5-26
DCR-TRV340
11. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03JA
Type B: ENC03JB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing, re-
adjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
2B00 to 4B00
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
STEADY SHOT (Menu display) ...................................... ON
2)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(SI-032 board SE301)
1
0
03
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value.
Yaw sensor check
(SI-032 board SE302)
3
0
03
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
03
00
Set the data.
2
Move the camcorder, and check
that the steady shot operations
have been performed normally.
RadarW
RadarW
RadarW
5-27
DCR-TRV340
1-4.
ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENT
Note1:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note3:
Switch setting:
LCD panel ........................................................................... Close
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN1108 of VC-276 board.
Connect the Measuring Instruments via the CPC-13 jig (J-6082-
443-A).
The following table shows the Pin No. and signal name of CN1108.
Table 5-1-14.
1. VCO Adjustment (VC-276 board)
Set the VCO free-run frequency. If deviated, the EVF screen will
be blurred.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin qa of CN1108 (VCO)
Measuring Instrument
Frequency counter
Adjustment Page
C
Adjustment Address
51, 52
Specified Value
f = 15734 ± 30Hz
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
51
Change the data and set the VCO
frequency (f) to the specified
value.
3
C
51
Press PAUSE button.
4
C
51
Read the data, and this data is
named D
51
.
5
Convert D
51
 to decimal notation,
and obtain D
51
’. (Note1)
6
Calculate D
52
’ using following
equations (Decimal calculation)
When D
51
’   236
D
52
’ = D
51
’+19
When D
51
’ > 236
D
52
’ = 255
7
Convert D
52
’ to a hexadecimal
number, and obtain D
52
. (Note)
8
C
52
D
52
Set the data, and press PAUSE
button.
9
0
01
00
Set the data.
Note2:
Refer to “Table 5-4-1. Hexadecimal-decimal Conversion Table”.
Pin No.
1
2
3
4
5
6
7
8
9
10
Signal Name
REG GND
N. C.
BPF MONI
N. C.
PB RF
REG GND
N. C.
RF SWP
N. C.
N. C.
Pin No.
11
12
13
14
15
16
17
18
19
20
Signal Name
VCO
EVF VG
RF SWP
N. C.
CAP FG
RF MON
N. C.
REG GND
REG GND
REG GND
Fig. 5-1-14.
CN1108
20
1
Remove the 
CPC lid
5-28
DCR-TRV340
2. RGB AMP Adjustment (VC-276 board)
Set the D range of the RGB driver used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin qs of CN1108 (EVF VG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
54
Specified Value
A = 7.50 ± 0.10V
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
54
Change the data and set the
voltage (A) between the reversed
waveform pedestal and non-
reversed waveform pedestal to the
specified value.
3
C
54
Press PAUSE button.
4
0
01
00
Set the data.
3. Contrast Adjustment (VC-276 board)
Set the level of the VIDEO signal for driving the LCD to the
specified value. If deviated, the screen image will be blackish or
saturated (whitish).
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin qs of CN1108 (EVF VG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
58
Specified Value
A = 2.49 ± 0.10V
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
58
Change the data and set the
voltage (A) between the 100 IRE
and 0 IRE (pedestal) to the
specified value.
(The data should be “00” to “7F”.)
3
C
58
Press PAUSE button.
4
0
01
00
Set the data.
Pedestal
Pedestal
A
2H
100 IRE
Pedestal
A
2H
Fig. 5-1-15.
Fig. 5-1-16.
5-29
DCR-TRV340
1-5.
LCD SYSTEM ADJUSTMENT
Note 1:
The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note 3:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note 4:
Set the LCD BRIGHT (Menu display) to the center.
Set the LCD COLOR (Menu display) to the center.
[Adjusting connector]
Most of the measuring points for adjusting the LCD system are
concentrated in CN5502 of the PD-160 board. Connect the
measuring instruments via the multi CPC jig (J-6082-311-A). The
following table shows the Pin No. and signal name of CN5502.
Table 5-1-15.
1. VCO Adjustment (PD-160 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 8 of CN5502 (HSY)
Measuring Instrument
Frequency counter
Adjustment Page
C
Adjustment Address
61, 62
Specified Value
f = 15734 ± 30Hz
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
61
Change the data and set the VCO
frequency (f) to the specified
value.
3
C
61
Press PAUSE button.
4
C
61
Read the data, and this data is
named D
61
.
5
Convert D
61
 to decimal notation,
and obtain D
61
’. (Note2)
6
Calculate D
62
’ using following
equations (Decimal calculation)
When D
61
’   238
D
62
’ = D
61
’+ 17
When D
61
’ > 238
D
62
’ = 255
7
Convert D
62
’ to a hexadecimal
number, and obtain D
62
. (Note2)
8
C
62
D
62
Set the data, and press PAUSE
button.
9
0
01
00
Set the data.
Note2:
Refer to “Table 5-4-1. Hexadecimal-decimal Conversion Table”.
10
9
1
2
CN5502
Pin No.
1
3
5
7
9
Signal Name
VB
VG
VR
XHD
GND
Pin No.
2
4
6
8
10
Signal Name
XVD OUT
PSIG
MAKER CHECK
XHD OUT
GND
PD-160 board
Page of 127
Display

Click on the first or last page to see other DCR-TRV340 service manuals if exist.