DOWNLOAD Sony DCR-TRV340 Service Manual ↓ Size: 11.4 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV340
Pages
127
Size
11.4 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / BRAZIL
File
dcr-trv340.pdf
Date

Sony DCR-TRV340 Service Manual ▷ View online

5-10
DCR-TRV340
1-2-2.
INITIALIZATION OF A, D PAGE DATA
(DCR-TRV340)
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the A, D Page Data
Note1: If “Initializing the A, D Page Data” is performed, all data
of the A page and D page will be initialized. (It is
impossible to initialize a single page.)
Note2:
If the A, D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of A, D page data
Note3:
The power supply voltage must be 6.1 ± 0.1Vdc.
Adjusting page
D
Adjusting Address
10 to 67
Adjusting page
A
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data
2
0
10
00
Set the data
3
7
03
00
Set the data
4
7
00
28
Set the data
5
7
01
28
Set the data, and press the PAUSE
button.
6
7
02
Check that the data changes to
“01”
7
2
00
29
Set the data
8
2
01
29
Set the data, and press the PAUSE
button.
9
Perform “Modification of A, D
Page Data”.
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, D Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of A, D page data”, check that the data of the “Fixed
data-2” addresses of D page are same as those of the same model of
the same destination.
1) The self-diagnosis code “E: 20:00” is displayed on the LCD
screen.
2) The power is shut off so that unit cannot operate.
3. D Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”.)
Table. 5-1-3.
4. A Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”.)
Table. 5-1-4.
00 to 0F
10
11 to 15
16
17 to 21
22
23
24
25
26
27 to 29
2A
2B
2C to 36
37
38 to 39
3A
3B to 49
4A
4B
4C
4D
4E
4F to 67
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built
in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built
in the same model.)
Fixed data-1
Address
Remark
Initial value
00 to 0F
10 to 17
18
19 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
5-11
DCR-TRV340
1-2-3.
INITIALIZATION OF B, 1B PAGE DATA
(DCR-TRV340)
Note:
When reading or writing the B page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the B, 1B Page Data
Note1: If “Initializing the B, 1B Page Data” is performed, all data
of the B page and 1B page will be initialized. (It is
impossible to initialize a single page.)
Note2:
If the B, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of B, 1B page data
Note3:
The power supply voltage must be 6.1 ± 0.1Vdc.
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
02
FF
Set the data.
4
5
01
F3
Set the data, and press PAUSE
button.
5
5
00
01
Set the data, and press PAUSE
button.
6
5
02
Check that the data changes to
“00”.
7
2
00
29
Set the data
8
2
01
29
Set the data, and press the PAUSE
button.
9
Perform “Modification of B, 1B
Page Data”.
2. Modification of B, 1B Page Data
If the B, 1B page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the B page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1B page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1B page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B, 1B Page data:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
3. Loader writing inhibit mode setting
When replacing the IC4903 (EEPROM), set the loader writing inhibit
mode.
Setting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
0E
00
Set the data, and press PAUSE
button.
4
5
03
20
Set the data, and press PAUSE
button.
5
5
01
FA
Set the data, and press PAUSE
button.
6
5
00
01
Set the data, and press PAUSE
button.
7
5
0E
Check that the data is “01”.
8
2
00
29
Set the data.
9
2
01
29
Set the data, and press PAUSE
button.
4. B Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”.)
Table. 5-1-5.
5. 1B Page Table
Note1:
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”.)
00 to 8C
8D
8E to FF
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
00 to FF Fixed data-1
Address
Remark
Table. 5-1-6.
5-12
DCR-TRV340
1-2-4.
INITIALIZATION OF 8, C, 1C PAGE DATA
Note:
When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 1C Page Data
Note1: If “Initializing the 8, C, 1C Page Data” is performed, all
data of the 8 page, C page and 1C page will be initialized.
(It is impossible to initialize a single page.)
Note2:
If the 8, C, 1C page data has been initialized, following adjustments
need to be performed again.
1) Modification of 8, C, 1C page data
2) Serial No. input
3) Viewfinder system adjustments
4) LCD system adjustments
5) Servo and RF system adjustments
6) Video system adjustments
7) Audio system adjustments
Note3:
The power supply voltage must be 6.1 ± 0.1Vdc.
Adjusting page
8
Adjusting Address
00 to A3
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
10
Set the data.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
2
00
29
Set the data
7
2
01
29
Set the data, and press the PAUSE
button.
8
Perform “Modification of 8, C, 1C
Page Data”.
2. Modification of 8, C, 1C Page Data
If the 8, C, 1C page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1C page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1C page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 1C Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
3. C Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
1C Page Data”.)
00 to 0F
10
11
12
13
14 to 15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23 to 24
25
EE
00
00
00
E0
E0
20
20
25
25
25
3E
3E
CA
99
88
Switching position adj.
Fixed data-1
Hi8/std8 CAP FG duty adj.
Reel FG adj.
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL fo adj.
APC adj.
LPF fo adj.
Fixed data-1
S VIDEO out Y level adj.
Address
Remark
Initial value
5-13
DCR-TRV340
Table. 5-1-7.
26
27
28
29
2A to 2B
2C
2D
2E
2F
30 to 3F
40
41
42
43
44
45
46 to 4B
4C
4D
4E
4F
50
51
52
53
54
55 to 57
58
59
5A
5B to 5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F to 81
82
83 to 85
86
87 to 88
89
8A
8B to AE
AF
B0 to E1
E2
E3
E4 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
E3
A1
20
03
E0
0A
00
50
69
64
A6
94
80
61
76
9D
2B
5C
70
21
9D
08
3D
7E
6C
20
37
00
00
00
00
00
00
00
00
00
00
00
00
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Fixed data-2
PLL fo adj.
Fixed data-1
APC adj.
Fixed data-1
Fixed data-2
Reel FG adj.
Fixed data-1
Hi8/std8 switching position adj.
Fixed data-1
Hi8/std8 AFC fo adj.
Hi8/Std8 Y/C output level set
Fixed data-1
Hi8/std8 AFM 1.5MHz deviation adj.
Hi8/std8 AFM 1.7MHz deviation adj.
Hi8/std8 AFM BPF fo adj.
Fixed data-2
VCO adj. (EVF)
Fixed data-1
RGB AMP adj. (EVF)
Fixed data-1
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
VCO adj. (LCD)
V-COM adj. (LCD)
RGB AMP adj. (LCD)
Black limit adj. (LCD)
PSIG gray adj. (LCD)
White balance adj. (LCD)
Contrast adj. (LCD)
Center level adj. (LCD)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Emergency memory address
Address
Remark
Initial value
Address
Remark
Initial value
C page