5-30
DCR-TRV340
2. PSIG Gray Adjustment (PD-160 board)
Set the uniformity improvement signal to an appropriate level.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 4 of CN5502 (PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
66
Specified Value
A = 5.00 ± 0.1V
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
66
Change the data and set the PSIG
signal level (A) to the specified
value.
(The data should be “00” to “7F”)
3
C
66
Press PAUSE button.
4
0
01
00
Set the data.
3. RGB AMP Adjustment (PD-160 board)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 3 of CN5502 (VG)
Ext. trigger: Pin 4 of CN5502  (PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
64
Specified Value
A = 7.68 ± 0.05V
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
64
Change the data and set the
voltage (A) between the reversed
waveform pedestal and non-
reversed waveform pedestal to the
specified value.
3
C
64
Press PAUSE button.
4
0
01
00
Set the data.
Fig. 5-1-17.
A
2H
Pedestal
Pedestal
A
2H
Fig. 5-1-18.
5-31
DCR-TRV340
4. Black Limit Adjustment (PD-160 board)
Set the dynamic range of the LCD driver to an appropriate level. If
deviated, the LCD screen will become blackish or saturated
(whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 4 of CN5502 (PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
65
Specified Value
A = 8.30 ± 0.08V
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
C4
61
Set the data.
3
3
C5
58
Set the the data.
4
C
65
Change the data and set the PSIG
signal amplitude (A) to the
specified value.
(The data should be “00” to “0F”.)
5
C
65
Press PAUSE button.
6
3
C4
00
Set the data.
7
3
C5
00
Set the data.
8
0
01
00
Set the data.
9
Check that the specified value of
“RGB AMP Adjustment” is
satisfied.
5. Contrast Adjustment (PD-160 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 3 of CN5502 (VG)
Ext. trigger: Pin 4 of CN5502  (PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
69
Specified Value
A = 2.72 ± 0.05V
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
69
Change the data and set the
voltage (A) between the 100 IRE
and 0 IRE (pedestal) to the
specified value.
(The data should be “00” to “7F”.)
3
C
69
Press PAUSE button.
4
0
01
00
Set the data.
A
V
Fig. 5-1-19.
100 IRE
Pedestal
A
2H
Fig. 5-1-20.
5-32
DCR-TRV340
6. Center Level Adjustment (PD-160 board)
Set the video signal center level of LCD panel to an appropriate
level.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 3 of CN5502 (VG)
Measuring Instrument
Digital voltmeter
Adjustment Page
C
Adjustment Address
6A
Specified Value
A = 7.00 ± 0.03Vdc
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
6A
Change the data and set the DC
voltage (A) to the specified value.
(The data should be “00” to “7F”.)
3
C
6A
Press PAUSE button.
4
0
01
00
Set the data.
7. V-COM Adjustment (PD-160 board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
C
Adjustment Address
63
Specified Value
The brightness difference between the
section A and section B is minimum.
Note1:
This adjustment should be carried out upon completion of the
following adjustments.
RGB AMP Adjustment
Black Limit Adjustment
Contrast Adjustment
Center Level Adjustment
Note2:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
63
Change the data so that the
brightness of the section A and
that of the section B is equal.
(The data should be “00” to “3F”.)
3
C
63
Subtract 2 from the data.
4
C
63
Press PAUSE button.
5
0
01
00
Set the data.
Fig. 5-1-21.
A
A
A
A
B
B
B
B
5-33
DCR-TRV340
8. White Balance Adjustment (PD-160 board)
Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
67, 68
Specified Value
The LCD screen should not be colored.
Note1:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC5501
Note2:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
67
7E
Set the data, and press PAUSE
button.
3
C
68
6C
Set the data, and press PAUSE
button.
4
C
68
Check that the LCD screen is not
colored. If not colored, proceed to
step 10.
5
C
67
Change the data so that the LCD
screen is not colored.
6
C
67
Press PAUSE button.
7
C
68
Change the data so that the LCD
screen is not colored.
8
C
68
Press PAUSE button.
9
C
68
If the LCD screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.
Page of 127