
If the E, F, 1F page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1F page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1F page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 1F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
3. F Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”.)
00 to 0F
10 to 11
12
13 to 16
17
18
19
1A to 1D
1E
1F
20 to 29
2A
2B
2C
2D
2E
2F
30 to 32
33
34
35
36 to 39
80
81
5D
8A
80
7A
4D
3E
64
59
96
7A
22
27
Fixed data-1
27MHz origin osc. Adj.
Fixed data-1
HALL adj.
Fixed data-1
AWB & LV standard data input
Fixed data-1
AWB & LV standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Address
Remark
Initial value
5-16
DCR-TRV340
Table. 5-1-10.
Table. 5-1-12.
3A
3B
3C to 45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57 to 5B
5C
5D
5E
5F to 8D
8E
8F to 93
94
95 to 99
9A
9B to C7
C8
C9 to D6
D7
D8 to ED
EE
EF to F6
F7
F8 to FF
00
F1
2A
18
37
0D
13
08
00
00
00
00
6E
19
00
19
04
00
00
00
Color reproduction adj.
Fixed data-1
Flange back adj.
Fixed data-1
Fixed data-2
Optical axis adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
4. E Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”.)
00 to 05
06
07
08 to 35
36
37 to 9B
9C
9D
9E
9F
A0
A1
A2 to AA
AB
AC to BE
BF
C0
C1
C2
C3
C4
C5 to E9
EA
EB
EC to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Table. 5-1-11.
5. 1F Page Table
Note1:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”.)
00 to 51
52
53 to 5A
5B
5C to 64
65
66
67 to D8
D9
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Address
Remark
F page
5-17
DCR-TRV340
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are
satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
1. HALL Adjustment
For detecting the position of the lens iris, adjust AMP gain and
offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
17, 18, 19
Specified Value 1
89 to 8D
Specified Value 2
15 to 19
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
IRIS display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
8B
Set the data.
3
6
95
17
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note3)
6
6
01
00
Set the data, and press PAUSE
button.
Note3:
The adjustment data will be automatically input to page: F, address:
17, 18, 19.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value 2.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
0
03
00
Set the data.
4
6
01
00
Set the data, and press PAUSE
button.
5
0
01
00
Set the data.
RadarW
RadarW
RadarW
Page of 127
Display

Click on the first or last page to see other DCR-TRV340 service manuals if exist.